单选题On a Cisco UCS B250 M2 server that is fully populated with 1333-MHz memory and an E5640 CPU, what is the fastest speed the memory can run at?()A 800 MHzB 900 MHzC 1066 MHzD 1333 MHzE 1666 MHz

单选题
On a Cisco UCS B250 M2 server that is fully populated with 1333-MHz memory and an E5640 CPU, what is the fastest speed the memory can run at?()
A

 800 MHz

B

 900 MHz

C

 1066 MHz

D

 1333 MHz

E

 1666 MHz


参考解析

解析: 暂无解析

相关考题:

What is the appliance port used to connect to in a Cisco Unified Computing System?()A、 Fibre Channel storageB、 UCS C-Series serversC、 NFS storageD、 UCS chassisE、 Other fabric interconnect

On a Cisco UCS B250 M2 server that is fully populated with 1333-MHz memory and an E5640 CPU, what is the fastest speed the memory can run at?()A、 800 MHzB、 900 MHzC、 1066 MHzD、 1333 MHzE、 1666 MHz

On a Cisco UCS B250 server, how many physical DIMM slots make up one logical DIMM?()A、 2B、 3C、 4D、 6E、 12

Which two steps are the result of associating a blade server?()A、The compute node reboots and is then connected to the CMCB、A compute node is assigned to a service profileC、if the association is successful the cisco UCS manager boots the cisco UUOS to configure the compute nodeD、The compute node reboots to reload and then loads NX OS and establishes connections to both the CMC and the IOMs

From the Cisco UCS CLI, how do you verify which uplink ports a blade server is using for its network connectivity?()A、 UCS-A# show pinning border-interfacesB、 UCS-B# show service-profile circuitC、 UCS-B(nxos)# show pinning server-interfacesD、 You must statically configure which uplink the blades should use, or you will not have connectivity.

Due to the internal Fiber Channel over Ethernet architecture of the Cisco UCS ,what does each VSANrequire?()A、it is carried on only 1 vhba per ucs systemB、it has a qos policy in order to maintain traffic priorityC、there is a supporting vsan to carry the fcoe trafficD、there is a dedicated VLAN to carry the FCoEtraffic

Which three roles are predefined in the Cisco UCS system?()A、Server AdminB、Network AdminC、Storage AdminD、Security Admin

Where are Cisco UCS vNICs created?()   A、 In the blade BIOSB、 In the operating systemC、 In the service profileD、 In the card option ROM

Which blade of the ucs solution is best able to accommodate the resource requirements of virtual machine growth?()A、UCS B250 M1 (EXPANDED MERNORY Blade Server)B、UCS B200 M1 (Half-width Blade Server)C、UCS 2100 IOM (IO Module)D、UCS VIC M81KR (Virtual CNA)

Why is a Cisco UCS B250 server unable to support 16-GB DIMMs?()A、 Dual-rank DIMMs are not supported.B、 16-GB DIMMs are too slow.C、 The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GBD、 The memory bus would be too long.E、 The blade would run too hot.

Cisco UCS provides integration interfaces and protocols to support heterogeneous data center environments and supports standard monitoring and event notification systems, providing data to standard enterprise-management tools. Which two of these list the primary Cisco UCS interfaces and industry standard-based read-only interfaces? ()A、 UCS Manager XML API and UCS CLIB、 SNMP, SMASH CLP, and CIM-XMLC、 UCS Manager, DCOS, and Local-mgmtD、 SoL and NX-OSE、 debug-plugin and UCS Manager GUI

Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()A、 The fabric interconnects must be in end-host mode.B、 A pin group must be configured on the server tab in Cisco UCS Manager.C、 In the service profile for Server 1, vNIC 1 must be explicitly assigned to a pin group.D、 Server 1 cannot be configured to meet the requirement. A server can only be manually pinned to a single physical interface and not a port channel because of the LACP load-balancing algorithm.E、 Server 1 cannot be configured to meet the requirement. A server is either manually pinned to an uplink on both fabric interconnects or the server is automatically pinned, but not both.

What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode

A retailer is considering deploying an online transaction application on xSeries to serve their buyers.  The server will need no more than four processors and will run on Red Hat Linux AS.  The storage requirement is for 5TB of usable storage, and the maximum memory requirement is 4GB of RAM.  Which solution will provide the best price and performance while maintaining fault tolerance?()A、An x260 with dual fault tolerant ServeRAID adapters and 12 internal drivesB、An x366 with dual fault tolerant NICs with a single Fibre HBA directly attached to a DS4300 with three EXP710s fully populated with 146GB Fibre DrivesC、An x366 with dual fault tolerant NICs and two Fibre HBAs directly attached to a DS4300 Turbo with three EXP700s fully populated with 146GB drivesD、An x445 server with dual fault tolerant HBAs and a DS4500 with two additional EXP710s fully populated with 146GB Drives

You are configuring a new Microsoft System Center Virtual Machine Manager (VMM) 2008 R2  environment to manage your existing virtual infrastructure. The existing infrastructure includes Windows Server 2008 R2 host servers and VMware ESX host servers. You need to add a VMware ESX host server named Host1 to your VMM environment. What should you do?()A、In the Computer name field of the Add VMware VirtualCenter server dialog box, type the fully qualified domain name (FQDN) of Host1.B、In the Computer name field of the Add VMware VirtualCenter server dialog box, type the fully qualified domain name (FQDN) of the VMware VirtualCenter server that manages Host1.C、In the Add Hosts wizard, select the VMware ESX Server host (any location) option. In the Computer name field, type the fully qualified domain name (FQDN) of Host1.D、In the Add Hosts wizard, select the VMware ESX Server host (any location) option. In the Computer name field, type the fully qualified domain name (FQDN) of the VMware VirtualCenter server that manages Host1.

单选题On a Cisco UCS B250 server, how many physical DIMM slots make up one logical DIMM?()A 2B 3C 4D 6E 12

多选题Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()AThe fabric interconnects must be in end-host mode.BA pin group must be configured on the server tab in Cisco UCS Manager.CIn the service profile for Server 1, vNIC 1 must be explicitly assigned to a pin group.DServer 1 cannot be configured to meet the requirement. A server can only be manually pinned to a single physical interface and not a port channel because of the LACP load-balancing algorithm.EServer 1 cannot be configured to meet the requirement. A server is either manually pinned to an uplink on both fabric interconnects or the server is automatically pinned, but not both.

多选题Which two steps are the result of associating a blade server?()AThe compute node reboots and is then connected to the CMCBA compute node is assigned to a service profileCif the association is successful the cisco UCS manager boots the cisco UUOS to configure the compute nodeDThe compute node reboots to reload and then loads NX OS and establishes connections to both the CMC and the IOMs

单选题From the Cisco UCS CLI, how do you verify which uplink ports a blade server is using for its network connectivity?()A UCS-A# show pinning border-interfacesB UCS-B# show service-profile circuitC UCS-B(nxos)# show pinning server-interfacesD You must statically configure which uplink the blades should use, or you will not have connectivity.

单选题Why is a Cisco UCS B250 server unable to support 16-GB DIMMs?()A Dual-rank DIMMs are not supported.B 16-GB DIMMs are too slow.C The largest DIMM an Intel 55xx or 56xx CPU can address is 32 GBD The memory bus would be too long.E The blade would run too hot.

单选题A retailer is considering deploying an online transaction application on xSeries to serve their buyers.  The server will need no more than four processors and will run on Red Hat Linux AS.  The storage requirement is for 5TB of usable storage, and the maximum memory requirement is 4GB of RAM.  Which solution will provide the best price and performance while maintaining fault tolerance?()AAn x260 with dual fault tolerant ServeRAID adapters and 12 internal drivesBAn x366 with dual fault tolerant NICs with a single Fibre HBA directly attached to a DS4300 with three EXP710s fully populated with 146GB Fibre DrivesCAn x366 with dual fault tolerant NICs and two Fibre HBAs directly attached to a DS4300 Turbo with three EXP700s fully populated with 146GB drivesDAn x445 server with dual fault tolerant HBAs and a DS4500 with two additional EXP710s fully populated with 146GB Drives

多选题Which two Cisco UCS features facilitate easy deployment of server farms?()AcloningBCMCsCIOMsDTemplates

单选题Which blade of the ucs solution is best able to accommodate the resource requirements of virtual machine growth?()AUCS B250 M1 (EXPANDED MERNORY Blade Server)BUCS B200 M1 (Half-width Blade Server)CUCS 2100 IOM (IO Module)DUCS VIC M81KR (Virtual CNA)

单选题Due to the internal Fiber Channel over Ethernet architecture of the Cisco UCS ,what does each VSANrequire?()Ait is carried on only 1 vhba per ucs systemBit has a qos policy in order to maintain traffic priorityCthere is a supporting vsan to carry the fcoe trafficDthere is a dedicated VLAN to carry the FCoEtraffic

多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode

多选题Cisco UCS provides integration interfaces and protocols to support heterogeneous data center environments and supports standard monitoring and event notification systems, providing data to standard enterprise-management tools. Which two of these list the primary Cisco UCS interfaces and industry standard-based read-only interfaces? ()AUCS Manager XML API and UCS CLIBSNMP, SMASH CLP, and CIM-XMLCUCS Manager, DCOS, and Local-mgmtDSoL and NX-OSEdebug-plugin and UCS Manager GUI

单选题What is the appliance port used to connect to in a Cisco Unified Computing System?()A Fibre Channel storageB UCS C-Series serversC NFS storageD UCS chassisE Other fabric interconnect