单选题The bypass valve on a self-contained breathing device should be opened if().Ayou are entering a space containing poisonous vaporsByou are entering a space containing explosive gasesCthe regulator of the breathing apparatus malfunctionsDthe face piece of the breathing device is too tight

单选题
The bypass valve on a self-contained breathing device should be opened if().
A

you are entering a space containing poisonous vapors

B

you are entering a space containing explosive gases

C

the regulator of the breathing apparatus malfunctions

D

the face piece of the breathing device is too tight


参考解析

解析: 暂无解析

相关考题:

On a ship, the locker or space containing the self-contained breathing apparatus must _____.A.be located in close proximity to the main control stationB.be equipped with battery powered emergency lightingC.be marked SELF-CONTAINED BREATHING APPARATUSD.All of the above

Self-contained breathing apparatus is used to ______.A.make underwater repairs to bargesB.determine if the air in a tank is safe for menC.enter areas that may contain dangerous fumes or lack oxygenD.resuscitate an unconscious person

The CO2 flooding system is actuated by a sequence of steps which are ______.A.break glass, pull valve, break glass, pull cylinder controlB.sound evacuation alarm, pull handleC.open bypass valve, break glass, pull handleD.open stop valve, open control valve, trip alarm

What is the minimum period of time that the air supply for a self-contained breathing apparatus is required to last?________.A.10 minutesB.20 minutesC.30 minutesD.90 minutes

If the head pressure of a reciprocating refrigeration compressor is excessiveA.the relief valve should open before the high pressure cutoutB.the relief valve should open and allow the excess refrigerant to flow to the receiverC.the high pressure cutout switch should operate before the relief valve opensD.you should close the discharging valve

What is one way to escape hardware bypass mode?() A. Reset the cabling.B. Power cycle the device.C. Bounce the service tunnels.D. Unlock the device from the console.

The bypass valve on a self-contained breathing device should be opened if ______.A.You are entering a space containing poisonous vaporsB.You are entering a space containing explosive gasesC.The regulator of the breathing apparatus malfunctionsD.The face piece of the breathing device is too tight

The function of the bypass valve on the self-contained breathing apparatus is to ______.A.control the pressure of the oxygen as it enters the bodyB.allow the wearer to manually give himself oxygenC.release excess heat which would otherwise cause the bottle to explodeD.allow exhaled gases to pass outside the bottle

Gas masks ______.A.should be worn while fighting a fireB.can be used in atmospheres deficient in oxygenC.filter contaminants from air that is to be breathedD.may be substituted for a self-contained breathing apparatus

单选题When operating the air supply system in a covered lifeboat the().Afuel supply valve should be closedBhatches,doors,and oar ports should be closedCair cylinder shut-off valve should be closedDengine should be shut off

单选题Gas masks().Ashould be worn while fighting a fireBcan be used in atmospheres deficient in oxygenCfilter contaminants from air that is to be breathedDmay be substituted for a self-contained breathing apparatus

单选题A self-contained breathing apparatus is used to().Amake underwater repairs to bargesBdetermine if the air in a tank is safe for menCenter areas that may contain dangerous fumes or lack oxygenDresuscitate an unconscious person

单选题If a hydraulic governor has been refilled with oil, the engine should be operated until it reaches normal temperaturethen the air should be purged, and the()Arack position should be adjustedBcompensating needle valve should be opened fully compensatingCneedle valve should be adjusted to stabilize operationDspeed limiting device should be adjusted

单选题The C02 flooding system is actuated by a sequence of steps which are().Abreak glass,pull valve,break glass,pull cylinder controlBsound evacuation alarm,pull handleCopen bypass valve,break glass,pull handleDopen stop valve,open control valve,trip alarm

单选题The rated operating time of a self-contained breathing device may be reduced in actual use because of().Apressure differences in the atmosphereBthe length of the hose attached to the facepieceCthe physical exertion of the person wearing the deviceDspaces containing poisonous vapors

单选题Worn diesel engine intake valve guides can result in ()Aincreased engine breathing efficiencyBexcessive valve lashCexcessive lube oil consumptionDlower than normal fuel consumption

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题If the head pressure is too high,()Athe relief valve should open before the high-pressure cutoutBthe relief valve should open and let excess refrigerant go to receiverCthe high-pressure cutout switch should operate before the relief valve opensDclose in on the suction valve

单选题The function of the bypass valve on the self-contained breathing apparatus is to().Acontrol the pressure of the oxygen as it enters the bodyBallow the wearer to manually give himself oxygenCrelease excess heat which would otherwise cause the bottle to explodeDallow exhaled gases to pass outside the bottle

单选题What is one way to escape hardware bypass mode?()AReset the cabling.BPower cycle the device.CBounce the service tunnels.DUnlock the device from the console.

单选题The self-contained breathing device should not be used in which situation?()AOxygen deficient spacesBCompartments containing poisonous vaporsCFighting fires that produce heavy smokeDUnderwater search

单选题Which emergency equipment should you keep near the towing bitts().AA self-contained breathing apparatusBA boat hook and a spanner wrenchCA fire ax and/or cutting torchDA Stokes litter basket

单选题Which emergency equipment should you keep near the towing bitts? ()AA self-contained breathing apparatus (SCBA)BA boat hook and a spanner wrenchCA fire ax and/or cutting torchDA Stokes litter basket

单选题You are about to enter a compartment to investigate a suspected smoldering fireIf youre not wearing a self-contained breathing apparatus, you should test the compartments atmosphere to determine if there is/are ().Asufficient oxygen to sustain human lifeBan explosive mixture in the compartmentCa toxic atmosphere in the compartmentDAll of the above

单选题The basic training in fire prevention and fire fighting should include the practical elements which should allow the trainees to acquire the ability to ().Ause self-contained breathing apparatusBuse various types of portable fire extinguishersCeffect a rescue in a smoke-filled space wearing breathing apparatusDAll of the above

单选题Why should you wear a self-contained breathing apparatus before entering the engine room after the fixed CO2 system has been discharged to combat a major fire?()ABecause carbon dioxide dilutes the oxygen concentration in the atmosphere and may cause asphyxiationBBecause carbon dioxide breaks down in a fire into carbon monoxide which may cause blood poisoning in the person breathing this gasCBecause carbon dioxide is a colorless and odorless gas that becomes highly toxic in the presence of high temperatures and will quickly incapacitate a person exposed to this gasDThis action is unnecessary as carbon dioxide is not poisonous nor toxic but is a relatively harmless gas

单选题A ship must have a self-contained breathing apparatus to be used as protection from gas leaking from a refrigeration unit. To meet this requirement,you may use().Aa gas mask certified by the Mine Safety and Health AdministrationBthe same self-contained breathing apparatus required with the fireman's outfitCan oxygen breathing apparatus,provided that the device has been inspected within three yearsDa portable ventilation system that will provide a complete change of air every three minutes