单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()Afuel oil supply temperature is normalBburner electrode is incorrectly positionedCfuel/air ratio is incorrectDignition current is too low
单选题
A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()
A
fuel oil supply temperature is normal
B
burner electrode is incorrectly positioned
C
fuel/air ratio is incorrect
D
ignition current is too low
参考解析
解析:
暂无解析
相关考题:
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum
单选题Proper combustion in a boiler would be indicated by ().Ayellowish flameBgolden yellow flameCwhite flameDbrilliant white flame
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished
单选题Improper maintenance of an automatic auxiliary boiler oil burner could result in ().Afuel pump failureBfan motor failureCincreased feedwater consumptionDdecreased boiler efficiency
单选题During waste clothes being charged into an incinerator, the auxiliary burner().Ashould be stopped manuallyBkeeps the combustion as usualCwould be cut off by an interlockDwould replace the waste oil burner and keep going on
单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()Awater in the fuel oilBbroken high tension leadsCincorrect electrode settingDfull fuel pressure at the nozzle
单选题The water in an auxiliary boiler should be tested daily for ().Adissolved oxygenBchloridesCsludgeDdissolved nitrogen
单选题A dazzling white burner flame in the boiler furnace indicates ().Aproper combustionBwater in the fuelCexcess airDcold fuel oil
单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished
单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().AwaterBvoltageCfuel pressureDsteam pressure
单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain
单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()Acarbon deposits on the flame scannerBhigh fuel oil temperatureClow fuel oil viscosityDhigh steam pressure
单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate re-firing of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdrum level to stabilize
单选题A burner responsible for producing black smoke in an automatic auxiliary boiler, would be caused by a ()Adefective solenoid valveBdirty fuel nozzleCgrounded high tension leadDfaulty ignition cable connector
单选题The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()Aprecipitate silica from solutionBreduce corrosion in the heating coilCprevent clogging and erosion in the coilDmaintain zero water hardness
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()Aa burned out solenoid in the oil supply valveBhigh temperature excess airCincorrectly setting the hot-well dump valveDan incorrectly positioned burner snubber realy
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces
单选题Heavy soot accumulations in an auxiliary boiler could be caused by()Awater in the fuel oilBexcessive cyclingChigh fuel oil pressureDimproper burner maintenance
单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()Aincorrect electrode settingBincorrect nozzle positionCclogged fuel nozzleDbroken high tension lead
单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity
单选题Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().A10B7C4D1
单选题After a normal, or safety shutdown, automatic combustion control systems for an auxiliary boiler are designed to prevent the immediate refiring of a burner in order for the ().Afurnace to be re-purgedBelectric charge to buildup in the igniterCfuel pump to restartDdram level to stabilize
单选题The furnace of an oil fired boiler should be () before the operating burner is lit.Afilled with waterBpurgedCcleared of airDNone of the above is true
单选题A dazzling white burner flame in the boiler furnace indicates ().Ano combustionBdeposits in the fuelCexcessive air in the fuelDcold fuel oil