An AIX server is configured with a static IP address but the system administrator wants the server to give out IP addresses for clients who want to use the dynamic host configuration protocol instead of static IP addresses.How is this accomplished?()A、Use SMIT to have the server use DHCP instead of a static addressB、Edit /etc/rc.tcpip and start the dhcpsd daemonC、Use the network options command to enable ipforwardingD、Edit /etc/rc.net to set network options back to default
An AIX server is configured with a static IP address but the system administrator wants the server to give out IP addresses for clients who want to use the dynamic host configuration protocol instead of static IP addresses.How is this accomplished?()
- A、Use SMIT to have the server use DHCP instead of a static address
- B、Edit /etc/rc.tcpip and start the dhcpsd daemon
- C、Use the network options command to enable ipforwarding
- D、Edit /etc/rc.net to set network options back to default
相关考题:
AIX shows the boot order in the following output.hdisk0 hdisk1 blv=hd5 cd0.What will happen when the system administrator reboots the server?() A.The server will boot from cd0B.The server will boot from hdisk0C.The server will boot into SMS modeD.The server will boot from hdisk1
Which of the following support dynamic LPAR?()A、AIX v5.1B、AIX v4.3.3C、SuSe Linux Enterprise Server 9 (SLES9)D、SuSe Linux Enterprise Server 8 (SLES8)
Multiple users are trying to telnet to the AIX server. They are able to ping the server successfully, but are getting the following error message: telnet: connect: A remote host refused an attempted connect operation Which of the following could be the cause of this problem?()A、The routing table on the AIX server is incorrect.B、The IP address on the network adapter is incorrect.C、The portmap daemon is not running on the AIX server.D、The inetd daemon is not running on the AIX server.
Companycom is migrating from p670 systems running AIX 5.2 to p5 595 systems running AIX 5.3. They will be changing out only the system units. They will re-use the existing 61D drawers and adapters with the new p5 595 systems. What compatibility issue must be considered?() A、APV features are not supported for some legacy POWER4 adaptersB、APV will require the most current maintenance level for AIX 5.2C、APV features will require that legacy POWER4 adapters be updated with new microcodeD、The Virtual IO Server must run AIX 5.3 and the LPARs can run either AIX 5.2 or AIX 5.3
A customer has budget sign-off to purchase a new p5-550 2-way server to replace their aging 2-way 7025-6F0. They like the advantages of the Simultaneous Multi Processing (SMT) ability of this server. Their application is certified at AIX 5.2 and is scheduled for AIX 5.3 certification in six months. The Chief Information Officer is concerned that they will lose the budget if they do not purchase the server this fiscal year. What is the most relevant and cost-effective advice the pSeries technical specialist can offer?()A、Purchase a 4-way p630 to compensate for not using SMT.B、Purchase the p5-550 server and install AIX 5.2, which can be upgraded to AIX 5.3 later.C、Purchase the p5-550 server and install AIX 5.2 and enable SMT.D、Suspend the purchase of a new machine at this time and upgrade the current server to a 4-way server.
AIX shows the boot order in the following output.hdisk0 hdisk1 blv=hd5 cd0. What will happen when the system administrator reboots the server?()A、The server will boot from cd0B、The server will boot from hdisk0C、The server will boot into SMS modeD、The server will boot from hdisk1
An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()A、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#B、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameC、On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameD、On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBM iC、LinuxD、VIO Server
Which of the following is the lowest cost DB2 product that can be legally installed on an AIX server?()A、DB2 Express EditionB、DB2 Personal EditionC、DB2 Workgroup Server EditionD、DB2 Enterprise Server Edition
A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications. The pSeries technical specialist should recommend purchasing which of the following?()A、p5 hardware, AIX 5.2, Virtual I/O ServerB、POWER4 hardware, AIX 5.3, Virtual I/O Server,C、p5 hardware, AIX 5.3, Advanced POWER Virtualization featureD、POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature
AIX shows the boot order in the following output: hdisk0 hdisk1 blv=hd5 cd0 What will happen when the system administrator reboots the server?()A、The server will boot from cd0B、The server will boot from hdisk0C、The server will boot into SMS modeD、The server will boot from hdisk1
Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBMiC、LinuxD、VIO Server
A data center includes a Power 750 server running AIX and Linux, and PS700 Blades running AIX. What can the customer use to update AIX and Linux, create and deploy LPARs, and set energy caps for both servers from a single console?()A、PowerVM Standard EditionB、VMControl Standard EditionC、Hardware Management ConsoleD、IBM Systems Director Standard Edition
Companycom is planning on upgrading from a pSeries S85 running AIX 4.3.3 to a p5 570 with an HMC. The new server will run AIX 5L 5.2. What should be performed prior to the migration?()A、Verify the ISV application runs on AIX 5.2B、Power4 to POWER5 upgrades are not supported without a application recompileC、Check the placement and size of the boot logical volume and disk space requirements on the S85D、AIX 4.3.3 to AIX 5L 5.2 migrations are perfectly compatible so nothing needs to be checked
Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A、VIO ServerB、AIX 5.2 ML4C、Shared Ethernet AdapterD、AIX 5.3 with Advanced Power Virtualization
Users complain an AIX server is running slow. Which of the following commands can be run to determine what is consuming systems resources?()A、 tprofB、 lpstatC、 ps auxD、 entstat
Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A、Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B、Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C、Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D、Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.
A system administrator will use a mksysb from a uniprocessor microchannel server running AIX 5.1 to install a multiprocessor chrp server. What else is required?()A、A 5.1 AIX base media setB、A 5.1 Additional Device Driver CDC、A mksysb of the multiprocessor chrp serverD、A savevg of the uniprocessor microchannel server
Multiple users are trying to telnet to the AIX server. They are able to ping the server successfully, but are getting the following error message: telnet: connect: A remote host refused an attempted connect operation Which of the following options could be the cause of this problem()A、The routing table on the AIX server is incorrect.B、The IP address in the /etc/hosts file is incorrect,C、The portmap daemon is not running on the AIX server.D、The inetd daemon is not running on the AIX server.
单选题A system administrator will use a mksysb from a uniprocessor microchannel server running AIX 5.1 to install a multiprocessor chrp server. What else is required?()AA 5.1 AIX base media setBA 5.1 Additional Device Driver CDCA mksysb of the multiprocessor chrp serverDA savevg of the uniprocessor microchannel server
单选题A system administrator has a mksysb on tape of an AIX 5.2 machine and needs to install it on a different server. How can this be accomplished?()AInstall the base AIX from 5.2 media and then install the mksysb overtop.BMount the tape and use the tar command to install AIX and the rest of the contents of the rootvg.CInsert the mksysb tape and a 5.2 base media CD and then boot to maintenance mode and initiate the install.DInstall AIX 5.2 from base media and then perform an update_all install from the mksysb tape of the original machine.
单选题A technical specialist has installed a Host Bus Adapter (HBA) on a p5-550 server. The system has four AIX 5L V5.3 partitions and a Virtual I/O server. The HBA will be used to connect all four partitions to a DS8000 storage array. What else must be performed to make the storage available to the partitions?()AAllocate the HBA to a client partition.BRestart the Virtual I/O Server to detect the changes.CInstall the device driver for the DS8000 in each of the four AIX partitions.DAllocate the HBA to the VIO server partition and install necessary drivers.
单选题A system administrator will be migrating a server from AIX 5.1 to AIX 5.2 and is uncertain if the application running on the server will function properly after the migration. What is the fastest way to return to the previous AIX level if the application does not work?()AUse base media to restore system to AIX 5.1.BUse an alt_disk_install and boot back to the AIX 5.1 rootvg.CMake a mksysb of the original AIX to restore back to the AIX 5.1 level.DPerform the AIX 5.2 upgrade using update_all with the commit option and reject filesets to return to AIX 5.1.
单选题An administrator has received an update CD with the latest technology level for AIX 5.3. The current operating system level of the server is at base AIX 5.3. What action needs to be taken to apply the new technology level to the server?()ARun smit update_allBRun smit install_allCBoot from the installation mediaDRun the update_all command from the mounted CD
单选题An AIX LPAR has been reconfigured to use direct-attached disks. What is the best way to fully remove and delete the Virtual IO volumes?()AOn the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#BOn the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameCOn the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_nameDOn the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
单选题Multiple users are trying to telnet to the AIX server. They are able to ping the server successfully, but are getting the following error message: telnet: connect: A remote host refused an attempted connect operation Which of the following options could be the cause of this problem()AThe routing table on the AIX server is incorrect.BThe IP address in the /etc/hosts file is incorrect,CThe portmap daemon is not running on the AIX server.DThe inetd daemon is not running on the AIX server.
单选题AIX shows the boot order in the following output: hdisk0 hdisk1 blv=hd5 cd0 What will happen when the system administrator reboots the server?()AThe server will boot from cd0BThe server will boot from hdisk0.CThe server will boot into SMS modeDThe server will boot from hdisk1.