单选题A System p administrator plans to install a new system with AIX 5.3 TL5 using a NIM server. Which of the following provide post install diagnostics()ASPOTBlpp_sourceCmksysbDinstall CD
单选题
A System p administrator plans to install a new system with AIX 5.3 TL5 using a NIM server. Which of the following provide post install diagnostics()
A
SPOT
B
lpp_source
C
mksysb
D
install CD
参考解析
解析:
暂无解析
相关考题:
The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()A、It is a hardware problem caused by the power failure.B、There is a network problem, most probably with name resolution.C、Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.D、Some filesets may be marked as broken and need to be reinstalled.
An administrator has added a new device to a system and wants to determine if it has been correctly added to the ODM database. Which command would the system administrator use?()A、odmgetB、odmaddC、odmshowD、odmcreate
A System p administrator plans to install a new system with AIX 5.3 TL5 using a NIM server. Which of the following provide post install diagnostics()A、SPOTB、lpp_sourceC、mksysbD、install CD
The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()A、System rebootB、Reseat the memoryC、Install the latest firmwareD、Install the latest driver
A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system. How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.
A system administrator has been asked to install an APAR but wants to be able to easily remove it. Which install option should be used?()A、applyB、cleanupC、commitD、reject
A System p adminstrator must recover user information from a system that will not successfully boot. Which of the following install methods will accomplish this ()A、PreservationB、MigrationC、New and complete overwriteD、Repair
A system administrator decides to review the system error log after installing new hardware. Which of the following is the correct command to use?()A、errptB、syslogC、prtdiagD、errlogger
A System p administrator has just installed a new technology level, but "oslevel -r" does not show the expected technology level. Which of the following commands would determine which filesets are downlevel()A、lppchkB、instfixC、oslevelD、installp
New AIX systems arrive without a CDROM drive. All systems do not have the system hardware configuration. Which of the following options is the most appropriate way to install AIX on the systems?()A、Install CDROM drives or tape drives on the systems because that is the only way to install AIX.B、Install one system. Take a mksysb from the first system and resotre the mksysb to the remaining systems.C、Install one system. Mirror rootvg onto a disk from each of the remaining systems.D、Setup and NIM master and resources.
A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()A、viB、mkitabC、telinitD、startsrc
How does a system administrator add a new user to a system?()A、mkuserB、cruserC、adduserD、edit /etc/password
Several people in an Information Technology (IT) department are asking for fileset updates that the system administrator received earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone. Which of the following commands will allow the system administrator to copy the images from the CD-ROM to the install directory?()A、smit bffcreate from the target directoryB、tar -xvf /dev/cd0 from the target directoryC、restore -xvqf /dev/cd0 from the target directoryD、mount the cdrom on /cdrom and cp /cdrom/* . from the target directory
A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()A、The ODM is corrupted.B、There is a hardware failure.C、The bosboot command failed.D、Not enough space is available in the filesystems.
A System p distribution customer is very concerned about Reliability, Availability and Serviceability (RAS). They are planning to install several p6 servers in their facilities and want to be able to move an LPAR from one System p to another. Which of the following would accomplish this()A、System p servers using similar SAN storageB、System p servers must share an HMCC、System p servers must have the same level HMCD、System p servers with VIOS
A System p administrator in a manufacturing customer plans to migrate an AIX 5.2 system to a new LPAR on an existing System p using VIOS. Which of the following must be completed prior to this migration ()A、Upgrade system firmware to latest levelB、Upgrade to AIX 5.3C、Upgrade HMC to version 6.1D、Convert rootvg filesystems to JFS2
A customer currently has five partitioned POWER4 systems and is adding new systems. When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()A、Order a new HMC to support the p5 system.B、Attach the new p5 system to the existing HMC.C、Upgrade the existing HMC to accommodate both the POWER4 and p5 systems.D、Do nothing. This system does not require an HMC.
Which of the following BEST describes the initial process of setting up a new operating system from a CD-ROM? ()A、Format a partition, install device drivers, and install the operating system.B、Create a partition, format the partition, and install the operating system.C、Install the operating system, create a partition, and install device drivers.D、Install the operating system, install device drivers, and create a partition.
单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system. How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.
单选题The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()AIt is a hardware problem caused by the power failure.BThere is a network problem, most probably with name resolution.CSine the system was never rebooted, devices are marked defined instead of available and need to be activated.DSome filesets may be marked as broken and need to be reinstalled.
单选题A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()AThe ODM is corrupted.BThere is a hardware failure.CThe bosboot command failed.DNot enough space is available in the filesystems.
单选题everal people in an finance customer IT department are asking for fileset updates that the system administrator received from IBM earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone. Which of the following commands will allow the system administrator to copy the images from an IBM update CD-ROM to the install directory()Asmit bffcreate from the target directoryBtar -xvf /dev/cd0 from the target directoryCrestore -xvqf /dev/cd0 from the target directoryDmount the cdrom on /cdrom and run cp /cdrom/* . from the target directory
单选题Which of the following BEST describes the initial process of setting up a new operating system from a CD-ROM? ()AFormat a partition, install device drivers, and install the operating system.BCreate a partition, format the partition, and install the operating system.CInstall the operating system, create a partition, and install device drivers.DInstall the operating system, install device drivers, and create a partition.
单选题A System p adminstrator must recover user information from a system that will not successfully boot. Which of the following install methods will accomplish this ()APreservationBMigrationCNew and complete overwriteDRepair