How should cargo tank hatches be protected when the ullage opening is open and the tank NOT gas free?A.With gooseneck ventsB.With warning signsC.With flame screensD.With pressure-vacuum relief valves

How should cargo tank hatches be protected when the ullage opening is open and the tank NOT gas free?

A.With gooseneck vents

B.With warning signs

C.With flame screens

D.With pressure-vacuum relief valves


相关考题:

When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it ______.A.one meter from the tank bottom and one meter below the tank topB.one half the ullage of the tank and one meter below the tank topC.one half the ullage of the tank and one meter above the tank bottomD.at three meter intervals from the tank top to the bottom

You are cleaning the tanks after carrying a cargo of crude oil. Which statement is TRUE?A.Washing water should be recirculated if possible because it has the same electric potential as the cargo tank being cleanedB.The hoses to portable cleaning machines should be disconnected before the machines are removed from the tankC.The principal hazard with steaming cargo tanks is raising the ambient temperature above the flame point of the cargo residueD.Steam cleaning and water washing are both capable of generating electrostatic charges within a tank

You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take?A.Cut in another IG fan to increase gas flowB.Open the pressure control valve until the pressure increasesC.Open the tank isolation valve to the fully open positionD.Reduce the pumping rate

A bonding cable should be connected for cargo operations aboard a tank vessel as soon as the ______.A.Cargo has been loaded or dischargedB.Cargo hose is connectedC.Cargo pumps are startedD.Vessel is ready to handle cargo

What refers to the depth of a petroleum product in a tank ________.A.InnageB.OutageC.ThievageD.Ullage

When a non-volatile cargo is carried in a tank that has not been previously gas freed,then that tank shall ______.A.be purged with hydrocarbon gas prior to loadingB.be gas-freed after loading operationsC.not be maintained in an inert conditionD.be maintained in an inert condition

When a tank is to be gas freed after washing,the concentration of hydrocarbon vapour should be reduced by purging the inerted cargo tank with ______.A.the oxygenB.the gasC.the inert gasD.the hydrocarbon vapour

When referring to quantity of barite in a P-tank,ullage is the ______.A.Distance of the barite surface above the tank bottomB.Percentage of barite in the tankC.Distance of the barite surface below the tank coverD.Total weight of barite in UPC(ullages per centimeter)

Which statement about inert gas pressures in a cargo tank is TRUE ________.A.The pressures of the inert gas in the tank may create excessive pressure at the pump while dischargingB.Gas pressures should be maintained at the highest permissible level throughout the discharging processC.High gas pressures may cause pyrophoric oxidation in the tankD.High gas pressures may cause loss of suction when stripping

What is a cofferdam ________.A.Tube fitted to an ullage holeB.Area the product is loaded intoC.Void or empty space separating two tanksD.Opening in the deck used for cleaning a tank

When cleaning a tank by the Butterworth process,you should begin to pump out the slops ______.A.At the end of the drop scheduleB.When the process is startedC.When the process is finishedD.When the tank is clean

单选题0il product samples should be taken from the().Adock riserBships cargo tanksCshore tank dischargeDAll of the above

单选题When measuring the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,check it().Aone meter from the tank bottom and one meter below the tank topBone half the ullage of the tank and one meter below the tank topCone half the ullage of the tank and one meter above the tank bottomDat three meter intervals from the tank top to the bottom

单选题Petroleum cargo tanks should not be topped off at deck level when loading on a cold day because().Aa subsequent temperature rise will cause the cargo to overflowBair pockets may cause the cargo to bubble out of the ullage holeCthe increased viscosity of the product requires higher loading pressure which increases the chances of a spillDthe tank valve may be stiff and a spill will occur before the valve can be closed

单选题You are cleaning the tanks after carrying a cargo of crude oil. Which statement is TRUE? ()AWashing water should be recirculated if possible because it has the same electric potential as the cargo tank being cleanedBThe hoses to portable cleaning machines should be disconnected before the machines are removed from the tankCThe principal hazard with steaming cargo tanks is raising the ambient temperature above the flame point of the cargo residueDSteam cleaning and water washing are both capable of generating electrostatic charges within a tank

单选题When checking the oxygen content of the cargo tanks prior to loading cargoes requiring vapor recovery,the atmosphere must be sampled().Aone meter from the tank bottom and one meter below the tank topBone half the ullage of the tank and one meter below the tank topCone half the ullage of the tank and one meter above the tank bottomDat three meter intervals from the tank top

单选题The term "load on top" is used on many crude oil carriers, is to provide a method for ().Acalculating the ullage in the cargo tanksBloading ballast by gravityCthe loading of new cargo into the slop tank as a procedure to minimize pollutionDcalculating the ratio of cargo expansion in a cargo tank

单选题In setting the valves on a steam-smothering system on a tank vessel,the master control valve to cargo tanks should be().Aopen and individual tank valves openBopen and the individual tank valves closedCclosed and the individual tank valves closedDclosed and the individual tank valves open

单选题What action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?()AThe tank must be gas freedBThe tank must be ballastedCThe tank must be vented to the atmosphereDThe bypass valve must also be closed

单选题You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take? ()ACut in another IG fan to increase gas flowBOpen the pressure control valve until the pressure increasesCOpen the tank isolation valve to the fully open positionDReduce the pumping rate

单选题A bonding cable should be connected for cargo operations aboards a tank vessel as soon as the().Acargo has been loaded or dischargedBcargo ghose is connectedCcargo pumps are startedDvessel is ready to handle cargo

单选题When fueling has been completed().Athe fuel tank fill pipe should be left open to allow vapors to vent from the tankBthe engine should be started immediately to prevent vapor lock in the fuel lineCall hatches should be opened and all compartments should be ventilatedDopen the fuel line and drain a small amount of gasoline into the bilge to clear the line of sediment

单选题Oil product samples should be taken from the().Adock riserBship's cargo tanksCshore tank dischargeDAll of the above

单选题The sign used to caution persons approaching the gangway of a tank barge during cargo transfer reads().AWarning,Keep Off,Stay ClearBDanger,Do Not BoardCWarning,No Smoking,No Open Lights,No VisitorsDDangerous Cargo Being Transferred

单选题In setting the valves on a steam-smothering system on a tanker,the master control valve to cargo tanks should be().Aopen and individual tank valves openBopen and the individual tank valves closedCclosed and the individual tank valves closedDclosed and the individual tank valves open

单选题Portable fire extinguishers must be provided for the cargo tank area of an unmanned tank barge().Aonly when fully loadedBif one or more tanks are fullCwhen transferring cargoDonly when the barge is being towed

单选题A rectangular fish tank has a base 2 feet wide and 3 feet long. When the tank is partially filled with water, a solid cube with an edge length of 1 foot is placed in the tank. If no overflow of water from the tank is assumed, by how many inches will the level of the water in the tank rise when the cube becomes completely submerged?A1/6B1/2C2D3E4