单选题A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration? ()ARestore the configuration from NVRAM using the Switch Module Web interface BBack up the configuration of the Ethernet module in bay 1 and restore it to the Ethernet module in bay 2 using the AMM CSwap the modules, which will automatically resynch the settings stored in the Advanced Management Module DBack up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface

单选题
A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration? ()
A

Restore the configuration from NVRAM using the Switch Module Web interface 

B

Back up the configuration of the Ethernet module in bay 1 and restore it to the Ethernet module in bay 2 using the AMM 

C

Swap the modules, which will automatically resynch the settings stored in the Advanced Management Module 

D

Back up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface


参考解析

解析: 暂无解析

相关考题:

A network administrator has installed an N7K-F248-25XP module into an existing chassis. The module is powered on, but the interfaces are all in VDC0. What is the reason for this?()   A、 The chassis needs an EPLD upgrade to support the new module type.B、 The default VDC cannot support F2 modules.C、 The interfaces must be allocated into a VDC for F2 modules only.D、 The module has failed GOLD diagnostics, and the switch has isolated the ports to protect the integrity of the system.

A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration? ()A、Restore the configuration from NVRAM using the Switch Module Web interface B、Back up the configuration of the Ethernet module in bay 1 and restore it to the Ethernet module in bay 2 using the AMM C、Swap the modules, which will automatically resynch the settings stored in the Advanced Management Module D、Back up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface

A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A、4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server B、Cisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module C、Fibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module D、Cisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

When configuring unified ports on a 5548 switch, which port ordering must be respected?()A、 Fibre Channel ports must be configured from the first port in the module.B、 Ethernet ports must be configured from the last port in the module.C、 Fibre Channel ports must be configured from the last port in the module.D、 Ethernet ports must be configured from the first port in the module.

A customer has purchased a triple channel memory kit containing three DDR3 RAM modules. Theserver the RAM is intended for only has a dual channel capable motherboard. Which of the following is the BEST action to perform?()A、Install only two modules as the RAM has to be installed in pairsB、Purchase one additional RAM module to make it even. Three modules will function as triplechannel and the additional module will be for parityC、Purchase dual channel memory. The triple channel memory may be incompatible with theserver motherboardD、Install the RAM.Two modules will perform as dual channel and one as single channel

A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request?()A、Brocade Enterprise 20-port 8Gb SAN switch module B、Brocade 20-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter share C、Brocade Enterprise 10-port 8Gb SAN switch module D、Brocade 10-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

A retail customer installs a BladeCenter into an existing 10/100 Ethernet network. Due to cost considerations, the customer uses Copper Pass-thru Modules. After installing this solution, the customer finds that they have no network connectivity. Which of the following at is causing the problem?()A、Copper Pass-thru Modules only support 1000Mb line speeds. B、Spanning Tree has been enabled on the Copper Pass-thru Module. C、The customer does not have the latest firmware loaded on the Copper Pass-thru Module. D、The customer is using LS21 Blades

A banking customer has the following requirements for an IBM BladeCenter solution with high speed fibre channel: (1)four 4-socket Microsoft SQL servers with two hot swap SAS drives  (2)two physical Microsoft Active Directory Servers  (3)twenty-two physical Citrix servers  (4)three physical Web servers (5)one physical vCenter server   (6)eight vSphere hosts  Which configuration minimally satisfies these requirements?()A、Three IBMBladeCenter S chassis, three Brocade Fibre modules, six Ethernet modulesB、Three IBMBladeCenter E chassis, three Brocade Fibre modules, six Ethernet modulesC、Four IBMBladeCenter H chassis, four QLogic Fibre Channel modules, eight Ethernet modulesD、Three IBMBladeCenter H chassis, three QLogic Fibre Channel modules, six Ethernet modules

A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()A、You can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.B、Using blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.C、The Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.D、The blade servers do not work with the Optical Pass-Thru Module.

A customer has two Ethernet Switch Modules installed in an IBM BladeCenter Enterprise chassis. The modules were configured identically. The Ethernet module in bay one was inadvertenly reset to factory defaults. Which solution returns the module to the customer-specific configuration?()A、Back up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface B、Swap the modules, which will automatically resynch the settings stored in the Advanced Management Module C、Back up the configuration of the Ethernet module in bay one and restore it to the Ethernet module in bay two using the AMM D、Restore the configuration from NVRAM using the Switch Module Web interface

A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()A、Fiber Channel Switch ModuleB、Gb Ethernet expansion cardC、Myrinet Cluster expansion cardD、Ethernet Switch Module

The primary line module has failed and the spare line module is nowactive.What occurs,by default,when the primary line module returns to an operational status?()A、The primary line module is inactive for five minutes and then becomes active.B、The primary line module is in standby mode,while the spare line module remains active.C、The primary line module becomes active immediately and the spare line module becomes inactive.D、The primary and spare line modules are active for five minutes,after which time the spare line module becomes inactive.

A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request of the following?()A、Brocade Enterprise 20-port 8Gb SAN switch moduleB、Brocade 20-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenterC、Brocade Enterprise 10-port 8Gb SAN switch moduleD、Brocade 10-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

单选题A network administrator has installed an N7K-F248-25XP module into an existing chassis. The module is powered on, but the interfaces are all in VDC0. What is the reason for this?()A The chassis needs an EPLD upgrade to support the new module type.B The default VDC cannot support F2 modules.C The interfaces must be allocated into a VDC for F2 modules only.D The module has failed GOLD diagnostics, and the switch has isolated the ports to protect the integrity of the system.

单选题A customer has two Ethernet Switch Modules installed in an IBM BladeCenter Enterprise chassis. The modules were configured identically. The Ethernet module in bay one was inadvertenly reset to factory defaults. Which solution returns the module to the customer-specific configuration?()ABack up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface BSwap the modules, which will automatically resynch the settings stored in the Advanced Management Module CBack up the configuration of the Ethernet module in bay one and restore it to the Ethernet module in bay two using the AMM DRestore the configuration from NVRAM using the Switch Module Web interface

单选题A banking customer has two Ethernet Switch Modules installed in an IBM BCE chassis. The modules were configured identically. The Ethernet module in bay 1 was accidentally reset to factory defaults. Which solution returns the module to the customer-specific configuration? ()ARestore the configuration from NVRAM using the Switch Module Web interface BBack up the configuration of the Ethernet module in bay 1 and restore it to the Ethernet module in bay 2 using the AMM CSwap the modules, which will automatically resynch the settings stored in the Advanced Management Module DBack up the configuration from Ethernet module in bay 2 and restore it to the module in Bay 1 using the switch CLI or Web interface

单选题A customer has purchased a triple channel memory kit containing three DDR3 RAM modules. Theserver the RAM is intended for only has a dual channel capable motherboard. Which of the following is the BEST action to perform?()AInstall only two modules as the RAM has to be installed in pairsBPurchase one additional RAM module to make it even. Three modules will function as triplechannel and the additional module will be for parityCPurchase dual channel memory. The triple channel memory may be incompatible with theserver motherboardDInstall the RAM.Two modules will perform as dual channel and one as single channel

单选题A media customer has an IBM BladeCenter E with ten HS22 Blade server installed. Currently only one Ethernet port is available for each server. What is required to enable the second port on eachserver?()AFiber Channel Switch ModuleBGb Ethernet expansion cardCMyrinet Cluster expansion cardDEthernet Switch Module

单选题A banking customer has the following requirements for an IBM BladeCenter solution with high speed fibre channel: (1)four 4-socket Microsoft SQL servers with two hot swap SAS drives  (2)two physical Microsoft Active Directory Servers  (3)twenty-two physical Citrix servers  (4)three physical Web servers (5)one physical vCenter server   (6)eight vSphere hosts  Which configuration minimally satisfies these requirements?()AThree IBMBladeCenter S chassis, three Brocade Fibre modules, six Ethernet modulesBThree IBMBladeCenter E chassis, three Brocade Fibre modules, six Ethernet modulesCFour IBMBladeCenter H chassis, four QLogic Fibre Channel modules, eight Ethernet modulesDThree IBMBladeCenter H chassis, three QLogic Fibre Channel modules, six Ethernet modules

单选题A customer is considering BladeCenter H and S chassis. Which of the following is a reason to implement BladeCenter H?()ASupport for10Gb internal networkBSupport for SSDCSupport for integrated disk drivesDSupport for8Gb FC Switch Modules

单选题A customer wants to boot from SAN with their IBM BladeCenter infrastructure.  What is required for the customer to be able to perform this? ()A4GB Modular Flash Drive for each Blade Server and Dual 15.8GB 2.5 Solid State Drive for each Blade Server BCisco Intelligent Gb Ethernet Switch Module and IBM BladeCenter Copper Pass-thru Module CFibre Channel Expansion Card for each Blade Server and Fibre Channel SAN Switch Module DCisco Intelligent Gb Ethernet Switch Module and Dual 15.8GB 2.5 Solid State Drive for each Blade Server

单选题A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request?()ABrocade Enterprise 20-port 8Gb SAN switch module BBrocade 20-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter share CBrocade Enterprise 10-port 8Gb SAN switch module DBrocade 10-port 8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

单选题A banking customer deployed an IBM BladeCenter chassis with one Brocade 8Gb SAN switch module. The customer requires an 8Gb uplink or higher. Which configuration will meet this request of the following?()ABrocade Enterprise 20-port 8Gb SAN switch moduleBBrocade 20-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenterCBrocade Enterprise 10-port 8Gb SAN switch moduleDBrocade 10-port8Gb SAN switch module and Brocade Advanced Performance Monitoring for IBM BladeCenter

单选题The primary line module has failed and the spare line module is nowactive.What occurs,by default,when the primary line module returns to an operational status?()AThe primary line module is inactive for five minutes and then becomes active.BThe primary line module is in standby mode,while the spare line module remains active.CThe primary line module becomes active immediately and the spare line module becomes inactive.DThe primary and spare line modules are active for five minutes,after which time the spare line module becomes inactive.

单选题A retail customer installs a BladeCenter into an existing 10/100 Ethernet network. Due to cost considerations, the customer uses Copper Pass-thru Modules. After installing this solution, the customer finds that they have no network connectivity. Which of the following at is causing the problem?()ACopper Pass-thru Modules only support 1000Mb line speeds. BSpanning Tree has been enabled on the Copper Pass-thru Module. CThe customer does not have the latest firmware loaded on the Copper Pass-thru Module. DThe customer is using LS21 Blades

单选题A manufacturing customer has an IBM BladeCenter H chassis with four, HX5 with MAX5 4-socket blades installed. Each blade has the optional Fibre Channel Expansion card. The customer wants redundancy and is going to install the following configuration:  (1)two Brocade 20-Port SAN Switch Modules  (2)two Nortel Networks 1/10 GB Uplink ESM  (3)a redundant AMM  What is the minimum number of power supplies needed for this configuration to have full redundancy?()A4B3C2D8

单选题Which statement describes queue and buffer managment in the E-series router?()ABuffer memory is managed dynamically in the I/O module.BBuffer memory is managed dynamically in the switch fabric.CBuffer memory is managed dynamically on egress line modules.DBuffer memory is managed dynamically on ingress line modules

单选题A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the internal fibre switches. Consequently. the customer wants to use the Optical Pass-Thru Module (OPM).  What TRUE statement should be mentioned to the customer regarding the OPM?()AYou can not put the Optical Pass-Thru Module in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch.BUsing blade servers with the Optical Pass-Thru Module will require more fibre ports on the external fibre switch.CThe Optical Pass-Thru Module does not provide the customer with an opportunity to reuse their fibre switch.DThe blade servers do not work with the Optical Pass-Thru Module.