What is the appliance port used to connect to in a Cisco Unified Computing System?()A、 Fibre Channel storageB、 UCS C-Series serversC、 NFS storageD、 UCS chassisE、 Other fabric interconnect

What is the appliance port used to connect to in a Cisco Unified Computing System?()

  • A、 Fibre Channel storage
  • B、 UCS C-Series servers
  • C、 NFS storage
  • D、 UCS chassis
  • E、 Other fabric interconnect

相关考题:

A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of Fibre Channel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning.Each fabric has a name server and provides other services. Higher redundancy over FC-AL, P2P.Which path selection protocol is used by Fibre Channel fabrics?()A.OSPFB.RIPC.FSPFD.VSANs

In a Cisco Unified Computing System, where are SAN port channels connected to?()A、 Only to Cisco Fibre Channel switchesB、 Only to Cisco Fibre Channel switches in NPIV modeC、 To any Fibre Channel switchD、 Directly to storage arraysE、 Only to Nexus Switches

What is the use of NPV in Cisco Unified Computing Systems? ()    A、 Compatibility with third-party Fibre Channel switchesB、 Faster throughputC、 Reduce domain IDs in a Fibre Channel environmentD、 Support for increased number of VSANsE、 Support for SAN port channels

A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of FibreChannel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning. Each fabric has a name server and provides other services. Higher redundancy over FC-AL,P2P.Which path selection protocol is used by Fibre Channel fabrics?()A、 OSPFB、 RIPC、 FSPFD、 VSANs

Which protocol does the UCS Fabric Interconnect support on port channel uplinks?()A、LACPB、PAgPC、MCPC

Which statement ab0ut VLANs in a Cisco UCS is true?()A、Fabric interconnect can never participate in VTPB、Fabric interconnect supports ISL and 802.1Q trunkingC、The supported range of VLANs is auto-configured by UCSD、VLANs are configured through the Cisco UCS manager. (fabric interconnect may be set up in switch mode)

What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()A、 An interface ’san-port-channel’ in NXOSB、 An interface ’port-channel’ in NXOSC、 An interface ’port-channel’ with ’mode fc’ configuredD、 An interface ’fc-port-channel’ in NXOS

What is the use of an "all configuration" backup in Cisco UCS?()A、 Can be used to migrate from a 6120 to a 6140 and retain the same service profilesB、 Can only be used on the fabric interconnect on which it was createdC、 Can be used to migrate from a 6120 to 6140 and retain system IP addresses and cluster informationD、 Can be used to match firmware versions between 6120 and 6140 during a migration

A Cisco UCS fabric interconnect in end-host mode learns MAC addresses on which port types?()A、 Uplink Ethernet ports or border portsB、 Appliance portsC、 Server portsD、 Fabric portsE、 Backplane portsF、 vEth interfacesG、 A Fabric Interconnect doesn’t learn MAC addresses in End Host mode. Pinning is used instead.

Which statements are true regarding the Cisco UCS fabric failover feature? ()A、 FabricSync is used to synchronize MAC addresses to an adjacent fabric interconnect after a server interface failover.B、 Gratuitous ARPs are sent on fabric interconnect uplinks after a server interface failover. C、 Fabric failover can be used on vNICs and vHBAs.D、 Fabric failover is configured as part of the service profile.E、 Fabric interconnects in end-host mode use fabric failover instead of spanning tree to provide redundancy on uplink ports.

Which statement about Cisco Unified Fabric switches is correct? ()   A、 The Nexus 5000 family of switches does not support vPC when running in either NPV or FCoE NPV mode.B、 The MDS 9100 family of switches is an excellent design choice as a Unified Fabric edge switch. C、 The Nexus 7000 Series Switches can support the NPIV mode of operation, but cannot function as a complete Fibre Channel Forwarder.D、 The Nexus 7000 Series Switches cannot support advanced Cisco Fibre Channel features such as IVR.E、 The MDS family of Cisco Unified Fabric switches supports both the Fibre Channel Forwarder and Fibre Channel Bridge functions.

Which two statements about QoS options in a Cisco UCS environment are true?()A、 The QoS policy assigns a system class to the outgoing traffic for a vNIC or vHBA.B、 Flow-control policies determine whether the uplink Ethernet ports in a Cisco UCS environment send and receive IEEE 802.3x pause frames when the send buffer for a port fills.C、 If no system class is configured as CoS 0, the Fibre Channel system class is used.D、 The user can configure QoS for these system classes: platinum, gold, silver, best effort, Fibre Channel.E、 When configuring a system class, the type of adapter in a server may limit the maximum MTU supported.

Where are SAN Port Channel is created in UCS Manager?()A、 Under the Admin tab on the FIB、 Under the Server tab in the service profileC、 Under the SAN tab on each VSAND、 Under the Admin tab on the chassisE、 Under the SAN tab on the Fabric Interconnect

Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()A、 The fabric interconnects must be in end-host mode.B、 A pin group must be configured on the server tab in Cisco UCS Manager.C、 In the service profile for Server 1, vNIC 1 must be explicitly assigned to a pin group.D、 Server 1 cannot be configured to meet the requirement. A server can only be manually pinned to a single physical interface and not a port channel because of the LACP load-balancing algorithm.E、 Server 1 cannot be configured to meet the requirement. A server is either manually pinned to an uplink on both fabric interconnects or the server is automatically pinned, but not both.

When will an "all configuration" backup be imported into the Cisco UCS Manager?()A、 During the initial configuration from the consoleB、 Once the basic configuration has been appliedC、 To restore the configuration on a secondary fabric interconnectD、 To upgrade the firmware on a replacement fabric interconnect

What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()A、 Cisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesB、 Cisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesC、 Two Cisco UCS 6100 Series or 6200 Series fabric interconnectsD、 Two RJ45 Ethernet cablesE、 The fabric interconnects must be in end-host mode

多选题A Cisco UCS fabric interconnect in end-host mode learns MAC addresses on which port types?()AUplink Ethernet ports or border portsBAppliance portsCServer portsDFabric portsEBackplane portsFvEth interfacesGA Fabric Interconnect doesn’t learn MAC addresses in End Host mode. Pinning is used instead.

单选题Where are SAN Port Channel is created in UCS Manager?()A Under the Admin tab on the FIB Under the Server tab in the service profileC Under the SAN tab on each VSAND Under the Admin tab on the chassisE Under the SAN tab on the Fabric Interconnect

单选题In a Cisco Unified Computing System, where are SAN port channels connected to?()A Only to Cisco Fibre Channel switchesB Only to Cisco Fibre Channel switches in NPIV modeC To any Fibre Channel switchD Directly to storage arraysE Only to Nexus Switches

单选题What is the use of an "all configuration" backup in Cisco UCS?()A Can be used to migrate from a 6120 to a 6140 and retain the same service profilesB Can only be used on the fabric interconnect on which it was createdC Can be used to migrate from a 6120 to 6140 and retain system IP addresses and cluster informationD Can be used to match firmware versions between 6120 and 6140 during a migration

单选题What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()A An interface ’san-port-channel’ in NXOSB An interface ’port-channel’ in NXOSC An interface ’port-channel’ with ’mode fc’ configuredD An interface ’fc-port-channel’ in NXOS

多选题Which statements are true regarding the Cisco UCS fabric failover feature? ()AFabricSync is used to synchronize MAC addresses to an adjacent fabric interconnect after a server interface failover.BGratuitous ARPs are sent on fabric interconnect uplinks after a server interface failover.CFabric failover can be used on vNICs and vHBAs.DFabric failover is configured as part of the service profile.EFabric interconnects in end-host mode use fabric failover instead of spanning tree to provide redundancy on uplink ports.

单选题Which protocol does the UCS Fabric Interconnect support on port channel uplinks?()ALACPBPAgPCMCPC

多选题What is the use of NPV in Cisco Unified Computing Systems? ()ACompatibility with third-party Fibre Channel switchesBFaster throughputCReduce domain IDs in a Fibre Channel environmentDSupport for increased number of VSANsESupport for SAN port channels

单选题What is the appliance port used to connect to in a Cisco Unified Computing System?()A Fibre Channel storageB UCS C-Series serversC NFS storageD UCS chassisE Other fabric interconnect

多选题What is required for Cisco UCS C-Series rack server integration with Cisco UCS Manager?()ACisco UCS Manager 1.3(xx) or later and a pair of Nexus 2248 FEXesBCisco UCS Manager 2.0(2xx) or later and a pair of Nexus 2232 FEXesCTwo Cisco UCS 6100 Series or 6200 Series fabric interconnectsDTwo RJ45 Ethernet cablesEThe fabric interconnects must be in end-host mode

单选题Which statement ab0ut VLANs in a Cisco UCS is true?()AFabric interconnect can never participate in VTPBFabric interconnect supports ISL and 802.1Q trunkingCThe supported range of VLANs is auto-configured by UCSDVLANs are configured through the Cisco UCS manager. (fabric interconnect may be set up in switch mode)