When building a NIC team (virtual port channel) between a host and a pair of Cisco Nexus 5000 Series Switches that will carry FCoE traffic, what is the maximum number of physical links that can exist in the team?()A、 1B、 2C、 4D、 5E、 16

When building a NIC team (virtual port channel) between a host and a pair of Cisco Nexus 5000 Series Switches that will carry FCoE traffic, what is the maximum number of physical links that can exist in the team?()

  • A、 1
  • B、 2
  • C、 4
  • D、 5
  • E、 16

相关考题:

What are some of the characteristics of a typical VLAN arrangement, found throughout the Ezonexam switched LAN? (Select all that apply)A. VLANs logically divide a switch into multiple, independent switches at Layer 2.B. Trunk links can carry traffic for multiple VLANs.C. VLAN implementation significantly increases traffic due to added trunking information.D. A VLAN can span multiple switches.E. VLANs typically increase the number of switches neededF. VLANs typically decrease the number of switches needed

What are some characteristics of the typical VLAN arrangement?() A. VLANs logically divide a switch into multiple, independent switches at Layer 2.B. Trunk links can carry traffic for multiple VLANs.C. VLAN implementation significantly increases traffic due to added trunking information.D. A VLAN can span multiple switches.E. VLANs extend the collision domain to include multiple switches.F. VLANs typically decrease the number of multiple switches.

In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

Which statement about the Adapter FEX feature on the Cisco Nexus 5000 Series Switches is true?()A、 Adapter FEX is a software feature that can be configured on any CNA as long as the Nexus 5000 is running a version of code that supports Adapter FEXB、 Adapter FEX can be thought of as a way to divide a single physical link into multiple virtual links or channels.C、 Packets on each channel are tagged with an 801.Q header that has a specific source VIFD、 When using a dual-homed NIC on the server, active/standby is not supported. Only active/active is supported.

What is the maximum number of Cisco Catalyst 3750 Series Switches that can be united into a single manageable unit using the Cisco StackWise technology?()A、9B、3C、12D、6

On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()A、 on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basisB、 on all ingress interfaces; to provide independent congestion management and 16 queuesC、 on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress portsD、 on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queuesE、 on all egress interfaces; to be able to use EEE 802.1p CoS

Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A、 LLDPB、 LACPC、 PFCD、 FIP

Virtual PortChannels (vPCs) allow links that are physically connected to two different Cisco switches to appear to a third downstream device as coming from a single device and as part of a single port channel. Which of the following are components of a Virtual PortChannel system? ()A、 Two peer devices: the vPC peers of which one is primary and one is secondary and are part of a vPC domain.B、 A Layer 3 Gigabit Ethernet link called peer-keepalive link to resolve dual-active scenariosC、 A redundant 10 Gigabit Ethernet PortChannel called a peer link to carry traffic from one system to the other when neededD、 vPC member ports forming the PortChannelE、 A dot1q trunk between the vPC peersF、 A management port that can be used as peer-keepalive link to resolve dual-active scenarios.

Which are valid statements about Cisco Virtual Interface Card (VIC)? ()A、 The Cisco VIC can create an unlimited number of Virtual NICsB、 The number of vNICs on the Cisco VIC that can be created is determined by the number of chassis uplinksC、 vNICs are created using software on the host operating systemD、 The host operating system sees a vNIC as a physical PCIe deviceE、 The host operating system sees a vNIC as a sub-interface of a primary NICF、 The Cisco VIC can create 1024 vNICs

Which two statements about SAN port channels configured on Cisco Nexus 5000 Series switches are true? ()  A、 The bring up protocol automatically detects and overrides any misconfiguration.B、 You can manually configure channel groups, or they can be automatically created.C、 Changes in configuration to the SAN port channel interface must also be made to all members of the channel group.D、 The port channel protocol uses the exchange fabric parameters command to communicate across peer ports in an ISL.E、 The port channel protocol ensures that a set of ports is eligible to be part of the same SAN port channel.

What are some of the characteristics of a typical VLAN arrangement?()A、VLANs logically divide a switch into multiple, independent switches at Layer 2.B、Trunk links can carry traffic for multiple VLANs.C、VLAN implementation significantly increases traffic due to added trunking information.D、A VLAN can span multiple switches.E、VLANs typically increase the number of switches neededF、VLANs typically decrease the number of switches needed

Which statement about Cisco Unified Fabric switches is correct? ()   A、 The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B、 The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C、 The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D、 The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E、 The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.

What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode

Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()  A、 A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B、 SAN port channels can include up to 16 interfaces.C、 SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D、 The links in SAN port channels can be connected to different sets of switches.E、 The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.

多选题What are some of the characteristics of a typical VLAN arrangement?()AVLANs logically divide a switch into multiple, independent switches at Layer 2.BTrunk links can carry traffic for multiple VLANs.CVLAN implementation significantly increases traffic due to added trunking information.DA VLAN can span multiple switches.EVLANs typically increase the number of switches neededFVLANs typically decrease the number of switches needed

单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A Only to Cisco Fibre Channel switchesB Only to Cisco Fibre Channel switches in NPIV modeC To any Fibre Channel switchD Directly to storage arraysE Only to Nexus Switches

单选题Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A LLDPB LACPC PFCD FIP

多选题Which are valid statements about Cisco Virtual Interface Card (VIC)? ()AThe Cisco VIC can create an unlimited number of Virtual NICsBThe number of vNICs on the Cisco VIC that can be created is determined by the number of chassis uplinksCvNICs are created using software on the host operating systemDThe host operating system sees a vNIC as a physical PCIe deviceEThe host operating system sees a vNIC as a sub-interface of a primary NICFThe Cisco VIC can create 1024 vNICs

多选题What are some characteristics of the typical VLAN arrangement?()AVLANs logically divide a switch into multiple, independent switches at Layer 2.BTrunk links can carry traffic for multiple VLANs.CVLAN implementation significantly increases traffic due to added trunking information.DA VLAN can span multiple switches.EVLANs extend the collision domain to include multiple switches.FVLANs typically decrease the number of multiple switches.

单选题When building a NIC team (virtual port channel) between a host and a pair of Cisco Nexus 5000 Series Switches that will carry FCoE traffic, what is the maximum number of physical links that can exist in the team?()A 1B 2C 4D 5E 16

多选题A virtual port channel (vPC) allows links that are physically connected to two different Cisco Nexus devices to appear as a single port channel to a third device. Which are the mandatory steps for configuring vPC? ()AEnable feature vPCBDefine domainsCEstablish peer keepalive connectivityDCreate a peer linkEConfigure the peer link as a trunk portFCreate port channels and vPCsGDefine port channel load-balancing methodHMake sure configurations are consistent

多选题Which two statements about SAN port channels configured on Cisco Nexus 5000 Series switches are true? ()AThe bring up protocol automatically detects and overrides any misconfiguration.BYou can manually configure channel groups, or they can be automatically created.CChanges in configuration to the SAN port channel interface must also be made to all members of the channel group.DThe port channel protocol uses the exchange fabric parameters command to communicate across peer ports in an ISL.EThe port channel protocol ensures that a set of ports is eligible to be part of the same SAN port channel.

多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode

多选题Virtual PortChannels (vPCs) allow links that are physically connected to two different Cisco switches to appear to a third downstream device as coming from a single device and as part of a single port channel. Which of the following are components of a Virtual PortChannel system? ()ATwo peer devices: the vPC peers of which one is primary and one is secondary and are part of a vPC domain.BA Layer 3 Gigabit Ethernet link called peer-keepalive link to resolve dual-active scenariosCA redundant 10 Gigabit Ethernet PortChannel called a peer link to carry traffic from one system to the other when neededDvPC member ports forming the PortChannelEA dot1q trunk between the vPC peersFA management port that can be used as peer-keepalive link to resolve dual-active scenarios.

单选题What is the maximum number of Cisco Catalyst 3750 Series Switches that can be united into a single manageable unit using the Cisco StackWise technology?()A9B3C12D6

单选题On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()A on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basisB on all ingress interfaces; to provide independent congestion management and 16 queuesC on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress portsD on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queuesE on all egress interfaces; to be able to use EEE 802.1p CoS

单选题Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()A A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B SAN port channels can include up to 16 interfaces.C SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D The links in SAN port channels can be connected to different sets of switches.E The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.