单选题The low pressure side of a refrigeration system is considered to exist from the ().Aexpansion valve to the compressorBreceiver to the expansion coilCexpansion valve to the evaporatorDcondenser to the expansion valve
单选题
The low pressure side of a refrigeration system is considered to exist from the ().
A
expansion valve to the compressor
B
receiver to the expansion coil
C
expansion valve to the evaporator
D
condenser to the expansion valve
参考解析
解析:
暂无解析
相关考题:
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor
The refrigeration system low pressure cutout switch is actuated by______.A.an electric system managerB.a sensing bulb at the tail coil of the evaporatorC.pressure changes in the suction lineD.failure of the king solenoid valve
What alarm is NOT found on an inert gas system ________.A.Low oxygen alarmB.Low pressure alarmC.Scrubber high water level alarmD.Deck seal low water alarm
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题In a direct expansion type multi-box refrigeration system, the compressor is set up to cycle on and off by the()ApressurestatBhigh pressure cutoutCsolenoid valveDlow pressure cutout switch
单选题The refrigeration system low pressure cutout switch is actuated by ().Aan electric system managerBa sensing bulb at the tail coil of the evaporatorCpressure changes in the suction lineDfailure of the king solenoid valve
单选题In an operating refrigeration system low on refrigerant, a liquid line sight glass will()Abe clearBbe blueCbe light greenDshow bubbles
单选题In a compression refrigeration plant the refrigerant is under low pressure in the () and under high pressure in the ().Acompressor;condenserBcondenser;evaporatorCthrottle valve;evaporatorDevaporator;condenser
单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly
单选题If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().Asystem was overcharged with refrigerantBsystem was low on refrigerantCsuction valves were leaking slightlyDrelief valve was leaking slightly
单选题The only means of removing the latent heat of condensation from a refrigerant in the normal refrigeration cycle is by ().Apassing it through the expansion valveBcondensing refrigerant in the system condenserCpassing the gaseous refrigerant through the heat interchanger on the suction side of the compressorDmaintaining a high pressure on the systems receiver
单选题The presence of air in the condenser of a refrigeration system will () the condensing pressure.AincreaseBreduceCmaintain constantDNone of the above is true
单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively
单选题A liquid indicator sight glass is useful in determining whether or not a refrigeration system is sufficiently chargedIt is generally located in the().Ahigh pressure liquid lineBlow pressure liquid lineChigh pressure vapor lineDlow pressure vapor line
单选题Which cause of following will not lead to refrigeration plant short-cycle?()Alack of refrigerantBrefrigerant with much waterCset defectively low pressure relayDno cooling water
单选题Which instrument is used to predict the approach of a low pressure system().AAnemometerBFathometerCBarometerDThermometer
单选题What separate the high pressure side from the low pressure side in a refrigeration system?()ACondenser and thermal expansion valveBKing and solenoid valvesCCompressor and thermal expansion valveDCondenser and solenoid valve
单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()Asystem is overcharged with refrigerantBsystem is low on refrigerantCdischarge valves are leaking excessivelyDdischarge valves are leaking slightly
单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat
单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().Asub-cooled liquidBhigh temperature liquidCoil saturated liquidDsuperheated vapor
单选题The purpose of the refrigeration system low pressure cutout switch is to ()Aprotect the compressor from liquid flood backBprotect the compressor from low discharge pressureCstart and stop the compressor upon system demandDstart the compressor after a drop in the evaporator pressure
单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().Ain the chill boxBbefore the receiverCon the suction side of the compressorDon the discharge side of the compressor
单选题Sweating of the refrigeration system compressor crankcase is caused by ().Atoo much superheatBinsufficient superheatCsuction pressure too lowDexcessive refrigerant returning to the compressor
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser
单选题Which of the listed components is considered to separate the high pressure side of a refrigeration cycle from the low pressure side of the cycle?()AThe condenser and the expansion valveBThe king valve and the solenoid valveCThe compressor and the expansion valveDThe condenser and the solenoid valve
单选题The presence of bubbles in a refrigeration system liquid line may ().Apromote refrigerant dehydrationBbe absorbed in the receiverCcause low condensing pressureDcarry moisture and lead to corrosion