单选题The saturation temperature of the refrigerant must be () that required in the evaporator refrigerated space.AaboveBbelowCequal toDNone of the above

单选题
The saturation temperature of the refrigerant must be () that required in the evaporator refrigerated space.
A

above

B

below

C

equal to

D

None of the above


参考解析

解析: 暂无解析

相关考题:

The temperature of the refrigerant in the evaporator coil depends mostly upon the ___.A.refrigerant pressure in the evaporatorB.cooling water temperature to the condenserC.heat load in the refrigerator compartmentD.solenoid valve in the liquid line

If the superheat value of a thermostatic expansion valve is set too low, the _.A.the suction line will be abnormally cold and liquid may slug back to the compressorB.the suction line will be hot due to a reduced amount of refrigerant returning to the compressorC.the temperature of the refrigerant within the condenser will remain the sameD.the temperature of the refrigerant passing through the sub-cooler will decrease

Sub-cooling is a method of reducing the temperature of the liquid refrigerant below its ______.A.freezing pointB.floc point(浊点)C.condensing temperatureD.compression temperature

Excessive circulation of the lubricating oil with the refrigerant in a refrigeration system will cause______.A.carbon deposits on the compressor suction valvesB.the evaporator temperature to increaseC.rapid corrosion of the thermal expansion valveD.no operating problems

单选题When the temperature of the refrigerant flowing out from the condenser is below the condensing temperature, it is said to be ().AdryBwetCsuper-cooledDsuperheated

单选题When you adjust a thermostatic expansion valve, ().Arefrigerant must be bled off the sensing line before adjustments are madeBall refrigerant must be pumped into the receiver before adjustments are madeCtime must be allowed for conditions to stabilize in the evaporator before further adjustments are madeDall refrigerant must be routed through the dehydrator while changing the superheat setting

单选题An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().Arestriction in refrigerant pipingBair and non-condensable gases in the condenserCwater in the refrigerantDflooding back of liquid refrigerant from the evaporator

单选题Water evaporates or steam condenses at the saturation temperature, which depends upon the pressure, the higher the pressure () the saturation temperature.Athe moreBthe higherCthe lowerDthe highest

单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().Aa shortage of compressor oilBwarm food in the refrigeratorCexcessive condenser cooling waterDa shortage of refrigerant

单选题In a vacuum distillation system, the case is the higher the pressure, ().Athe saturation temperature is higherBthe higher the saturation temperatureCthe higher is the saturation temperatureDthe saturation temperature is more high

单选题Which of the following statements is correct concerning a typical shipboard multi-coil refrigeration system?()AThe liquid receiver functions to collect and remove non-condensable gasesBA thermostatic expansion valve is used to control refrigerated space temperatureCRefrigerant temperature in an evaporator is directly related to refrigerant pressureDDehydrators must be used continuously in a refrigeration system

单选题In a compression refrigeration cycle, the temperature of the liquid refrigerant experiences its greatest decrease in the().AevaporatorBcompressorCexpansion valveDcondenser

单选题The heated feedwater entering any flash chamber of a flash-type evaporator will()Avaporize, with the unflashed water remaining at the temperature at which it entered the flash chamberBvaporize, with the unflashed water equalizing to the saturation conditions existing in the flash chamberCvaporize, with the remaining water at the temperature greater than it entered the flash chamberDboil, allowing steam bubbles to rise through the brine at the bottom of the flash chamber

单选题The temperature of the refrigerant in the evaporator coil depends mostly upon the ().Arefrigerant pressure in the evaporatorBcooling water temperature to the condenserCheat load in the refrigerator compartmentDsolenoid valve in the liquid line

单选题If the capacity of the refrigeration compressor is too large, the saturation temperature will ().AriseBfallCbe maintained constantDNone of the above

单选题In a diesel engine jacket water cooler, with seawater cooling the fresh water, the()Asea water temperature must never be warmer than 40℃Bjacket water pressure should always be greater than the sea water pressureCjacket water temperature must always be less than 60℃Djacket water pressure must always be less than the sea water pressure

单选题A refrigerant with oil in solution has a ().Ahigher boiling temperature for a given pressure than does a pure refrigerantBlower boiling temperature for a given pressure than does a pure refrigerantCboiling pressure equal to that of a pure refrigerant at a given pressureDboiling point will not be affected by entrained oil

单选题In terms of pressure and temperature in the refrigerant in the compressor, what happens to the primary?()Aits pressure and temperature are both loweredBits pressure and temperature are both raisedCits pressure is lowered and its temperature is raisedDits pressure is raised and its temperature is lowered

单选题Both the temperature and the pressure of the refrigerant are increased in the ().AcompressorBcondenserCevaporatorDexpansion valve

单选题The refrigerant leaves the evaporator of a refrigeration system as a low pressure ().Asub-cooled liquidBhigh temperature liquidCoil saturated liquidDsuperheated vapor

单选题Which of the following conditions must exist for heat to flow from one object to another?()AThe two objects must be in physical contactBThe two objects must be the same sizeCThere must be an existing temperature differentialDThere must be an existing weight differential

单选题Which of the listed statements is a characteristic of the liquid charged power element used with thermostatic expansion valves?()AAt the designed operating temperature, the liquid refrigerant charge has changed to a vaporBThe liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivityCThe sensing bulb is empty of liquid refrigerant charge at the designed operating temperatureDThe sensing bulb is never emptied of liquid refrigerant under normal operating conditions

单选题For safe storage, the maximum allowable temperature to which refrigerant bottles should be exposed is ().A100℃B125℃C150℃D175℃

单选题The principal purpose of sub-cooling liquid refrigerant prior to its entering the expansion valve is to ().Aincrease the refrigerating effect, by decreasing the amount of flash gasBallow the refrigerant to enter the throttling device in a saturated conditionCincrease the refrigerating effect by increasing the amount of flash gasDminimize the temperature drop of the liquid as it passes through the solenoid valve to the outlet side

单选题Sub-cooling is a method of reducing the temperature of the liquid refrigerant below its ().Afreezing pointBfloc pointCcondensing temperatureDcompression temperature

单选题If the compressor-discharge temperature is higher than the receiver temperature()Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some of the refrigerant from the system

单选题A sight glass is installed in the liquid line to indicate the condition of the refrigerant charge and may also indicate the ().Acondition of the expansion valveBmoisture in the systemCcondition of the compressor suction valvesDcondenser temperature