单选题The indications of a scavenge fire are excessive black smoke, () and peeling from scavenge trunking.Aturbo-chargers surgeBspark seen from the drainsCpaint blisteringDall above are right
单选题
The indications of a scavenge fire are excessive black smoke, () and peeling from scavenge trunking.
A
turbo-chargers surge
B
spark seen from the drains
C
paint blistering
D
all above are right
参考解析
解析:
暂无解析
相关考题:
The fire _______ a lot of smoke but little damage was done.A. gave awayB. sent offC. sent upD. gave off
If the scavenge fire is of a more major nature, if there is a risk of the fire extending or if the scavenge trunk is adjacent to the crankcase with risk of a hot spot developing it sometimes becomes necessary to_______the engineA.stopB.startC.speed upD.slow down
Engine operating conditions may be indicated by the color of the exhaust smoke Black smoke could indicate .A.an insufficient speed droop settingB.an overloaded engineC.clogged drain holes in the oil control ringsD.complete combustion
What would white exhaust smoke from a diesel engine probably mean ________.A.Late fuel injectionB.Excess combustion airC.Dribbling injector tipsD.Excessive lube oil consumption
Which of the following is a slip of tongue A.No cross, no crown.B.No pains, no gains.C.No sweat without sweet.D.No smoke without fire.
单选题If a scavenge fire starts, the engine must be put to “()” and the fuel must be taken off the cylinders affected by the fire.Astop engineBfinished with engineCdead slow aheadDdead slow astern
单选题The indications of a scavenge fire are excessive black smoke, () and peeling from scavenge trunking.Aturbo-chargers surgeBspark seen from the drainsCpaint blisteringDall above are right
单选题Once a scavenge fire is detected the engine ().Awill be speeded upBshould be slowed downCmust slow downDhave to be slow down
单选题Black smoke coming from a boiler can be caused by ().Alow water levelBhigh water levelCexcessively high fuel pressureDlow oil temperature
单选题Which of the following would cause a diesel to have black smoke?()Aleaky injectorBwater in the gasCtoo heavy oilDwater in the oil
单选题The straight stream capability of an all-purpose nozzle is used in fighting a class A fire to().Ashield fire fighters from radiant heatBbreak up burning materialCget the most water possible on the fireDdrive heat and smoke ahead of the fire fighters
单选题Engine operating conditions may be indicated by the color of the exhaust smoke.Black smoke could indicate()Aan insufficient speed droop settingBan overloaded engineCclogged drain holes in the oil control ringsDcomplete combustion
单选题A high-velocity fog stream can be used in fire fighting situations to drive heat and smoke ahead of the fire fighters in a passageway. This technique should only be used when().Ausing a 2-1/2 inch hoseBthere is an outlet for the smoke and heatCthe fire is totally contained by the ship's structureDat least two fog streams can be used
单选题You notice smoke coming from an open laundry room doorway.After activating the fire alarm,which of the following would you do FIRST().AAttempt to determine what is burningBAcquire the nearest self contained breathing apparatusCBreak out the nearest fire hoseDWait for the fire team to arrive and assist as directed
单选题A distorted furnace in a fire-tube auxiliary boiler may be the result of ()Afiring for extended periods in the low fire modeBoverheating, due to waterside depositsCvarying the water level above the crown sheetDcarrying excessive alkalinity in the boiler water
单选题Automatic fire dampers in ventilation systems are operated by use of().Aremotely operated valvesBfusible linksCC02 system pressure switchesDheat or smoke detectors
单选题Automatic fire dampers in ventilation systems are operated by a().Aremote operated valveBfusible linkCCO2 system pressure switchDheat or smoke detector
单选题A smoke _____ system provides families with early warning of fire.AcollectionBrepressionCdetectionDresonance
单选题Why will a turbocharger diesel engine produce black smoke if excessive additional load is applied too quickly?()AExhaust energy would draw excess airBThe inertia of the turbocharger rotor causes a time lag which delays the turbocharger speed increaseCExhaust gas pumping losses are increased due to turbine windageDExhaust gas back pressure falls slightly due to increased nozzle action
单选题Indications of ()are loss in power and irregular running of the engine, high exhaust temperatures of corresponding unite, high local temperature in scavenge trunk, surging of turbocharger, and sparks and smoke emitted from scavenge drains.Aa crankcase explosionBa scavenge fireCabnormal compression ratio
单选题It is necessary to secure the forced ventilation to a compartment where there is a fire to().Aallow the exhaust fans to remove smokeBextinguish the fire by carbon monoxide smotheringCprevent additional oxygen from reaching the fireDprotect fire fighting personnel from smoke
单选题If the scavenge fire is of a more major nature, if there is a risk of the fire extending or if the scavenge trunk is adjacent to the crankcase with risk of a hot spot developing it sometimes becomes necessary to ()the engine.AstopBstartCspeed upDslow down
单选题Late fuel injection occurring at, or after TDC in a diesel engine is indicated by excessive exhaust smoke and ()Alow exhaust temperatureBlow firing pressureCfuel knock in each cylinderDmechanical knock in each cylinder
单选题Once a scavenge fire is detected, fuel should be shut off from the affected cylinders and cylinder lubrication increased () the risk of seizure.Ato protectBto guardCto maximizeDto minimize
单选题Black smoke coming from a boiler can be caused by ().Alow water levelBlow oil pressureCexcessively high fuel pressureDan improper air/fuel ratio
单选题The basic training in fire prevention and fire fighting should include the practical elements which should allow the trainees to acquire the ability to ().Ause self-contained breathing apparatusBuse various types of portable fire extinguishersCeffect a rescue in a smoke-filled space wearing breathing apparatusDAll of the above
单选题A four-stroke cycle, turbocharged, 1000 horsepower diesel engine has been operating under loadThe load suddenly increases, causing excessive black exhaust smoke, and a rapid rise in the lube oil temperatureIn response to this condition, you should:()Areduce loadBcheck your exhaustCadjust cooling water temperatureDincrease lube oil flow
单选题When occurring a fire in the scavenge air box, the following measures should be taken except for()Areducing speed to SLOW and asking bridge for permission to stopBstopping the fuel oil supplyCswitching-on the auxiliary blowersDputting the scavenge air box fire extinguishing equipment into function