单选题Each inert gas system must be designed to supply the cargo tanks with a gas,or mixture of gasses,that has an oxygen content by volume of().A5% or lessB10% or lessC15% or lessD20% or less
单选题
Each inert gas system must be designed to supply the cargo tanks with a gas,or mixture of gasses,that has an oxygen content by volume of().
A
5% or less
B
10% or less
C
15% or less
D
20% or less
参考解析
解析:
暂无解析
相关考题:
An inert gas system installed on a tanker is designed to ______.A.aid in the stripping and cleaning of cargo tanksB.increase the rate of discharge of cargoC.force toxic and explosive fumes from a cargo tank to vent to the outside atmosphereD.lower the oxygen levels inside cargo tanks,making explosion nearly impossible
How does an inert gas system on a tanker function to prevent explosions in cargo tanks?A.De-energizes the "charged mist" effectB.Maintains a positive pressure on the vent header to cool the flammable vaporsC.Inert gas filters out the flammable vapors from the cargo tank spacesD.Inert gas dilutes the flammable vapor and air concentrations to keep them below the lower explosive limit
Which method is used to supply inert gas from a flue gas system to the cargo tanks?A.Exhaust gas pressure from the stackB.High capacity fanC.Inert gas compressorD.Natural aspiration
Inerting means ______.A.The introduction of inert gas into a tank with the object of reducing the oxygen content to below 8% by volumeB.The introduction of inert gas into a gas free tank for the purpose of reducing the oxygen content to below 8% by volumeC.The introduction of inert gas into a cargo tank during cargo discharge to replace the volume of discharged cargoD.All of the above
The blowers of an inert gas generation system aboard a tanker,will be automatically secured if ______.A.Normal water supply at the water seal is lostB.The temperature of the inert gas being delivered to the cargo tanks is more than 150℉C.The cooling water supply to the scrubbers is lostD.All of the above
The deck water seal of the inert gas system ______.A.Cools the inert gas and prevents soot from entering the cargo tanksB.Acts as an emergency shutdown when inlet pressures exceed the safe working pressureC.Prevents the backflow of hydrocarbon gasses into nonhazardous areasD.Relieves sudden large overpressures in the system
The venting system shall be provided with devices to prevent the passage of ______ into the cargo tanks.A.flameB.inert gasC.airD.oil gas
An inert gas system is designed to reduce the possibility of tank explosions by ______.A.eliminating sparks and fire in the vicinity of cargo tanksB.removing all hydrocarbon gases from the cargo tanksC.blanketing cargo tanks with inert foamD.reducing the oxygen concentration below levels necessary for combustion
Each ship having an inert gas system must have a portable instruments to measure concentrations of hydrocarbon vapor in inert atmospheres and also to measure ______.A.nitrogenB.oxygenC.carbon dioxideD.water vapor
单选题Each inert gas system gas main must have an automatic shut down valve at the outlet of the gas production plant. This valve must close automatically upon().Acargo pump failureBblower failureCdeck seal low water levelDlow inert gas temperature
单选题During loading and discharging operations,in addition to when the cargo tanks have been properly filled,each inert gas system must be capable of maintaining a minimum gas pressure of().A150 millimeters of water pressureB125 millimeters of water pressureC100 millimeters of water pressureD75 millimeters of water pressure
单选题The deck water seal of the inert gas system().Acools the inert gas and prevents soot from entering the cargo tanksBacts as an emergency system shutdown when the inlet pressures exceed the safe working pressure in the hazardous zoneCprevents the backflow of hydrocarbon gasses into nonhazardous areasDrelieves sudden large overpressures in the system
单选题An inert gas system is designed to reduce the possibility of tank explosions by().Aeliminating sparks and fire in the vicinity of cargo tanksBremoving all hydrocarbon gases from the cargo tanksCblanketing cargo tanks with inert foamDreducing the oxygen concentration below levels necessary for combustion
单选题What action must be taken when an individual cargo tank is closed off from the inert gas system by the tank isolation valve?()AThe tank must be gas freedBThe tank must be ballastedCThe tank must be vented to the atmosphereDThe bypass valve must also be closed
单选题Your tanker is designed to carry anhydrous ammonia in bulk.The keel was laid in 1980.Which statement concerning the carriage of this cargo is TRUE().AA flammable gas detection system must be installed in each cargo pump roomBTanks may not be located on deckCCarriage of this cargo is authorized by issuance of an IMO CertificateDAluminum and copper alloys are prohibited from being in valve parts in contact with the cargo
单选题An inert gas system installed on a tanker is designed to().Aaid in the stripping and cleaning of cargo tanksBincrease the rate of discharge of cargoCforce toxic and explosive fumes from a cargo tank to vent to the outside atmosphereDlower the oxygen levels inside cargo tanks,making explosion nearly impossible
单选题Inerting means().Athe introduction of inert gas into a tank with the object of reducing the oxygen content to below 8% by volumeBthe introduction of inert gas into a gas free tank for the purpose of reducing the oxygen content to below 8% by volumeCthe introduction of inert gas into a cargo tank during cargo discharge to replace the volume of discharged cargoDAll of the above
单选题Which method is used to supply inert gas from a flue gas system to the cargo tanks?()AExhaust gas pressure from the stackBHigh capacity fanCInert gas compressorDNatural aspiration
单选题Hoses used for cargo transfer operations must be tested and inspected at specified intervals by().Aa representative of the Captain of the PortBthe operator of the vessel or facilityCa representative of the National Cargo BureauDlow inert gas temperature
单选题The purpose of the deck seal in an inert gas system is to prevent().Aflammable vapors from entering machinery spaceBflue gas escaping to atmosphereCinert gas escaping to atmosphereDair entering inert gas system
单选题Each ship having an inert gas system must have a portable instruments to measure concentrations of hydrocarbon vapor in inert atmospheres and also to measure().AnitrogenBoxygenCcarbon dioxideDwater vapor
单选题The combined fan discharge rate in an inert gas system is related to the().Ashoreside loading rateBmaximum cargo pump discharge rateCboiler forced draft fan rateDsize of the largest cargo tank
单选题An inert gas system on a tanker should be used to().Aprevent the generation of flammable or combustible gas in tanksBblow out cargo lines to prevent the build up of gas concentrationsCdilute tank atmospheres to keep gas concentrations below the lower explosive limitDprevent fires in the pumproom by continually displacing flammable vapors
单选题An inert gas system on a tanker should be used to().Aprevent the generation of flammable or combustible gas in tanksBblow out cargo lines to prevent gas concentrationsCdilute tank atmospheres to keep gas concentrations below the lower explosive limitDprevent fires in the pumproom by continually displacing flammable vapors
单选题The blowers of an inert gas generation system aboard a tanker,will be automatically secured if().Anormal water supply at the water seal is lostBthe temperature of the inert gas being delivered to the cargo tanks is more than 150°FCthe cooling water supply to the scrubbers is lostDall of the above
单选题()shall be provided in every cargo tank and slop tank in accordance with the appropriate Resolutions.AA load on top systemBDirect line systemCCircle line systemDAn inert gas system
单选题The deck water seal of the inert gas system().Acools the inert gas and prevents soot from entering the cargo tanksBacts as an emergency shutdown when inlet pressures exceed the safe working pressureCprevents the backflow of hydrocarbon gasses into nonhazardous areasDrelieves sudden large overpressures in the system