The system administrator has created a mksysb to attempt to clone to another system. Which of the following considerations is NOT true?()A、When using a mksysb to clone a system that has had device driver updates applied, the target system does not need to be updated with device driver Updates to match the source systems level, as the mksysb will have the needed drivers.B、CHRP architecture systems cloned form non-CHRP architecture systems with Updates applied may fail to boot due to incompatibilities between the updated kernel in the mksysb image and the base level devices.chrp.base.rte fileset installed during the cloning process.C、If the source and target system kernels are different (for example, rs6k and rspc), one MUST boot from CD-ROM installation media, at the same operating system level as the mksysb being restored.D、The RECOVER_DEVCIES option allows the choice to recover the customized ODM attributes from the mksysb(for example, network addressing, static routes, tty settings, and multi-port adapter cards). The target devices must be in The same location as the source machine, or the install will fail and the device wil not be defined.

The system administrator has created a mksysb to attempt to clone to another system. Which of the following considerations is NOT true?()

  • A、When using a mksysb to clone a system that has had device driver updates applied, the target system does not need to be updated with device driver Updates to match the source systems level, as the mksysb will have the needed drivers.
  • B、CHRP architecture systems cloned form non-CHRP architecture systems with Updates applied may fail to boot due to incompatibilities between the updated kernel in the mksysb image and the base level devices.chrp.base.rte fileset installed during the cloning process.
  • C、If the source and target system kernels are different (for example, rs6k and rspc), one MUST boot from CD-ROM installation media, at the same operating system level as the mksysb being restored.
  • D、The RECOVER_DEVCIES option allows the choice to recover the customized ODM attributes from the mksysb(for example, network addressing, static routes, tty settings, and multi-port adapter cards). The target devices must be in The same location as the source machine, or the install will fail and the device wil not be defined.

相关考题:

A system administrator has just applied an update to an AIX system to correct a problem, The APAR number is IX49035 and was shipped as part of the PTF number U437542. After applying the APAR fix, the administrator wants to ensure that the fix is applied before informing the system users of the corrected problem. Which of the following commands should the system administrator run to verify that the APAR fix has been applied to the system?()A.lslpp -f IX49035B.lslpp -fB U437542C.instfix -f IX49035D.instfix -ik IX49035

A system was rebooted and is taking a long time toreturn. The administrator has logged into the HMC and sees reference code 0c9.What does this mean?() A.The system is configuring a device.B.A system initiated dump has started.C.The system is varyingon a volume group.D.The system is running an inbuilt self test.

A system administrator has placed an AIX base media CD-ROM in a server and initiated a reboot. The server has an ascii terminal attached to it. Which key or key combination must the administrator press to initiate the maintenance mode?()A、5B、MC、F8D、Ctrl-Alt-Delete

A system administrator has edited the necessary files for setup of an AIX system to serve as a bootp server.  Which of the following commands is required to complete the activation?()A、telinit -qB、startsrc -s bootpdC、refresh -s inetd

An administrator has added a new device to a system and wants to determine if it has been correctly added to the ODM database. Which command would the system administrator use?()A、odmgetB、odmaddC、odmshowD、odmcreate

An administrator is planning an upgrade of a major software package on an application server.The software has been tested successfully in a test environment and it is ready to go into production. Which of the following steps should the administrator take next?()A、Identify necessary operating system updatesB、Implement the changeC、Document the changeD、Schedule system down time

A system administrator has been asked to install an APAR but wants to be able to easily remove it. Which install option should be used?()A、applyB、cleanupC、commitD、reject

An AIX system administrator has setup disk quotas.  Where can the reports be found on the system?()A、/var/adm/acct/sum B、/var/adm/ras C、/usr/sbin/acct D、/var/adm/wtmp

An administrator has a requirement to mirror the operating system on a VIO server. Which of the following IOS commands will achieve this?()A、 mirrorvgB、 iosmirrorC、 mirroriosD、 mkiosmirror

A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A、/usr/bin/errmsg "System upgraded to AIX 5.2"B、/usr/bin/errlog "System upgraded to AIX 5.2"C、/usr/bin/errupdate "System upgraded to AIX 5.2"D、/usr/bin/errlogger "System upgraded to AIX 5.2"

An administrator is notified that a resource group has failed over from the home node, Node1 to a standbynode, Node2 and that Node1 has been powered off. Upon restarting Node1 the administrator checks the AIXerror log and the cluster.log Which of the following is the most likely cause of the failure of Node1?()A、The operating system crashedB、A disk failure forced a volume group off lineC、The System Resource Controller executed a system haltD、The topology services daemon has crashed due to an ODM mismatch

A system administrator has a filesystem called /test/data in volume group datavg. Which of the following commands will allow the administrator to create a mirrored copy of the filesystem’s data?()A、chfsB、chlvC、mklvcopyD、mkfscopy

A system administrator has been asked to lock a specific login account. Which of the following commands is used to accomplish this?()A、pwdckB、usrckC、chuserD、rmuser

A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()A、viB、mkitabC、telinitD、startsrc

A system administrator is monitoring a system that has recently shown a decrease in performance. The administrator suspects there is an overload of traffic on a single Ethernet adapter. Which of the following commands is best to identify a possible overload of the Ethernet adapter?()A、pingB、iostatC、netstatD、ifconfig

A system administrator has been asked to document the hardware configuration of a system. Which command can be used to assist in this task?()A、lscfgB、mkdevC、lslppD、cfgmgr

A system was rebooted and is taking a long time toreturn. The administrator has logged into the HMC and sees reference code 0c9. What does this mean?()A、The system is configuring a device.B、A system initiated dump has started.C、The system is varyingon a volume group.D、The system is running an inbuilt self test.

A system administrator is monitoring a system that has recently shown a decrease in performance.The administrator suspects that the system may be low on memory and may be paging excessively.Which of the following commands is best to identify a possible paging problem?()A、iostatB、netstatC、psD、vmstat

The System Administrator has set up shared processors on three partitions in the p5 590 system. The shared processors have been set to uncapped. The system administrator notices that the logical partition is acting like it is capped. What is the most probable cause?()A、The uncapped weight has been set to 0.B、The uncapped weight has been set to 128.C、The processing unit for that partition was set to .1 processing units. A full processor was assigned.D、The processing unit for that partition was set to 0.50 processing units. A full processor was assigned.

A system administrator has just applied an update to an AIX system to correct a problem, The APAR number is IX49035 and was shipped as part of the PTF number U437542. After applying the APAR fix, the administrator wants to ensure that the fix is applied before informing the system users of the corrected problem. Which of the following commands should the system administrator run to verify that the APAR fix has been applied to the system?()A、lslpp -f IX49035B、lslpp -fB U437542C、instfix -f IX49035D、instfix -ik IX49035

单选题A system administrator has edited the necessary files for setup of an AIX system to serve as a bootp server.  Which of the following commands is required to complete the activation?()Atelinit -qBstartsrc -s bootpdCrefresh -s inetd

单选题A system administrator has determined that a recently applied APAR needs to be removed. Which of the following installp options will remove the APAR?()AcleanupBcommitCdeinstallDreject

单选题A system administrator has just finished upgrading a system to AIX 5.2. If there are future problems, the system administrator would like to add an entry to the AIX errorlog to record this event. Which of the following commands can be issued for this purpose?()A/usr/bin/errmsg System upgraded to AIX 5.2B/usr/bin/errlog System upgraded to AIX 5.2C/usr/bin/errupdate System upgraded to AIX 5.2D/usr/bin/errlogger System upgraded to AIX 5.2

单选题A system administrator has placed an AIX base media CD-ROM in a server and initiated a reboot. The server has an ascii terminal attached to it. Which key or key combination must the administrator press to initiate the maintenance mode?()A5BMCF8DCtrl-Alt-Delete

单选题An administrator is planning an upgrade of a major software package on an application server. The software has been tested successfully in a test environment and it is ready to go into production.  Which of the following steps should the administrator take next?()A Identify necessary operating system updatesB Implement the changeC Document the changeD Schedule system down time

单选题A system was rebooted and is taking a long time to return. The administrator has logged into the HMC and sees reference code 0c9. What does this mean()?AThe system is configuring a device.BA system initiated dump has started.CThe system is varyingon a volume group.DThe system is running an inbuilt self test.

单选题An administrator is notified that a resource group has failed over from the home node, Node1 to a standbynode, Node2 and that Node1 has been powered off. Upon restarting Node1 the administrator checks the AIXerror log and the cluster.log Which of the following is the most likely cause of the failure of Node1?()AThe operating system crashedBA disk failure forced a volume group off lineCThe System Resource Controller executed a system haltDThe topology services daemon has crashed due to an ODM mismatch

单选题A system administrator has filesystems that should not be mounted during system startup. How can the system administrator prevent the /data filesystem from being mounted during subsequent boots?()Amount -no /dataBchfs -A no /dataCmount -t nfs /dataDchfs -a type=nfs /data