An inert gas system is designed to reduce the possibility of tank explosions by ______.A.eliminating sparks and fire in the vicinity of cargo tanksB.removing all hydrocarbon gases from the cargo tanksC.blanketing cargo tanks with inert foamD.reducing the oxygen concentration below levels necessary for combustion

An inert gas system is designed to reduce the possibility of tank explosions by ______.

A.eliminating sparks and fire in the vicinity of cargo tanks

B.removing all hydrocarbon gases from the cargo tanks

C.blanketing cargo tanks with inert foam

D.reducing the oxygen concentration below levels necessary for combustion


相关考题:

An inert gas system installed on a tanker is designed to ______.A.aid in the stripping and cleaning of cargo tanksB.increase the rate of discharge of cargoC.force toxic and explosive fumes from a cargo tank to vent to the outside atmosphereD.lower the oxygen levels inside cargo tanks,making explosion nearly impossible

An inert gas system on a tanker should be used to ______.A.prevent the generation of flammable or combustible gas in tanksB.blow out cargo lines to prevent the build up of gas concentrationsC.dilute tank atmospheres to keep gas concentrations below the lower explosive limitD.prevent fires in the pumproom by continually displacing flammable vapors

How does an inert gas system on a tanker function to prevent explosions in cargo tanks?A.De-energizes the "charged mist" effectB.Maintains a positive pressure on the vent header to cool the flammable vaporsC.Inert gas filters out the flammable vapors from the cargo tank spacesD.Inert gas dilutes the flammable vapor and air concentrations to keep them below the lower explosive limit

A cargo tank that is initially gas freed,can be inerted by introducing inert gas by a process known as ______.A.dilutionB.displacementC.precipitationD.Either A or B

You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take?A.Cut in another IG fan to increase gas flowB.Open the pressure control valve until the pressure increasesC.Open the tank isolation valve to the fully open positionD.Reduce the pumping rate

Which of the listed functions is the purpose of a gas scrubber in an inert gas generation system ________.A.Cools the inert gasB.Maintains the oxygen content at 5% by volumeC.Drains off static electricity in the inert gasD.Maintains the water seal on the gas main

______ shall be provided in every cargo tank and slop tank in accordance with the appropriate Resolutions.A.A load on top systemB.Direct line systemC.Circle line systemD.An inert gas system

Inerting means ______.A.The introduction of inert gas into a tank with the object of reducing the oxygen content to below 8% by volumeB.The introduction of inert gas into a gas free tank for the purpose of reducing the oxygen content to below 8% by volumeC.The introduction of inert gas into a cargo tank during cargo discharge to replace the volume of discharged cargoD.All of the above

What is NOT a requirement for the safe and effective use of a crude oil washing system ________.A.Strip all tanks and remove the bottom residueB.Use an inert gas system while washing tanksC.Use portable washing machines to reach areas obscured by structural members in the tanksD.Debottom the tank used as the source for the tank cleaning machines

When a non-volatile cargo is carried in a tank that has not been previously gas freed,then that tank shall ______.A.be purged with hydrocarbon gas prior to loadingB.be gas-freed after loading operationsC.not be maintained in an inert conditionD.be maintained in an inert condition

Which statement about inert gas pressures in a cargo tank is TRUE ________.A.The pressures of the inert gas in the tank may create excessive pressure at the pump while dischargingB.Gas pressures should be maintained at the highest permissible level throughout the discharging processC.High gas pressures may cause pyrophoric oxidation in the tankD.High gas pressures may cause loss of suction when stripping

You are planning to use a crude oil washing system.What precaution must be taken with the tank as the source for the washing machines ________.A.It must be debottomed and the level lowered by at least one meterB.The oil in the source tank must be sampled for compatibilityC.The source tank must have been crude oil washed at least once in the past 150 daysD.The inert gas system must lower the oxygen content to a maximum of 12% oxygen in the tank

You are planning to use the crude oil washing system on your tanker.What is required to prevent electrostatic buildup in the tanks ________.A.The portable machines should be set at the proper drop for the first wash before the fixed machines are usedB.The tank used as the source for the tank cleaning machines should be debottomed for at least one meterC.The inert gas system must reduce the oxygen content in the tank to at least 18%D.The fixed machines must be operated simultaneously with the portable machines to equalize the electrostatic potential

单选题How does an inert gas system on a tanker function to prevent explosions in cargo tanks? ()ADe-energizes the charged mist effectBMaintains a positive pressure on the vent header to cool the flammable vaporsCInert gas filters out the flammable vapors from the cargo tank spacesDInert gas dilutes the flammable vapor and air concentrations to keep them below the lower explosive limit

单选题An inert gas system is designed to reduce the possibility of tank explosions by().Aeliminating sparks and fire in the vicinity of cargo tanksBremoving all hydrocarbon gases from the cargo tanksCblanketing cargo tanks with inert foamDreducing the oxygen concentration below levels necessary for combustion

单选题A cargo tank that is initially gas freed,can be inerted by introducing inert gas by a process known as().AdilutionBdisplacementCprecipitationDEither A or B

单选题What action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?()AThe tank must be gas freedBThe tank must be ballastedCThe tank must be vented to the atmosphereDThe bypass valve must also be closed

单选题You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take? ()ACut in another IG fan to increase gas flowBOpen the pressure control valve until the pressure increasesCOpen the tank isolation valve to the fully open positionDReduce the pumping rate

单选题An inert gas system installed on a tanker is designed to().Aaid in the stripping and cleaning of cargo tanksBincrease the rate of discharge of cargoCforce toxic and explosive fumes from a cargo tank to vent to the outside atmosphereDlower the oxygen levels inside cargo tanks,making explosion nearly impossible

单选题Inerting means().Athe introduction of inert gas into a tank with the object of reducing the oxygen content to below 8% by volumeBthe introduction of inert gas into a gas free tank for the purpose of reducing the oxygen content to below 8% by volumeCthe introduction of inert gas into a cargo tank during cargo discharge to replace the volume of discharged cargoDAll of the above

单选题The purpose of the deck seal in an inert gas system is to prevent().Aflammable vapors from entering machinery spaceBflue gas escaping to atmosphereCinert gas escaping to atmosphereDair entering inert gas system

单选题The combined fan discharge rate in an inert gas system is related to the().Ashoreside loading rateBmaximum cargo pump discharge rateCboiler forced draft fan rateDsize of the largest cargo tank

单选题An inert gas system on a tanker should be used to().Aprevent the generation of flammable or combustible gas in tanksBblow out cargo lines to prevent the build up of gas concentrationsCdilute tank atmospheres to keep gas concentrations below the lower explosive limitDprevent fires in the pumproom by continually displacing flammable vapors

单选题The component in an inert gas system used for cleaning the gas of solid and sulphur combustion products,while simultaneously cooling the inert gas,is called the().AfilterBcoolerCscrubberDpurifier

单选题An inert gas system on a tanker should be used to().Aprevent the generation of flammable or combustible gas in tanksBblow out cargo lines to prevent gas concentrationsCdilute tank atmospheres to keep gas concentrations below the lower explosive limitDprevent fires in the pumproom by continually displacing flammable vapors

单选题Each inert gas system must be designed to supply the cargo tanks with a gas,or mixture of gasses,that has an oxygen content by volume of().A5% or lessB10% or lessC15% or lessD20% or less

单选题()shall be provided in every cargo tank and slop tank in accordance with the appropriate Resolutions.AA load on top systemBDirect line systemCCircle line systemDAn inert gas system