单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()Aincorrect electrode settingBincorrect nozzle positionCclogged fuel nozzleDbroken high tension lead
单选题
Flame failure in an automatically fired auxiliary boiler can from a/an ()
A
incorrect electrode setting
B
incorrect nozzle position
C
clogged fuel nozzle
D
broken high tension lead
参考解析
解析:
暂无解析
相关考题:
The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler() A.salinity is abnormallyB.high steam demand is tooC.feed-water flow is lowD.water level is abnormally low
The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ______.A.steam demand is highB.salinity is highC.safety valve simmers(爆发)D.burner flame is extinguished
单选题Auxiliary diesel engines can be automatically shut down as a result of ()Alow lube oil temperatureBlow lube oil pressureChigh exhaust temperatureDhigh cooling water pressure
单选题The concentration of total dissolved solids in the water of an auxiliary boiler can increase as a result of ().Aseawater contaminationBfrequent surface blowsCdissolved oxygen deaerationDfrequent bottom blows
单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum
单选题Too much air in the furnace of an oil-fired boiler would be indicated by ().Ayellowish flameBgolden yellow flameCwhite flameDbrilliant white flame
单选题In the event of a flame failure in an auxiliary water-tube boiler, you must()Arelight the boiler immediately to prevent loss of steam pressureBrelight the fire off the brickwork as the bricks are cherry redCpurge the furnace of any combustible gases before attempting to relight the fireDspeed up the feed pump to prevent dry firing when the burner flame is reestablished
单选题The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().Aoperating the boiler at less than normal water levelBinstalling fins on the firesides of water-tubesCincreasing the amount of excess air to the burnersDtreating the boiler water with chemical oxygen scavengers
单选题A smoking burner with a pulsating flame in auxiliary boiler, is an indication that the()Afuel oil supply temperature is normalBburner electrode is incorrectly positionedCfuel/air ratio is incorrectDignition current is too low
单选题Failure of the burner flame in an auxiliary boiler would probably be a result of()Awater in the fuel oilBbroken high tension leadsCincorrect electrode settingDfull fuel pressure at the nozzle
单选题In the event of failure of an auxiliary such as a lubricating pump, the standby pump is started and put on the line automatically“the line” in this sentence refers to()Afuel manifoldBlubricating pipe lineCauxiliary engine pipe lineDgenerator output line
单选题The purpose of the programmed purge cycle on an automatically fired auxiliary boiler is to()Acool the furnace to prevent pre-ignitionBremove explosive vapors from the furnaceCevaporate accumulated unburned fuel oilDprovide sufficient air in the furnace to allow ignition of the fuel
单选题The fuel supply system to an automatic auxiliary boiler, will be automatically shutdown if the boiler ()Asalinity is abnormally highBsteam demand is too highCwater level is abnormally lowDfeedwater flow is low
单选题The fuel oil supply system to an automatic auxiliary boiler, will automatically shutdown if the boiler ()Asteam demand is highBsalinity is highCsafety valve simmersDburner flame is extinguished
单选题A firebox explosion in an automatically fired auxiliary boiler may be the result of ()Aexcessive purging before lighting offBinsufficient trail for ignition periodCa faulty transformer in the ignition circuitDinsufficient purging before lighting off
单选题The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ().AwaterBvoltageCfuel pressureDsteam pressure
单选题When there is a flame failure in an automatically fired auxiliary boiler, the ().Aair supply is shut offBfuel supply is shut offCwater supply is shut offDsafety valve lifts
单选题Exhaust pipes for separate diesel engines can be combined only when ()Aspace limitations prevent separately run pipesBthe engines are small auxiliary unitsCthey are arranged to prevent gas backflow to each engineDa waste heat boiler is installed
单选题A () boiler is an auxiliary boiler sometimes included in a steamships installation for supplying steam to auxiliaries in port.AmonkeyBdonkeyCwaste heatDmain
单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()Aair or water in the furnaceBcombustion pulsesCfuel oil pump failureDflame failure
单选题Ignition failure in an automatically controlled auxiliary boiler could be caused by()Acarbon deposits on the flame scannerBhigh fuel oil temperatureClow fuel oil viscosityDhigh steam pressure
单选题Burner ignition failure in an automatically fired auxiliary boiler would be caused by()Aa burned out solenoid in the oil supply valveBhigh temperature excess airCincorrectly setting the hot-well dump valveDan incorrectly positioned burner snubber realy
单选题The amount of chloride content in the water of an auxiliary boiler can be reduced by()Aadding hydrazineBblowing down the boilerCadding phenolphthaleinDadding a sulfite chloride scavenger
单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure
单选题Excessive alkalinity of the water in an auxiliary boiler can cause ().Acaustic embrittlement of the boiler metalBacidic corrosion of the boiler metalChard scale deposits on the boiler tubesDetching of the heat exchange surfaces
单选题Flame failure in an automatically fired auxiliary boiler can from a/an ()Aincorrect electrode settingBincorrect nozzle positionCclogged fuel nozzleDbroken high tension lead
单选题Prior to lighting off a cold automatically fired auxiliary boiler, you should ().Acheck and regulate the water levelBclose the air cock once fires are litCblowdown the gage glassDcrack the steam stop to assure protective steam flow
单选题As for a oil-fired boiler too much air would indicated by ().Ayellowish flameBgolden yellow flameCmilky flameDbrilliant white flame