单选题Short cycling of a refrigeration compressor refers to ().Afrequently grounding outBfrequently starting and stoppingCrunning too fastDrunning too slow

单选题
Short cycling of a refrigeration compressor refers to ().
A

frequently grounding out

B

frequently starting and stopping

C

running too fast

D

running too slow


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow

Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system

If a refrigeration system were short of refrigerant, the condition would result inA.continuous running of the compressorB.high suction pressureC.high discharge pressureD.short cycling of the compressor on the water failure switch

If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling

单选题Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().Aoverheated compressor bearingsBexcess lube oil viscosityCcarbon deposits on the compressor piston ringsDwax crystals forming in the lubricant

单选题Short cycling of a refrigeration compressor refers to ().Afrequently grounding outBfrequently starting and stoppingCrunning too fastDrunning too slow

单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow

单选题If a refrigeration compressor were short cycling on the low pressure cutout switch, the probable cause for this might be the ().Asystem was overcharged with refrigerantBhigh pressure switch was improperly adjustedCexpansion valve strainers were fouledDsuction valves were leaking slightly

单选题If a refrigeration compressor is running continuously without lowering the temperature in the refrigerated space, the trouble may be ().Aa shortage of compressor oilBwarm food in the refrigeratorCexcessive condenser cooling waterDa shortage of refrigerant

单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().Arun continuouslyBnot startChave high discharge pressureDshort cycle on the high pressure switch

单选题()are supplied by main switchboard directly.ASuez Canal searchlight, air compressor and air conditioning compressorBAir compressor, boiler blower and refrigeration plantCBoiler blower, Suez Canal searchlight and refrigeration plantDSuez canal searchlight, air compressor and boiler blower

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().Aalways be wide open when the compressor restartsBcontinue to operate as if the system were in operationCremain open until evaporator pressure equalizes, then close until the compressor restartsDalways be completely closed until the compressor restarts

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题If the capacity of the refrigeration compressor is too large, the saturation temperature will ().AriseBfallCbe maintained constantDNone of the above

单选题The compressor in an air-cooled condensing refrigeration system is short cycling on the high pressure cutout switch()Asystem is overcharged with refrigerantBsystem is low on refrigerantCdischarge valves are leaking excessivelyDdischarge valves are leaking slightly

单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().Acompressor damage from improper lubricationBrefrigerant absorption by the lubricantCincreased viscosity in the lubricantDcarbon deposit on the compressor suction valves

单选题In the refrigeration compressor the temperature of the vapor is () by compression.AraisedBrisenCreducedDmaintained constant

单选题It should be ensured that only () vapor is handled by the refrigeration compressor.AhumidityBdryCsteamDoil

单选题The purpose of the refrigeration system low pressure cutout switch is to ()Aprotect the compressor from liquid flood backBprotect the compressor from low discharge pressureCstart and stop the compressor upon system demandDstart the compressor after a drop in the evaporator pressure

单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor

单选题Sweating of the refrigeration system compressor crankcase is caused by ().Atoo much superheatBinsufficient superheatCsuction pressure too lowDexcessive refrigerant returning to the compressor