单选题A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()AShared Ethernet runs on POWER4 systemsBVirtual Ethernet runs on POWER4 systemsCShared Ethernet requires a Virtual I/O server and Advanced Power VirtualizationDVirtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization

单选题
A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()
A

Shared Ethernet runs on POWER4 systems

B

Virtual Ethernet runs on POWER4 systems

C

Shared Ethernet requires a Virtual I/O server and Advanced Power Virtualization

D

Virtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization


参考解析

解析: 暂无解析

相关考题:

You are trying to connect directly into the LAN prot of a Ezonexam router. You want to telnet to the local Cisco router using TCP/IP but cannot create a session.What should you do to resolve the problem?A. Use a straight-through cable to connect your computer's COM port to the router's console port.B. Use a crossover cable to connect your computer's COM port to the router's console port.C. Use a straight-through cable to connect your computer's COM port to the router's Ethernet port.D. Use a crossover cable to connect your computer's Ethernet port to the router's Ethernet port.E. Use a rollover cable to connect your computer's Ethernet port to the router's Ethernet port.F. Use a straight-through cable to connect your computer's Ethernet port to the router's Ethernet port.G. None of the above

whether to go with a shared or switched fast LAN technology once you start to max out your shared Ethernet of token-ring LAN is tough call. Users and analysts involved in(101)high-speed LANs have learned the benefits of each. However, there are trade-offs to each, and(102)which fast LAN technology to choose is critical for(103)network performance problems and(104)costly purchasing mistakes.A.avoidingB.clippingC.choosingD.decidingE.dissolving

A customer has an existing rack environment with 18 x365 and 2 x255 servers.  How can the customer monitor and manage the hardware even if the systems are shut down?()A、Use PC Anywhere over the Ethernet LAN.B、Use RDM and Aurema to manage the systems.C、Connect high-speed modems to each of the systems’ serial ports to use IBM Director.D、Interconnect the Remote Supervisor Adapters II (RSA II) in the x365 servers to the x255 servers.

Your customer has converted from traditional servers to BladeCenter technology and has a requirement for an RSA adapter on a new BladeCenter server.  Which of the following options would you use? ()A、Remote Supervisor Adapter II (RSA II Slimline)B、Management Module, which comes standard on the BladeCenterC、Acoustic Attenuation ModuleD、Ethernet NICs

A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()A、Etherchannel and trunkingB、Network Interface Backup and EtherchannelC、Shared Ethernet Adapter (SEA) Failover and EtherchannelD、Network Interface Backup and Shared Ethernet Adapter failover

A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A、1B、7C、15D、31

Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers.  Which of the following commands will identify the Shared Ethernet Adapter mapping?()A、ifconfig -aB、netstat -nrC、lsmap -all -netD、lsdev -Cc adapter

A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()A、Two dual-port PCIe adaptersB、A four-port PCIe Ethernet adapterC、Four separate PCIe Ethernet adaptersD、Two embedded Integrated Virtual Ethernet adapters (IVE)

When creating a virtual Ethernet adapter on the HMC for a VIO server, what is the advantage of checking the box to access external network (trunk)?()A、Allows the creation of a shared Ethernet adapterB、Allows the use of VLANsC、Allows the consolidation of multiple networks on one adapterD、Allows EtherChannel load balancing

A customer is debating whether to use Shared Ethernet versus Virtual Ethernet.  Which of the following best describes a key difference between Shared and Virtual Ethernet?()A、Shared Ethernet runs on POWER4 systemsB、Virtual Ethernet runs on POWER4 systemsC、Shared Ethernet requires a Virtual I/O server and Advanced Power VirtualizationD、Virtual Ethernet requires a Virtual I/O server and Advanced Power Virtualization

Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()A、Configure a Shared Ethernet Adapter on the Virtual I/O Server.B、Use the same virtual LAN ID on each LPAR.C、Set up IP routing through an LPAR on each system.D、Set up an IP firewall through an LPAR on each system.

Which functionality would a customer use to share available CPU resources between AIX and Linux partitions on a Power system?()A、 Dynamic LPARB、 Micro PartitionsC、 Entitled capacityD、 Multiple Shared Processor Pools

Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A、VIO ServerB、AIX 5.2 ML4C、Shared Ethernet AdapterD、AIX 5.3 with Advanced Power Virtualization

A customer has Windows servers and applications that use block I/O. The customer cannot affordthe cost of a fibre channel infrastructure but still requires shared storage. Which configurationmeets these requirements at the lowest cost?()A、iSCSI HBAs and N3400B、MicrosoftiSCSI initiator and N3400C、MicrosoftiSCSI initiator and DS3400D、SAN04B-R multi-protocol router and DS3400

Company.com is adding HACMP to an existing pair of nodes. One node is using EtherChannel  with only one adapter. The other node is using regular Ethernet connection to the switch. The customer is going to increase the number of network interfaces to two for each node.  What other considerations need to be addressed in a HACMP environment?()  A、 Al interfaces used for HACMP heartbeats must be identical. Differences in the interfaces will cause heartbeat failure.B、 The network interfaces should all be configured with the same frame type. The use of regular Ethernet frames is mandatory.C、 Network interfaces for HACMP must be all the same,Ethernet or 802.3. It does not matter which,as long as they are all the same.D、 HACMP can use any network interface supported by AIX. The options on the various interfaces are masked by the Ethernet switch and do not affect HACMP.

Companycom purchased a p5 570 with no plans to partition. The customer plans to use the ASMI interface to power on and off the machine. How can ASMI be accessed without a HMC?()A、By typing diags and then going to the ASMI menusB、Through SSH from a TCP/IP connection on the serverC、Through WebSM which is connected to a system Ethernet portD、By connecting through a web browser to an HMC Ethernet port

The customer currently has 20 servers with 1 TB of internal capacity on each server. The serverscommunicate over 10/100/1000 Ethernet. The customer would like to move to a shared storagesubsystem with Fibre Channel hard drives. Budget is a key issue for them. Which option wouldallow for the lowest cost to implement?()A、IBM DS8700 B、IBM N6040 C、IBM Storwize V7000 D、IBM XIV Storage System

Companycom tells the technical sales specialist that recent announcements state that virtual lan in the datacenter is the best option. The customer wants to use interpartition communication to save on adapters and increase performance. The systems are going to have shared and dedicated processor partitions. Some of the partitions will be running AIX 5.2 and some will be running AIX 5.3. The second p5 590 will be running a mixture of AIX 5.3 and Linux partitions with 2.6 kernel. What limitations of vlan/interpartition  communication should be discussed with this customer?()A、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet is supported on AIX 5L and Linux 2.5 and above. B、Virtual Ethernet can be used within groups of shared OR groups of dedicated processor partitions, but not both simultaneously. Virtual Ethernet comes with AIX 5L, and is supported in AIX 5.2 or AIX 5.3 partitions, but not Linux. C、Virtual Ethernet can be used in both shared and dedicated processor partitions. Virtual Ethernet can run in an AIX 5.3 or Linux 2.6 Kernel, but not AIX 5.2 partitions. Virtual Ethernet can only connect partitions within a single system. D、Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet can connect partitions between systems if the HMC is shared between systems.

Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()A、VLAN tagsB、EtherChannelC、Virtual EthernetD、Shared Ethernet Adapter

You are designing an n-tier Java EE application. You have already decided that some of your JSPs willneed to get data from a Customer entity bean. You are trying to decide whether to use a Customer stubobject or a Transfer Object. Which two statements are true?()A、The stub will increase network traffic.B、The Transfer Object will decrease data staleness.C、The stub will increase the logic necessary in the JSPs.D、In both cases, the JSPs can use EL expressions to get data.E、Only the Transfer Object will need to use a Business Delegate.

单选题A customer has a requirement to eliminate single points of failure for an application.  They have allocated one Ethernet adapter to each VIO server on the system. Which features of PowerVM and AIX will support the customer requirement?()AEtherchannel and trunkingBNetwork Interface Backup and EtherchannelCShared Ethernet Adapter (SEA) Failover and EtherchannelDNetwork Interface Backup and Shared Ethernet Adapter failover

单选题Which functionality would a customer use to share available CPU resources between AIX and Linux partitions on a Power system?()A Dynamic LPARB Micro PartitionsC Entitled capacityD Multiple Shared Processor Pools

单选题A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A1B7C15D31

多选题You are designing an n-tier Java EE application. You have already decided that some of your JSPs willneed to get data from a Customer entity bean. You are trying to decide whether to use a Customer stubobject or a Transfer Object. Which two statements are true?()AThe stub will increase network traffic.BThe Transfer Object will decrease data staleness.CThe stub will increase the logic necessary in the JSPs.DIn both cases, the JSPs can use EL expressions to get data.EOnly the Transfer Object will need to use a Business Delegate.

单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()AShared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.BVirtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.CShared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.DVirtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

单选题Companycom purchased a p5 570 with no plans to partition. The customer plans to use the ASMI interface to power on and off the machine. How can ASMI be accessed without a HMC?()ABy typing diags and then going to the ASMI menusBThrough SSH from a TCP/IP connection on the serverCThrough WebSM which is connected to a system Ethernet portDBy connecting through a web browser to an HMC Ethernet port