单选题On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()A on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basisB on all ingress interfaces; to provide independent congestion management and 16 queuesC on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress portsD on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queuesE on all egress interfaces; to be able to use EEE 802.1p CoS

单选题
On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()
A

 on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basis

B

 on all ingress interfaces; to provide independent congestion management and 16 queues

C

 on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress ports

D

 on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queues

E

 on all egress interfaces; to be able to use EEE 802.1p CoS


参考解析

解析: 暂无解析

相关考题:

In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()A、 on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basisB、 on all ingress interfaces; to provide independent congestion management and 16 queuesC、 on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress portsD、 on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queuesE、 on all egress interfaces; to be able to use EEE 802.1p CoS

Which two statements about VACLs on Cisco Nexus 7000 Series Switches are true? ()A、 A single VACL can be shared across two or more VDCs.B、 Use of VACLs requires no special license to be installed.C、 VACLs make use of IP or MAC ACLs.D、 Only options drop and forward are permitted.

Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A、 LLDPB、 LACPC、 PFCD、 FIP

Which Cisco product performs virtualized Ethernet switching within a VMware ESX host?()A、Nexus l000B、Nexus 2000C、Nexus 5000D、Nexus 7000

Which two statements best explain why the Cisco Catalyst 6500 Series of switches best fits in thecore area? ()A、 Cisco Catalyst 6500 Series offer a broad set of access capabilities.B、 Cisco Catalyst 6500 Series eliminate network security threats.C、 Cisco Catalyst 6500 Series handle high amounts of traffic flow.D、 Cisco Catalyst 6500 Series aggregate data from the distribution-area switches.

When building a NIC team (virtual port channel) between a host and a pair of Cisco Nexus 5000 Series Switches that will carry FCoE traffic, what is the maximum number of physical links that can exist in the team?()A、 1B、 2C、 4D、 5E、 16

The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect multiple units?()A、 Cisco Express Catalyst 500 Series switchesB、 Cisco Catalyst 2900 Series switchesC、 Cisco Catalyst 3560 switchesD、 Cisco Catalyst 3700 Series switchesE、 Cisco Catalyst 4500 Series switchesF、 Cisco Catalyst 6500 Series switches

If an enterprise customer required A switch for their branch office access layer, which family of switches would the customer likely choose from?()A、Cisco SFS 3000/7000B、Cisco Catalyst 2000 and 3000C、Cisco Catalyst 4000 and 6000D、Cisco Nexus

Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()A、UCS MangerB、virtual supervisor moduleC、virtual ethernet moduleD、distributed virtual switch

Which statement about Cisco Unified Fabric switches is correct? ()   A、 The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B、 The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C、 The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D、 The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E、 The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.

he Cisco Nexus 1000V Series Switches are virtual machine access switches that are an intelligent software switch implementation for VMware vSphere environments running the Cisco NX-OS Software operating system. Together with the VMware ESX hypervisor, the Nexus 1000V supports Cisco VN-Link server virtualization technology, which provides mobile virtual machine security and network policy for VMware View components, including the DHCP snooping feature. DHCP snooping is disabled on the Nexus 1000V by default. When the DHCP snooping feature is enabled on the Nexus 1000V, what are the default trust settings for the vEthernet and uplink ports?() A、 All vEthernet ports are trusted, and all Ethernet ports such as uplinks and port channels are trusted.B、 All vEthernet ports are not trusted, and all Ethernet ports such as uplinks and port channels are not trusted.C、 All vEthernet ports are trusted and all Ethernet ports such as uplinks and port channels are not trusted.D、 All vEthernet ports are not trusted and all Ethernet ports such as uplinks and port channels are trusted.

The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect?()A、 Cisco Express Catalyst 500 Series switchesB、 Cisco Catalyst 2900 Series switchesC、 Cisco Catalyst 3560 switchesD、 Cisco Catalyst 3700 Series switchesE、 Cisco Catalyst 4500 Series switchesF、 Cisco Catalyst 6500 Series switches

What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode

Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()  A、 A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B、 SAN port channels can include up to 16 interfaces.C、 SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D、 The links in SAN port channels can be connected to different sets of switches.E、 The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.

Which Cisco Catalyst switches fit in the access area?()A、 Cisco Catalyst 2900 Series,Catalyst 7300 Series,and Catalyst 8000 SeriesB、 Cisco Catalyst 2900 Series,Catalyst 3700 Series,and Catalyst SeriesC、 Cisco Catalyst 2700 Series,Catalyst 7300 Series,and Catalyst 8000 SeriesD、 Cisco Catalyst 2700 Series,Catalyst 3700 Series,and Catalyst4500 Series

单选题Which statement about the Adapter FEX feature on the Cisco Nexus 5000 Series Switches is true?()A Adapter FEX is a software feature that can be configured on any CNA as long as the Nexus 5000 is running a version of code that supports Adapter FEXB Adapter FEX can be thought of as a way to divide a single physical link into multiple virtual links or channels.C Packets on each channel are tagged with an 801.Q header that has a specific source VIFD When using a dual-homed NIC on the server, active/standby is not supported. Only active/active is supported.

单选题On Cisco Nexus 5000 Series Switches, where are the virtual output queues implemented, and what is the main purpose of virtual output queues?()A on all ingress interfaces; to ensure maximum throughput on a per-egress, per-CoS basisB on all ingress interfaces; to provide independent congestion management and 16 queuesC on all egress interfaces; so that a congested egress port does not affect traffic directed to other egress portsD on all egress interfaces; to prevent head-of-line blocking by utilizing multiple virtual output queuesE on all egress interfaces; to be able to use EEE 802.1p CoS

单选题Which mechanism do the CNA and the Cisco Nexus 5000 Series Switches use to provide a lossless class of Ethernet traffic?()A LLDPB LACPC PFCD FIP

单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A Only to Cisco Fibre Channel switchesB Only to Cisco Fibre Channel switches in NPIV modeC To any Fibre Channel switchD Directly to storage arraysE Only to Nexus Switches

单选题The following Cisco Catalyst Series switches fit in the access area. Which switches also utilize StackWise technology to address the needs of companies with growing networks by allowing them to connect?()A Cisco Express Catalyst 500 Series switchesB Cisco Catalyst 2900 Series switchesC Cisco Catalyst 3560 switchesD Cisco Catalyst 3700 Series switchesE Cisco Catalyst 4500 Series switchesF Cisco Catalyst 6500 Series switches

多选题Which two Fibre Channel features are not supported in Cisco Nexus 5500 and Nexus 5000 platforms? ()Aport securityBfabric bindingCIVRDport trackingEFICON

单选题Which Cisco Catalyst switches fit in the access area?()A Cisco Catalyst 2900 Series,Catalyst 7300 Series,and Catalyst 8000 SeriesB Cisco Catalyst 2900 Series,Catalyst 3700 Series,and Catalyst SeriesC Cisco Catalyst 2700 Series,Catalyst 7300 Series,and Catalyst 8000 SeriesD Cisco Catalyst 2700 Series,Catalyst 3700 Series,and Catalyst4500 Series

单选题When building a NIC team (virtual port channel) between a host and a pair of Cisco Nexus 5000 Series Switches that will carry FCoE traffic, what is the maximum number of physical links that can exist in the team?()A 1B 2C 4D 5E 16

单选题Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?()A A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces. B SAN port channels can include up to 16 interfaces.C SAN port channels distribute traffic across all links in the port channel when source ID and destination ID load balancing are used.D The links in SAN port channels can be connected to different sets of switches.E The On mode of operation means ports only operate as part of a SAN port channel or remain inactive.

多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode

多选题Which two statements about VACLs on Cisco Nexus 7000 Series Switches are true? ()AA single VACL can be shared across two or more VDCs.BUse of VACLs requires no special license to be installed.CVACLs make use of IP or MAC ACLs.DOnly options drop and forward are permitted.

单选题Which component of the Cisco nexus 1000v monitors the migration of virtual machine during vmotion events?()AUCS MangerBvirtual supervisor moduleCvirtual ethernet moduleDdistributed virtual switch