Electrical wiring on all "T-Boats" must be ______.A.concealed to prevent mechanical damageB.concealed so the boat can be maintained more easilyC.protected from the weatherD.in an accessible place behind the ceiling

Electrical wiring on all "T-Boats" must be ______.

A.concealed to prevent mechanical damage

B.concealed so the boat can be maintained more easily

C.protected from the weather

D.in an accessible place behind the ceiling


相关考题:

机械样板在软件默认样板文件的英文全称为()。 A、Mechanical-DefaultCHSCHSB、Electrical-DefaultCHSCHSC、StructuralAnalysis-DefaultCHNCHSD、DefaultCHSCHS

Operation of the valve control release on a fixed CO2 system must immediately ______.A.release CO2 to the protected spaceB.secure all mechanical ventilation in the protected spaceC.sound the rig’s general alarm signal for a fireD.sound an alarm in the ballast control room

A claim for cargo damages may be held against the shipowner if such damage is the result of failure of the ship's officers to ______.A.ensure the fitness and safety of cargo spacesB.ensure adequate packaging of the cargoC.prevent delays due to quarantine restrictionsD.correct all defects in the ship's construction

The damage to a vessel is over $25,000. Who must notify the nearest Coast Guard Marine Safety or Marine Inspection Office as soon as possible?A.The Master of the vesselB.The Radio OfficerC.The Chief OfficerD.All of the above

All accidents and damage to ship,equipment or personnel,must be ______in the vessel deck log.A.entered intoB.enteredC.entered withD.entered in

Which statement concerning reserve sources of energy for GMDSS is FALSE ________.A.While the ship is at sea,there must be available at all times a supply of electrical energy sufficient to operate the radio installations and to charge any batteries used as part of a reserve source of energyB.Both the VHF and MF/HF installations must be simultaneously suppliedC.A means of ensuring a continuous supply of electrical power must be provided to all GMDSS equipment that could be affected by an interruption in powerD.If a UPS or equivalent is used to supply power to the ship's GPS receiver or other source of positional information,a means must be provided to ensure the continuous supply of the information in the event of a failure to the ship's main or emergency source of power

All casualties such as personnel injuries or illness, oil spills, accidental fire, collision,stranding, and unusually severe weather damage, whether at sea, in port, or in shipyard, must be promptly ______ to the company.A.spokenB.saidC.toldD.communicated

All electrical appliances aboard a vessel should be grounded to ______.A.prevent them from falling when the vessel rollsB.protect personnel from electrical shockC.increase their operating efficiencyD.prevent unauthorized personnel from operating them

What must an administrator do to prevent new telnet users from connecting to the system?()A、rmdev -l /dev/ptsB、touch /etc/nologinC、chdev -l sys0 -a nologinD、chuser -a login=false ALL

单选题In the case of any actual or apprehended loss or damage the carrier and receiver must()all reasonable facilities to each other for inspecting and tallying the goods.AmakeBtakeChaveDgive

单选题All accidents and damage to ship,equipment or personnel,must be()in the vessel deck log.Aentered intoBenteredCentered withDentered in

单选题To prevent vibration damage to the fuel supply line of a diesel engine, you may use ().Aa short length of heavy duty clear plastic tubingBa length of approved flexible nonmetallic hoseCwelded flange connections for all jointsDaluminum piping with expansion loops

单选题When a rescuer finds an electrical burn victim in the vicinity of live electrical equipment or wiring,his first step is to().Aflush water over any burned area of the patientBapply ointment to the burned areas on the patientCget assistance to shut down electrical power in the areaDremove the patient from the vicinity of the live electrical equipment or wiring

单选题Operation of the valve control release on a fixed CO2 system must immediately().Arelease CO2 to the protected spaceBsecure all mechanical ventilation in the protected spaceCsound the rig's general alarm signal for a fireDsound an alarm in the ballast control room

单选题Which statement concerning reserve sources of energy for GMDSS is FALSE().AWhile the ship is at sea,there must be available at all times a supply of electrical energy sufficient to operate the radio installations and to charge any batteries used as part of a reserve source of energyBBoth the VHF and MF/HF installations must be simultaneously suppliedCA means of ensuring a continuous supply of electrical power must be provided to all GMDSS equipment that could be affected by an interruption in powerDIf a UPS or equivalent is used to supply power to the ship's GPS receiver or other source of positional information,a means must be provided to ensure the continuous supply of the information in the event of a failure to the ship's main or emergency source of power

单选题A ground can be defined as an electrical connection between the wiring of a motor and its().Ashunt fieldBcircuit breakerCmetal frameworkDinter-pole

单选题When a ship is fully loaded, it needs to prevent the main engine to be().While a ship is fully empty, it needs to prevent the main engine to be().Aoverspeed;overloadBoverload;overspeedCover mechanical load;over thermal loadDover torque;overspeed

单选题() is a machine by which electrical energy is transformed into mechanical energy.AAn alternatorBAn electric motorCA diesel engineDA main switchboard

单选题Whether a ship is sailing before the wind or sailing in the rough sea, we must reduce the fuel injection of the main engine.For the former one, it aims to prevent the main engine being(), while for the later one, it aims to prevent the main engine being().Aoverspeed;overloadBoverload;overspeedCover torque;overspeedDlow mechanical efficiency;overload

单选题When measuring AC current flow, you must always connect the meter ()Ain series with the power source and loadBin parallel with the power source and loadCinsuring correct polarityDusing the lowest range possible to prevent instrument damage

单选题To prevent the spread of fire by convection you should ().Aremove combustibiles from direct exposureBcool the bulkhead around the fireCclose all openings to the areaDshut off electrical power

单选题Each part of the fire-main system located on an exposed deck must be().Aprotected against freezingBlocked to prevent theftCnumbered sequentiallyDpressurized at all times

单选题The lubrication to the cylinders affected by the fire must be ()to prevent seizure and all scavenge drains must be ()to prevent the discharge of sparks and burning oil from the drains into the engine room.Adecreased;openedBdecreased;shutCincreased;openedDincreased;shut

单选题The master should()necessary precautions to prevent accidents or damage.AdoBtakeCsetDhave

单选题Electrical wiring on all “T-Boats” must be()。Aconcealed to prevent mechanical damageBconcealed so the boat can be maintained more easilyCprotected from the weatherDin an accessible place behind the ceiling

单选题Storage batteries on T-Boats must be located().Ain sight of the main engine(s)Bin a tray lined with suitable material that resists damage from the electrolyteCin locked closets with restricted ventilationDnear the bilge to lower the center of gravity and improve stability

单选题A transformer in an electric circuit serves to ()Agenerate its own electrical powerBtransform electrical energy into mechanical energyCincrease or decrease circuit voltage as requiredDconvert AC current to DC current