单选题The most suitable pump for oily water separator feed duties is ().Aa reciprocating pumpBa vane pumpCa centrifugal pumpDa triple screw pump
单选题
The most suitable pump for oily water separator feed duties is ().
A
a reciprocating pump
B
a vane pump
C
a centrifugal pump
D
a triple screw pump
参考解析
解析:
暂无解析
相关考题:
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity
单选题Which of the following pumps will most affect oily water separator performance and give the worst result?()Areciprocating pumpBvane pumpCscrew pumpDcentrifugal pump
单选题Placing a filter on the () of an oily water separator will "polish" the discharge but overloading must be avoided.Asuction sideBdischarge sideCby-pass pipeDsampling pipe
单选题Which of the following pumps is most suitable for an oily water separator?()Areciprocating pumpBvane pumpCmono pumpDaxial-flow pump
单选题The ()is fitted on an oily water separator.Asliding bowl bottomBgravity discCbowlDliquid level detector
单选题Which of the equipment listed is most effective in processing bilge slops for overboard discharge?()A100PPM oily water separatorBAssembling the lube oil purifier as a separator and aligning bilge overboardCA 15PPM oily water separatorDA magnetic duplex strainer
单选题The ()pump is usually used as the bilge feed pump to an oily water separator.AturbineBscrewCvaneDejector
单选题The boiler feed water check valves are located on the ()Afeed pump suction lineBhot wellCshell of the feed heaterDfeed lines to the boiler
单选题Which of the following is wrong about operation of oily water separator?()Afilled with clean water before operationBkeep air cushion in oil collecting space during runningCcheck oil level during runningDclean inner separator with low pressure stream
单选题If found oil when we open low oil level plug of separator, it indicates ()Athe separator is overloadBthe monitor equipment of separator failsCthe discharge pump of separator can not workDthe temperature of oil water is low
单选题When oily water separator is operating, which measure () is wrong.Apay attention to operating parametersBrenew and clean separating units in timeCcheck oil level in separator to prevent overloadDcheck separating effect, if it is bad, flush with large capacity water pump
单选题The pressure difference of the gauge on the oily water separator increases greatly, the reason is()Athe filter is cloggedBbilge suction value is cloggedCsuction value and discharge value of the pump do not open fullyDscrew pump is worn seriously and volumetric efficiency is decreased
单选题In an oily water separator the oil will travel () to the oil collecting spaces.AupwardsBdownwardsCoutwardsDforwards
单选题Prior to entering a cargo pump room, you should ensure that ().Athe forced ventilating system is operatingBthe cargo pumps are securedCno monocarbon gases are presentDthe oily water separator is de-energized
单选题After stopping oily water separator, sea water should be permitted for () minutes,()should be closed after stopping pump to reduce oxidation corrosion of inner wall.A15;inlet valueB15;inlet and outlet valueC30;inlet valueD30;inlet and outlet value
单选题Before the oily water separator put into operation, it should be ()Afilled with bilge waterBfilled with oilCfilled with clean waterDbe emptied
单选题The pump used to send the bilge water into the oily water separator()the mixture because this might create finer oil particles.Ashould agitateBshould not agitateCshould mix upDshould not add up
单选题Oily water separator mis-alarms, the most possible reason is ()Aseparating oil too fastBthe sensor flushed badlyCthe discharge solenoid value out of orderDtoo low heating temperature
单选题Because the flow rate of supply water pump is too large, oily water separator does not work wellWhich of the following is not the reason?()Athe monitoring equipment is out of orderBseparating effect becomes badCinner wall is contaminatedDseparating effect becomes bad and inner wall is contaminated
单选题The time of discharging oil is short, but oily water separator discharges oil frequentlyThe possible reason is ()Athe sensor of low oil level is fully covered by sludgeBthe coarse strainer before the pump in suction system is cloggedCthe screw pump is worn seriously and volumetric efficiency is decreasedDbilge suction value is clogged
单选题The boiler feed pump discharge pressure is higher than the steam drum pressure to ().Aensure feed water flow into the boilerBkeep the steam drum pressure highCprevent water hammer in the feed lineDhelp the feed water flash to steam
单选题Here some oil in the oily water separator, as a result of its lower (), will separate and rise into the oil collection space.AtemperatureBviscosityCdensityDvelocity
单选题If separating effect is not good, we can improve it by ()Aflushing separator with hot waterBincreasing water supply flowCheat oily water properlyDopening manual oil discharge value
单选题In which case is the IOPP Certificate of an inspected vessel NOT invalidated? ()AThe required oily-water separator malfunctionsBThe ship is transferred to Liberian registryCAn annual survey is conducted fifteen months after the date of certificate issuanceDA 15 ppm oily-water separator is replaced by a 100 ppm oily-water separator
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity
单选题Which of the following liquids can ordinarily be discharged overboard without being processed through an oily water separator?()ACargo tank ballastBSegregated ballastCEngine room bilgesDCargo pump room bilges