Since RAM is only active when the computer is on, your computer uses disk to store information even when the computer is off. Which of the following is true?(74).A.When your computer is on, only RAM is used to store information.B.When your computer is on, only disk drives are used to store information.C.When your computer is off, only RAM is used to store information.D.When your computer is off, only disk drives are used to store information.
Examine the CREATE DISKGROUP command used to create a disk group:In which situation would you use this method of disk group creation?() A. When two-way disk mirroring is required for the allocation unitsB. When three-way disk mirroring is required for the allocation unitsC. When using hardware mirroring or RAIDD. When disk mirroring is required for the Automatic Storage Management (ASM) disks
You are the network administrator for Ezonexam.Your Windows 2000 Server computer named Ezonexam1 contains two 36-GB hard disks. Disk 0 and Disk 1. Each disk is configured as a basic disc and has a single 36-GB NTFS partition. Both partitions are backed up to a tape each night. The partition on Disk 1 stores user data. Most users at Ezonexam encrypt their files. Disk 1 fails. You replace it with a new hard disk and create a single NTFS partition.You need to recover the data as quickly as possible while maintaining the security of the files on Disk 1.What should you do?A.Restore the contents of Disk 1 from the most recent tape backup to a second file server. Instruct users to copy their files from the second file server to the new partition.B.Restore the contents of Disk 1 from the most recent tape backup to a second file server. Log on to Ezonexam1 console as a recovery agent. Copy the files from the second file server to the new partition.C.Restore the contents of Disk 1 from the most recent tape backup to the new partition on Ezonexam1. Instruct the users to verify the integrity of their files.D.Restore the contents of Disk 1 from the most recent tape backup to the new partition on Ezonexam1. Run the cipher command to decrypt the files.
Which of the following is true about RADIUSV end or Specific Attribute? ()A、 The RADIUSVendor Specific Attribute type is decimal 26.B、 A radius server that does not understandthevendor-specific information sent by a clientmust reject the authentication request.C、 A vendor can freely choose theVendor-ID it wants to use when implementing Vendor Specific Attributes as long as the same Vendor-ID is used on all of its products.D、 Vendor Specific AttributeMUST include the Length field.E、 In Cisco’s Vendor Specific Attribute implementation, vendor-ID of 1 is commonly referred to as Cisco AV(Attribute Value) pairs.F、 Vendor Specific Attributes use a RADIUS attribute type between 127 and 255.
A large corporation is concerned about the amount of time it takes to back up their main file server. They are also concerned that their IT technician frequently forgets to change the backup tapes, thereby leaving the company open to data loss. Which backup system would solve both problems?()A、 RAIDB、 tape libraryC、 optical storageD、 disk to disk to tape
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()A、Youcan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet SwitchB、Using blade servers with the NPIV switch will require morefibre ports on the external fibre switchC、Storage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.D、The NPIV switch will count against the number of domains in a fabric
Which of the following BEST describes the difference between differential and incremental backups?()A、 An incremental backup requires fewer tapes for restoration than a differential backup. B、 A differential backup tape takes less time than an incremental backup tape.C、 A differential backup requires fewer tapes for restoration than an incremental backup.D、 An incremental backup tape costs less than a differential backup tape.
While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()A、NPIV and vSCSI both require multipathing in VIO Server only. B、NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. C、NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. D、NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.
An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()A、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#B、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameC、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameD、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
After rebooting one Virtual IO (VIO) server in a redundant environment, the following command output from the client partition shows that the path to the shared disk from the rebooted VIO server remains in a failed state. Vio_client1# lspath Failed hdisk0 vscsi0 Enabled hdisk0 vscsi1 What must the administrator do to ensure that the path is automatically restored when a VIO server is brought back into service? ()A、 On both VIO servers, modify the inittab making chdev the last command, so that they will start during VIO server reboot.B、 On both VIO servers, change the following parameters and reboot each of them in turn hcheck_interval =60 hcheck_mode=interactiveC、 On client logical partition, modify the inittab making chdev the last command, so that they will start during client partition reboot.D、 On the client logical partition, change the following parameters and reboot the client hcheck_interval =60hcheck_mode=interactive
A system is being planned with three production partitions, one each for an IBM i, AIX standard edition, and Power Linux applications. One fibre-channel attached TS3100 tape library will be shared between the partitions for backup. Which solution provides tape library sharing with minimum operator intervention?()A、Configure VIO Server Express Edition to control the tape library through one fibre channel card.Assign the library to the production partitions when needed.B、Configure the IBM i partition to own the tape library.Use IBM i virtualization to host a virtual tape libraryconnection to the AIX and Linux partition.Assign the library to the production partitions when needed.C、Configure a fibre channel card for each partition, and a configure fibre switch.Connect the partitions and tape library to the switch.Zone the switch so all partitions can enable the tape when needed and disable the tape when finished.D、Configure AIX to control the tape library through one fibre channel adapter.Use AIX virtualization to host a virtual tape library connection to the IBM i and Linux partitions.Assign the library to the production partitions when needed.
While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()A、NPIV andvSCSI both require multipathing in VIO Server only.B、NPIV requiresmultipathing software on client LPARs, vSCSI requires multipathing software on VIO Server.C、NPIV requiresmultipathing software on VIO Server, vSCSI requires multipathing software on client LPARs.D、NPIV requiresmultipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.
What describes the difference between NPIV and vSCSI in the way fibre-channel attached disk and tape are presented when VIO Server is used?()A、NPIV presents Virtual HBA addresses and vendor specific information for disk and tape devices.vSCSI presents generic disk and tape device interfaces.B、NPIV presents generic disk and tape device interfaces on virtual HBA addresses.vSCSI presents HBA addresses as SCSI with vendor specific information for disk and tape devices.C、NPIV presents HBA addresses and vendor specific device information directly to the client partition.vSCSI presents vendor specific disk information and generic tape device interfaces through VIO server.D、NPIV presents virtual HBA addresses with generic device information for SCSI based disk and tape devices.vSCSI presents vendor specific information for disk and tape device devices attached via SCSI hardware interfaces.
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()A、You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch B、Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch C、Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchD、The NPIV switch will count against the number of domains in a fabric
You have a file server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2). You need to implement a backup schedule on Server1 to meet the following requirements: ·Everyday, back up all files and folders to disk. ·Every Friday, back up all files and folders to tape. ·Every Sunday, Tuesday, and Thursday, back up only the files and folders that have changed since the previous Friday’s backup to tape. Which backup jobs should you create? ()A、·a normal backup to disk everyday ·a normal backup to tape on Friday ·a differential backup to tape on Sunday, Tuesday, and ThursdayB、·a normal backup to disk everyday ·a normal backup to tape on Friday ·an incremental backup to tape on Sunday, Tuesday, and ThursdayC、·a copy backup to disk everyday ·a normal backup to tape on Friday ·a differential backup to tape on Sunday, Tuesday and, ThursdayD、·a copy backup to disk everyday ·a normal backup to tape on Friday ·an incremental backup to tape on Sunday, Tuesday and, Thursday
单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()AYou can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch BUsing blade servers with the NPIV switch will require more fibre ports on the external fibre switch CStorage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switchDThe NPIV switch will count against the number of domains in a fabric
单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()AYoucan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet SwitchBUsing blade servers with the NPIV switch will require morefibre ports on the external fibre switchCStorage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.DThe NPIV switch will count against the number of domains in a fabric
单选题A large corporation is concerned about the amount of time it takes to back up their main file server. They are also concerned that their IT technician frequently forgets to change the backup tapes, thereby leaving the company open to data loss. Which backup system would solve both problems?()A RAIDB tape libraryC optical storageD disk to disk to tape
单选题After rebooting one Virtual IO (VIO) server in a redundant environment, the following command output from the client partition shows that the path to the shared disk from the rebooted VIO server remains in a failed state. Vio_client1# lspath Failed hdisk0 vscsi0 Enabled hdisk0 vscsi1 What must the administrator do to ensure that the path is automatically restored when a VIO server is brought back into service? ()A On both VIO servers, modify the inittab making chdev the last command, so that they will start during VIO server reboot.B On both VIO servers, change the following parameters and reboot each of them in turn hcheck_interval =60 hcheck_mode=interactiveC On client logical partition, modify the inittab making chdev the last command, so that they will start during client partition reboot.D On the client logical partition, change the following parameters and reboot the client hcheck_interval =60hcheck_mode=interactive
单选题While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()ANPIV and vSCSI both require multipathing in VIO Server only. BNPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. CNPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. DNPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.
单选题Which of the following BEST describes the difference between differential and incremental backups?()A An incremental backup requires fewer tapes for restoration than a differential backup. B A differential backup tape takes less time than an incremental backup tape.C A differential backup requires fewer tapes for restoration than an incremental backup.D An incremental backup tape costs less than a differential backup tape.
多选题Which of the following is true about RADIUSV end or Specific Attribute? ()AThe RADIUSVendor Specific Attribute type is decimal 26.BA radius server that does not understandthevendor-specific information sent by a clientmust reject the authentication request.CA vendor can freely choose theVendor-ID it wants to use when implementing Vendor Specific Attributes as long as the same Vendor-ID is used on all of its products.DVendor Specific AttributeMUST include the Length field.EIn Cisco’s Vendor Specific Attribute implementation, vendor-ID of 1 is commonly referred to as Cisco AV(Attribute Value) pairs.FVendor Specific Attributes use a RADIUS attribute type between 127 and 255.
单选题You have a file server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2).You need to implement a backup schedule on Server1 to meet the following requirements:·Everyday, back up all files and folders to disk.·Every Friday, back up all files and folders to tape.·Every Sunday, Tuesday, and Thursday, back up only the files and folders that have changed since theprevious Friday’s backup to tape.Which backup jobs should you create?()A·a normal backup to disk everyday ·a normal backup to tape on Friday ·a differential backup to tape on Sunday, Tuesday, and ThursdayB·a normal backup to disk everyday ·a normal backup to tape on Friday ·an incremental backup to tape on Sunday, Tuesday, and ThursdayC·a copy backup to disk everyday ·a normal backup to tape on Friday ·a differential backup to tape on Sunday, Tuesday and, ThursdayD·a copy backup to disk everyday ·a normal backup to tape on Friday ·an incremental backup to tape on Sunday, Tuesday and, Thursday
单选题A system is being planned with three production partitions, one each for an IBM i, AIX standard edition, and Power Linux applications. One fibre-channel attached TS3100 tape library will be shared between the partitions for backup. Which solution provides tape library sharing with minimum operator intervention?()AConfigure VIO Server Express Edition to control the tape library through one fibre channel card.Assign the library to the production partitions when needed.BConfigure the IBM i partition to own the tape library.Use IBM i virtualization to host a virtual tape libraryconnection to the AIX and Linux partition.Assign the library to the production partitions when needed.CConfigure a fibre channel card for each partition, and a configure fibre switch.Connect the partitions and tape library to the switch.Zone the switch so all partitions can enable the tape when needed and disable the tape when finished.DConfigure AIX to control the tape library through one fibre channel adapter.Use AIX virtualization to host a virtual tape library connection to the IBM i and Linux partitions.Assign the library to the production partitions when needed.
单选题An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()AOn the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#BOn the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameCOn the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameDOn the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
单选题What describes the difference between NPIV and vSCSI in the way fibre-channel attached disk and tape are presented when VIO Server is used?()ANPIV presents Virtual HBA addresses and vendor specific information for disk and tape devices.vSCSI presents generic disk and tape device interfaces.BNPIV presents generic disk and tape device interfaces on virtual HBA addresses.vSCSI presents HBA addresses as SCSI with vendor specific information for disk and tape devices.CNPIV presents HBA addresses and vendor specific device information directly to the client partition.vSCSI presents vendor specific disk information and generic tape device interfaces through VIO server.DNPIV presents virtual HBA addresses with generic device information for SCSI based disk and tape devices.vSCSI presents vendor specific information for disk and tape device devices attached via SCSI hardware interfaces.
单选题While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()ANPIV andvSCSI both require multipathing in VIO Server only.BNPIV requiresmultipathing software on client LPARs, vSCSI requires multipathing software on VIO Server.CNPIV requiresmultipathing software on VIO Server, vSCSI requires multipathing software on client LPARs.DNPIV requiresmultipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.
单选题You are configuring a virtual machine (VM) that is running on a Windows Server 2008 R2 host server. The primary virtual disk is connected to IDE Controller 0. You need to add a virtual disk to the VM without shutting down the VM. What should you do?()AAdd the virtual disk to IDE Controller 0.BAdd the virtual disk to IDE Controller 1.CAdd the virtual disk to an existing SCSI controller.DAdd a virtual network adapter to the VM. Attach an iSCSI disk to the VM through the virtual network adapter.