单选题Adequate attention must be given to the water cooling system of the air compressors, for () can cause condensation on the cylinder walls.AovercoolingBpoor coolingCoverloadingDunloading

单选题
Adequate attention must be given to the water cooling system of the air compressors, for () can cause condensation on the cylinder walls.
A

overcooling

B

poor cooling

C

overloading

D

unloading


参考解析

解析: 暂无解析

相关考题:

What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above

If the coolant temperature of a closed cooling water system for a diesel enginegradually increases, the trouble usually is( ).A.a broken shaft on the freshwater pumpB.an excessive accumulation of scale in the heat exchangerC.an incorrect thermostatic element operating rangeD.lube oil in the cooling water

_____ allows for expansion and water make up in the water cooling system.A.A top tankB.A head tankC.A head valveD.A drain tank

High diesel engine cooling water temperatures can be caused by ______.A.air in the cooling systemB.an overhauled water pumpC.correct amount of coolantD.no air in the cooling system

Why is it necessary to have routine testing of the cooling water?A.To ensure that the proper residuals of treatment chemicals, as specified, are maintained all timeB.To trace leakage in the cooling water systemC.It is not necessaryD.To detect the presence of contaminants in the water that may be injurious to the cooling system

单选题In a closed cooling water system, which of the problems can cause the water pressure to fluctuate?()AAn open vent in the cooling systemBA fouled sea chestCA restricted water passage in the engineDAir entrained in the cooling water

单选题The device allowing for the change in volume of the cooling water in a propulsion diesel engine closed cooling system is the ().Afresh water expansion tankBsea water expansion tankCthermostatic expansion valveDjacket water cooler accumulator

单选题After "F.W.E" is given, the air system is shut down, the () gear put in, all drains and indicator cocks opened, and the cooling water kept running.AsteeringBtimingCturningDrunning

单选题If the jacket water temperature in an auxiliary diesel engine cooling system is lower than normal, the probable cause is ()Aair binding of the engine cooling systemBa cracked water cooled exhaust manifoldCblockage in the heat exchangerDfaulty operation of the thermostat

单选题Where is the cooling water from the compensating tank in the cooling water system of main engine lead to?()Adischarge side of the centrifugal pumpBsuction side of the centrifugal pumpCthe lowest point of the cooling water systemDinlet of the main engine

单选题() allows for expansion and water make up in the water cooling system.AA top tankBA head tankCA head valveDA drain tank

单选题High diesel engine cooling water temperatures can be caused by ().Aair in the cooling systemBan overhauled water pumpCcorrect amount of coolantDno air in the cooling system

单选题In a closed cooling system for a turbocharged, four-stroke/cycle diesel engine, fluctuating water pressure can be caused by ()Aimproper venting of the cooling systemBcarrying the expansion tank water level too highCa totally clogged impeller in the cooling water pumpDan incorrectly set cooling system temperature control

单选题The expansion tank for a diesel engine closed cooling system is designed to maintain a constant head on the system and ().Areduce water temperatureBreduce water turbulenceCprovide an air cushionDallow for an increase in water volume as the engine warms up

单选题After the order “()” is given, the air system is shut down, the turning gear put in, all drains and indicator cocks opened, and the cooling water and lubricating oil systems kept running.AStand-by EngineBStop EngineCFinished With EngineDDead Slow Ahead

单选题The highest pressure in any closed diesel engine freshwater cooling system is at the ().Ajacket water outletBexpansion tank inletCheat exchanger inletDcooling water pump outlet

单选题As to the piston cooling, of the following, which statement is not true?()ABecause the piston is exposed to very high temperature, it must be cooledBThe lower the piston cooling temperature is, the better it isCBoth water and lube oil can be used as coolantDOne of the piston cooling methods is vibration cooling, with better effect

单选题Which of the following statements is correct concerning diesel engine cooling water systems?()AEach engine must have its own engine driven cooling water pump capable of providing cooling for all ranges of operationBpropulsion engines with bores exceeding 200 mm are to be fitted with a means to display the cooling water temperature of each cylinderCAt least two independent sea suctions are to be provided for supplying water to the engine jackets or to the heat exchangersDSuitable strain are to be fitted between the circulating pumps and heat exchangers when sea water is used for direct cooling

单选题In a diesel engine jacket water cooler, with seawater cooling the fresh water, the()Asea water temperature must never be warmer than 40℃Bjacket water pressure should always be greater than the sea water pressureCjacket water temperature must always be less than 60℃Djacket water pressure must always be less than the sea water pressure

单选题If the water level dropped rapidly in the expansion tank of a closed diesel engine cooling water system, you should suspect a ().Aloss of suction in the circulating pumpBleak in the primary cooling systemCbroken raw water pump shaftDburned or cracked piston in one cylinder

单选题Which of the following problems can cause fluctuating pressures in the closed cooling system of a main propulsion diesel engine?()ADefective temperature controls in the systemBCavitation in the cooling water pumpCOpened vent in the cooling systemDRestricted water passages in the engine

单选题Temperature control valves installed in the jacket cooling water system of a diesel engine modulates the rate of water flow through the ().Acooling water pumpBnozzle cooling passagesCcylinder jacketsDheat exchanger

单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system

单选题Which of the following statements is correct for the design and installation of diesel engine cooling water systems?()AAn alarm device with audible and visible signals is required for all cooling water systemsBPropulsion engines with bores over 200 mm are to be fitted with cooling water jacketsCEach totally enclosed cooling system shall be provided with a suitable head tankDDrain cocks are to be provided at the lowest points of all cylinder water jackets

单选题In a diesel engine cooling water system, a pH of 60 indicates a/an ().Aslightly acidic conditionBslightly alkaline conditionCovertreatment of waterDneutral condition of water

单选题In the process of the stand-by, warm-up the engine usually through give preheat of which parts of the diesel engine?()Acooling water of the cooling systemBfuel of the FO systemCLO of the LO systemDcooling water of the cooling system and LO of the LO system

单选题If the compressor-discharge temperature is higher than the receiver temperature()Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some of the refrigerant from the system