单选题Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()ACreate LVM mirrors between LUNsBMPIO is necessary as the device driverCUse separate fibre adapters in the Virtual IO Server for each LUNDVirtual IO Server is a disk subsystem and must control the LUNs behind it

单选题
Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()
A

Create LVM mirrors between LUNs

B

MPIO is necessary as the device driver

C

Use separate fibre adapters in the Virtual IO Server for each LUN

D

Virtual IO Server is a disk subsystem and must control the LUNs behind it


参考解析

解析: 暂无解析

相关考题:

Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()A、Create LVM mirrors between LUNsB、MPIO is necessary as the device driverC、Use separate fibre adapters in the Virtual IO Server for each LUND、Virtual IO Server is a disk subsystem and must control the LUNs behind it

A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A、4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B、Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C、Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D、Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()A、Create two virtual adapters on the client, each one from a separate Virtual IO ServerB、Enable dead gateway detection on the client so that the network traffic can be reroutedC、Have a spare network card on standby in the client in case the Virtual IO Server goes downD、Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

Companycom has a p5 590 that has their production LPAR, their Tivoli Storage Manager (TSM) LPAR, and several other LPARs. What method would provide connectivity between the production LPAR, and the TSM LPAR, but be isolated from the other LPARs in the system without utilizing a Virtual IO Server or physical adapter resources?()A、Use shared memory and semaphores to transfer the data to the TSM LPARB、Provide gigabit Ethernet adapters in each LPAR and run a crossover cableC、Create a Virtual Ethernet between the production server and the TSM LPARsD、Create a Virtual Ethernet between the TSM server LPAR and the non-production LPARs

How can virtual processors be differentiated from dedicated processors from a physical processor viewpoint?()A、Dedicated processors are fractions of whole processors that are dedicated to a single partition. B、Virtual processors are the whole number of concurrent operations that the operating system can use. C、Virtual processors and not dedicated processors are processors used in Virtual IO Server partitions. D、Virtual processors and dedicated processors are interchangeable concepts, both are whole physical processors used in virtual and dedicated LPARs.

A system is being planned with three production partitions, one each for an IBM i, AIX standard edition, and Power Linux applications. One fibre-channel attached TS3100 tape library will be shared between the partitions for backup. Which solution provides tape library sharing with minimum operator intervention?()A、Configure VIO Server Express Edition to control the tape library through one fibre channel card.Assign the library to the production partitions when needed.B、Configure the IBM i partition to own the tape library.Use IBM i virtualization to host a virtual tape libraryconnection to the AIX and Linux partition.Assign the library to the production partitions when needed.C、Configure a fibre channel card for each partition, and a configure fibre switch.Connect the partitions and tape library to the switch.Zone the switch so all partitions can enable the tape when needed and disable the tape when finished.D、Configure AIX to control the tape library through one fibre channel adapter.Use AIX virtualization to host a virtual tape library connection to the IBM i and Linux partitions.Assign the library to the production partitions when needed.

A customer uses third party storage and would like to connect it to a Virtual IO server on a Power 550.  How can the third party storage device drivers be installed? ()A、 Use SUMA to obtain the drivers.B、 Use smitty install on the client partitions.C、 Use oem_setup_env environment in the VIO server.D、 Use cfgmgr to configure the devices within the client partition.

Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

A customer is installing an HMC-managed Power 720 with two partitions, one for Production the other for Testing. They plan to use the Testing partition only occasionally and want to minimize hardware. Which of the following meets these requirements?()A、Create a system profile for each partition. Assign all needed resources as 'required'.B、Define all system resources as 'desired' on the Testing partition. Activate only as needed.C、Create two shared processor pools. Assign the minimal I/O resources required for each partition to the shared pools.D、Create both partitions with minimal 'required' resources, and optional resources as 'desired'. Activate each partition as necessary.

What type of configuration can provide the best availability in a Virtual IO Server environment?()A、Provide multiple paths to all resources through 2 or more Virtual IO ServersB、Mirror all disk resources on the Virtual IO Server to present to the client LPARC、Mirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerD、Trunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

A customer wants to run DB2 on a Power 780 with uncapped partitions. They have licensed DB2 for 32 of the 64 active cores, and will use it in multiple partitions.   How can the customer ensure that the number of licenses purchased for DB2 is not exceeded?()A、Create a 32-core shared processor pool for the DB2 partitions.B、Limit the number of virtual processors on each DB2 partition to 32.C、Use the IBM License Metric Tool to dynamically manage DB2 usage in the partitions.D、Set the ‘Desired Processing Units’ in each DB2 partition profile so that the sum of all partitions equals 32.

A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()A、You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch B、Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch C、Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchD、The NPIV switch will count against the number of domains in a fabric

Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A、Reallocate the Virtual IO Server disks to the user LPARB、Create a stripe-group within the Virtual IO Server to protect against disk failureC、Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD、Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()A、The Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. B、The Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. C、The Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. D、The Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.

单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()AYou can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch BUsing blade servers with the NPIV switch will require more fibre ports on the external fibre switch CStorage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchDThe NPIV switch will count against the number of domains in a fabric

单选题Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()AReallocate the Virtual IO Server disks to the user LPARBCreate a stripe-group within the Virtual IO Server to protect against disk failureCReconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskDCreate a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()AShared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.BVirtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.CShared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.DVirtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

单选题A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()AAsk the customer to confirm which option is best for their environment.BOrder the fibre channel option and purchase a converter later if necessary.COrder both SCSI and fibre channel adapters to cover both potential options.DInform the customer that fibre channel was selected for performance reasons.

单选题Companycom is using shared processor LPARs exclusively, including the Virtual IO Server. The users are complaining about response time. The application LPARs can be heavy processor users. The Virtual IO Server has been measured to be processor constrained. How should the Virtual IO Server's shared processor LPAR be configured?()ACapped and with a lower shareBUncapped and with a lower shareCUncapped and with a higher shareDCapped and with no change in share

单选题Companycom has a p5 595 with no DVD configured on this server. How can they install the Virtual IO Server code?()AFrom the HMCBFrom a NFS mountCFrom a FTP serverDFrom any CD or DVD drive on another server

单选题What type of configuration can provide the best availability in a Virtual IO Server environment?()AProvide multiple paths to all resources through 2 or more Virtual IO ServersBMirror all disk resources on the Virtual IO Server to present to the client LPARCMirror all disk resources on the client LPAR to the shared SCSI on the Virtual IO ServerDTrunk multiple Ethernet adapters on the Virtual IO Server to a single Shared Ethernet Adapter (SEA)

单选题A customer uses third party storage and would like to connect it to a Virtual IO server on a Power 550.  How can the third party storage device drivers be installed? ()A Use SUMA to obtain the drivers.B Use smitty install on the client partitions.C Use oem_setup_env environment in the VIO server.D Use cfgmgr to configure the devices within the client partition.

单选题A system is being planned with three production partitions, one each for an IBM i, AIX standard edition, and Power Linux applications. One fibre-channel attached TS3100 tape library will be shared between the partitions for backup. Which solution provides tape library sharing with minimum operator intervention?()AConfigure VIO Server Express Edition to control the tape library through one fibre channel card.Assign the library to the production partitions when needed.BConfigure the IBM i partition to own the tape library.Use IBM i virtualization to host a virtual tape libraryconnection to the AIX and Linux partition.Assign the library to the production partitions when needed.CConfigure a fibre channel card for each partition, and a configure fibre switch.Connect the partitions and tape library to the switch.Zone the switch so all partitions can enable the tape when needed and disable the tape when finished.DConfigure AIX to control the tape library through one fibre channel adapter.Use AIX virtualization to host a virtual tape library connection to the IBM i and Linux partitions.Assign the library to the production partitions when needed.

单选题Companycom wants to use Virtual SCSI disks to boot multiple operating systems from the same disk. How will the volumes appear in the Virtual IO Server and how will the logical volumes appear in the partition?()AThe Virtual SCSI disks are defined as logical volumes in the Virtual IO Server. The logical volumes appear as real devices (hdisks) in the client partitions. BThe Virtual IO adapters are connected to a virtual host bridge. On the Virtual IO Server they are vdisks, on the client partition, the exported disks are visible as virtual disks. CThe Virtual SCSI disks are represented in the ODM as a bus device whose parent is sysplanar0. Logical volumes will be assigned to the Virtual IO Server and virtual disks, vdisks, in the client partition. DThe Virtual IO adapters are represented as adapter devices with the virtual host bridge as their parent. On the Virtual IO Server they are vdisks attached to vscsi, on the client partition the exported disks are visible as virtual disks.

单选题Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()ACreate two virtual adapters on the client, each one from a separate Virtual IO ServerBEnable dead gateway detection on the client so that the network traffic can be reroutedCHave a spare network card on standby in the client in case the Virtual IO Server goes downDCreate an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

单选题How can virtual processors be differentiated from dedicated processors from a physical processor viewpoint?()ADedicated processors are fractions of whole processors that are dedicated to a single partition. BVirtual processors are the whole number of concurrent operations that the operating system can use. CVirtual processors and not dedicated processors are processors used in Virtual IO Server partitions. DVirtual processors and dedicated processors are interchangeable concepts, both are whole physical processors used in virtual and dedicated LPARs.

单选题Companycom is installing a Virtual IO Server to reduce the number of fibre channel adapters needed for each partition. The customer wants to use disk based copy functions to replicate the data on the LUNs. How can this be accomplished?()ACreate LVM mirrors between LUNsBMPIO is necessary as the device driverCUse separate fibre adapters in the Virtual IO Server for each LUNDVirtual IO Server is a disk subsystem and must control the LUNs behind it