单选题A constant output voltage from an AC generator is maintained by the ().Aprime mover governorBexciter generatorCvoltage regulatorDreverse power relay

单选题
A constant output voltage from an AC generator is maintained by the ().
A

prime mover governor

B

exciter generator

C

voltage regulator

D

reverse power relay


参考解析

解析: 暂无解析

相关考题:

( ) can provide an asynchronous link between two ac electric power system with different nominal frequencies. A.The HVDC (high voltage DC) transmissionB.The EHV (extra-high voltage) AC transmissionC.The AC distributionD.Generators

The generator voltages are usually stepped up to the transmission voltage level by ( ). A.series capacitorB.parallel reactorsC.step-up transformersD.step-down transformers

Overspeed of the diesel engine driving an electric generator could cause ______.A.low voltage tripB.reverse power tripC.damage to windingsD.excessive exhaust temperatures

The output voltage of a 440 volt, 60 hertz, AC generator is controlled by theA.prime mover speedB.exciter output voltageC.load on the alternatorD.number of poles

Equal power factors on paralleled AC generators are maintained by an automatic ________.A.governor control switchB.reverse power relayC.reverse current relayD.voltage regulator

单选题The output voltage of a three-phase alternator is regulated by the ().AAC voltage to the armatureBAC voltage to the fieldCDC voltage to the armatureDDC voltage to the field

单选题The main purpose of an electric space heater installed in a large AC generator is to ()Aprevent the windings from becoming brittleBprevent moisture from condensing in the windings during shutdownCprevent acidic pitting of the slip ringsDkeep the lube oil warm for quick starting

单选题In a vapor compression refrigeration the evaporating pressure is maintained constant by the action of the (), which removes vapor from the evaporator at the same rate at which it is formed.AevaporatorBcompressorCcondenserDnone of the above

单选题Voltage generated by most AC generators is fed from the machine to the bus by means of().Abrushes on a commutatorBbrushes on slip ringsCslip rings on a commutatorDdirect connections from the stator

单选题A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an ()ArotorBstatorCexciterDarmature

单选题The voltage output of an AC generator is controlled by()Avarying the DC exciter voltageBvarying the reluctance of the air gapCregulating the speed of the prime moverDshorting out part of the armature windings

单选题The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ().AdroopBdropCdipDregulation

单选题If the resistance of a circuit is cut in half and the applied voltage is kept constant, the current flow will be ().AdoubledBquadrupledCunchangedDcut in half

单选题The power factor of an AC generator operating singularly is determined by the ()Aconnected loadBprime mover speedCfield excitationDgenerators rated voltage

单选题The power factor at which a paralleled AC generator operates is usually adjusted by the ().Aconnected loadBprime mover speedCfield excitationDgenerators rated voltage

单选题When securing an AC generator, you should FIRST ().Aopen the generator circuit breakerBswitch the voltage regulator to “manual”Cdecrease the field excitation to minimumDreduce the load on the unit

单选题Self-excited a-cgenerator with "error operated" voltage control systems draw the full excitation power for the machine terminalsThis dispenses with the current transformers, reactors and capacitors necessary for accurate compounding, but renders the excitation system vulnerable to variations in its output voltageWhich of the following is correct about the generator mentioned according to the sentences above ().AIt consumes no excitation powerBIt has current transformersCComponents are needed for accurate compoundingDIts excitation system is vulnerable to voltage variations

单选题Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the ()Amanual positionBbus neutral positionCraise voltage positionDtransfer position

单选题The alternating current generator supplying a load has a voltage drop resulted from the loadWhen the load has a lagging power factor this voltage drop ().Ais smallBmay be neglectedCis usefulDis considerable

单选题The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the ().Aprime mover speedBexciter output voltageCload on the alternatorDnumber of poles

单选题The initial voltage of self-excitation generator set up by()Aresidual magnetismBvoltage regulatorCelectrical current for excitationDthe other running generator

单选题Which of the following should be the FIRST step in removing a generator from parallel operation?()ATrip the generator off the switchboardBTurn off all electrical equipmentCRemove the load from the off going generatorDIncrease the cycles of the generator staying on the line

单选题The overspeeding of the diesel engine driving an electric generator could cause ().Alow voltage trip to tripBreverse power trip to tripCdamage to windingsDexcessive exhaust temperatures

单选题Overspeed of the diesel engine driving an electric generator could cause().Alow voltage tripBreverse power tripCdamage to windingsDexcessive exhaust temperatures

单选题When the voltage remains constant and the resistance is increased in a series circuit, the flow of current ()Aincreases by the square of the original valueBincreasesCremains the sameDdecreases

单选题When paralleling two AC generators, the frequency of the machine coming on-line, immediately prior to closing its breaker, should be ()Aslightly less than the oncoming generator frequencyBthe same as the bus frequencyCslightly greater than the bus frequencyDthe same as the bus voltage

单选题The voltage developed by an AC generator is controlled by varying the ()Aspeed of the prime moverBAC excitation to the fieldCDC excitation to the fieldDDC excitation of the voltage regulator