单选题During working, thermostatic expansion valve should be ().Aeither all the way open or all the way closedBnormally fully openCthrottled depending on loadDcontrolled by liquefied pressure

单选题
During working, thermostatic expansion valve should be ().
A

either all the way open or all the way closed

B

normally fully open

C

throttled depending on load

D

controlled by liquefied pressure


参考解析

解析: 暂无解析

相关考题:

When replacing a thermostatic expansion valve sensing bulb, it is necessary toA.apply a light film of oil to increase heat transferB.apply a light film of oil to prevent oxidationC.apply a heavy coating of grease to function as a heat sinkD.carefully coat the device with silicone sealant to reduce the effects of convective cooling

A thermostatic expansion valve is properly controlling evaporator superheat. Adjusting this valve to lower the superheat will result in a/anA.evaporator pressure decreaseB.evaporator coil over-feedC.evaporator capacity increaseD.expansion valve diaphragm rupture

单选题During working of an air compressor, () should be drained.Aoil sumpBoil separatorCoutlet pipeDinlet pipe

单选题If a refrigeration system compressor crankcase is sweating, you should ().Aadd refrigerant to the systemBadjust the thermal expansion valve to the proper settingCadjust the float valve to the proper holding pressureDopen the hand expansion valve

单选题A three-way thermostatic control valve regulates the diesel engine cooling water temperature by passing a portion of the water ().Aaround the engineBaround the coolerCto the expansion tankDoverboard

单选题If the operating element of a thermostatic valve installed in a diesel engine cooling system malfunctions, it may result in ()Aa low level in the engine expansion tankBexcessively high coolant pressureCimproper temperaturesDmalfunctioning of the jacket water heater

单选题A ruptured diaphragm in a thermostatic expansion valve will cause the valve to ().AopenBcloseCremain in its positionDflood the evaporator with refrigerant

单选题The scale trap is located between the ()Aking valve and the expansion valveBsolenoid valve and expansion valveCevaporator and receiverDcompressor and evaporator

单选题What is the function of thermostatic expansion valve in a compression refrigeration system?()AnonexistentBfor controlling pressureCfor controlling superheatDfor controlling the solenoid valve

单选题Thermostatic expansion valve are ().Aeither all the way open or all the way closedBnormally openCthrottled depending on loadDcontrolled by suction pressure

单选题During operation, the ()should check the working condition of the derrick.AforemanBoperatorCopenerDstevedore

单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system

单选题During working of an air compressor, () should be drained.Ainter coolerBcylinderCoutlet pipeDinlet pipe

单选题A thermostatic expansion valve is properly controlling evaporator superheatAdjusting this valve to lower the superheat will result in a/an ().Aevaporator pressure decreaseBevaporator coil over-feedCevaporator capacity increaseDexpansion valve diaphragm rupture

单选题A solenoid valve used in a refrigeration system should be installed ().Awith the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valveBupright, sensing temperature of the box, and upstream of the thermal expansion valveCupright, sensing temperature of the box, and downstream of the thermal expansion valveDupright, sensing heat of the tail coil, and upstream of the thermal expansion valve

单选题A cracked diaphragm in a thermostatic expansion valve will cause the valve to ().Areturn to a neutral positionBflood the evaporatorCopenDclose

单选题Which of the listed statements is correct concerning refrigeration systems?()ADehydrators must be used continuously in a refrigeration systemBA 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hoursCA thermostatic expansion valve is used to control refrigerated space temperatureDThe liquid receiver functions to collect and remove non- condensable gases

单选题The thermostatic valve has a throttling action, that is to say the valve can()Astop the refrigerant from flowingBforce the refrigerant to flowCcause the refrigerant pressure to riseDcause the refrigerant pressure to fall

单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()AAt the designed operating temperature, the liquid refrigerant charge has changed to a vaporBThe liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityCThe sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureDThe sensing bulb is never emptied of liquid refrigerant under normal operating conditions

单选题When the refrigeration demand is small,()Athe expansion valve will move toward the wide open positionBthe expansion valve will move toward the closing positionCthe feeler bulb will conveys the high temperatureDthe superheat degree will raise

单选题After passing through the expansion valve the refrigerant should be in the state of ().AvaporBliquidCsolidDNone of the above is tree

单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().Are-adjust the discharge pressureBclean the expansion valve screenCadd refrigerantDadjust the expansion valve

单选题The low pressure side of a refrigeration system is considered to exist from the ().Aexpansion valve to the compressorBreceiver to the expansion coilCexpansion valve to the evaporatorDcondenser to the expansion valve

单选题Prior to starting most medium-speed propulsion diesel engines, which of the procedures listed should be observed?()AThe expansion tank should be topped offBThe thermostatic water regulating valves should be manually openedCThe fuel filters should be changedDThe engine should be turned over slowly with the indicator cocks open

单选题During the dock repair, each sea valve must be disassembled, cleaned and ground well.Before it reassemble the sealing surface between the valve and the valve seat should be checked by ()Achief engineerBsurveyorCthe engineerDthe technique personnel of the shipyard

单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().Aloose expansion valve control bulbBlow differential setting on the H-PcutoutCblown fuse in the motor circuitDfaulty suction pressure regulator

单选题The jacket water temperature in a diesel engine closed freshwater cooling system is normally controlled by ()Aregulating the level of corrosion inhibitor in the primary cooling systemBthe level of the freshwater expansion tankCvarying the engine load to meet temperature requirementsDthe operation of the thermostatic valve