单选题What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE()?A2B4C8D16

单选题
What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE()?
A

2

B

4

C

8

D

16


参考解析

解析: 暂无解析

相关考题:

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE?() A.2B.4C.8D.16

What is the maximum number of CTI ports for a Cisco Unified Contact Center Express 4.0 Standard deployment? ()A、150  B、200  C、300  D、varies based on the number of expansion servers used  E、varies based on the number of applications configured

What is the typical number of trunks in a Call Center?()A、equal to half the number of IVR ports  B、greater than the number of IVR ports plus the number of agent phones  C、less than or equal to the number of IVR ports plus the number of agent phones  D、twice the number of IVR ports plus the number of agent phones

What is the maximum number of CTI ports for an IPCC Expess Standard deployment? ()A、150 B、200 C、300 D、Depends upon how many expansion servers are used E、Depends upon the number of applications configured

The "1000" in 1000BaseT cabling represents which of the following?()A、The theoretical maximum cable lengthB、The theoretical maximum bandwidthC、The theoretical port limit of the cableD、The quality level of the copper wiring used

A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A、1B、7C、15D、31

A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports of an HS22 blade server can support if the blade does not have any expansion blades attached?()A、8B、6C、4D、2

What are  minimum and maximum number of extent pools on an IBM System Storage DS8800 with 64 physical disks()A、the minimum is 1 and the maximum is 8B、the minimum is 2 and the maximum is 8C、the minimum is 2 and the maximum is 16D、the minimum is 1 and the maximum is 64

What is the theoretical maximum number of logical ports that a one port of a 2-port 10Gb IVE can provide if no VIO Server is connected to the IVE()? A、2B、4C、8D、16

An administrator is trying to extend an existing volume group with a new hard disk, but the extendvg command returns the following error. 0516-1162 /usr/sbin/extendvg. Warning, The Physical Partition Size of 64 requires the creation of 8924 partitions for hdisk11. The limitation for volume group datavg is 1016 physical partitions per physical volume. Use chvg command with -t option to attempt to change the maximum Physical Partitions per Physical volume for this volume group. The chvg -t may or may not allow the extendvg command to succeed. What is the implication of using this option?()A、It reduces the maximum file size allowed within the given volume group.B、It reduces the maximum number of files allowed within the given volume group.C、It reduces the maximum number of logical volumes allowed within the given volume group.D、It reduces the maximum number of physical volumes allowed within the given volume group.

A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports an HS22 blade server can support if the blade does not have any expansion blades attached?()A、8 B、6 C、4 D、2

Metro Mirror pairs are set up between volumes in LSSs, usually in separate locations anddifferent disk subsystems. These logical paths are defined over physical links between the disksubsystems. What is the maximum number of logical paths per physical link?()A、128B、256C、512D、1024

What is the objective of the superstrict option that can be used when creating mirrors?()A、Allows the mirror partitions to spread across a maximum number of disks.B、Allows the copy of a partition to be on the same physical volume as the mirrored partition.C、Prevents partitions allocated to one logical volume mirror from sharing a physical volume with partitions from another logical volume mirror.D、Forces copies of logical partitions to be housed on different physical volumes, while allowing a single physical volume to be shared by logical volume mirrors.

An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A、 4 B、 16 C、 20 D、 32

单选题What is the maximum number of CTI ports for an IPCC Expess Standard deployment? ()A150 B200 C300 DDepends upon how many expansion servers are used EDepends upon the number of applications configured

单选题A prospect is considering a BladeCenter H chassis with the Multi-Switch Interconnect Modules. The number of Ethernet ports is important to them. What is the maximum number of Ethernet ports an HS22 blade server can support if the blade does not have any expansion blades attached?()A8 B6 C4 D2

单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1.  If this change is made what is the maximum number of logical ports, across both port groups,  that the IVE adapter can provide? ()A 4B 16C 20D 32

单选题An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()A 4 B 16 C 20 D 32

单选题The "1000" in 1000BaseT cabling represents which of the following?()AThe theoretical maximum cable lengthBThe theoretical maximum bandwidthCThe theoretical port limit of the cableDThe quality level of the copper wiring used

单选题What formula do you use to calculate the number of Voice Gateway ports? ()AErlang A  BErlang B  CErlang C  DIVR ports + agent phones

单选题What is the first step that you would use Cisco Product Advisor for when selecting a router for an Edge solution?()A determine types of protocols to be supportedB determine the environment in which the router will be usedC select the number of WAN ports requiredD select the number of LAN ports required

单选题What is the first step that you would use Cisco Product Advisor for when selecting a router for an Edge solution?()Adetermine types of protocols to be supportedBdetermine the environment in which the router will be usedCselect the number of WAN ports requiredDselect the number of LAN ports required

单选题What formula do you use to calculate the number of agents in a Call Center?()AErlang B  BErlang C  CAHT * BHCA  DVG ports + IVR ports

单选题A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()A1B7C15D31

单选题What formula do you use to compute the number of IVR ports?()AErlang B BErlang C CAHT * BHCA DVG ports + CTI ports

单选题An administrator is configuring cross-site LVM and wants to ensure that logical volume copies are always onseparate disks. When creating a new logical volume, how could the administrator ensure that this requirement is achieved?()ASet the allocation policy to strictBSet the allocation policy to superstrictCSet the Maximum Number of Physical Volumes to 2DSet the Number of Copies for each logical partition to 2

单选题What is the maximum number of CTI ports for a Cisco Unified Contact Center Express 4.0 Standard deployment? ()A150  B200  C300  Dvaries based on the number of expansion servers used  Evaries based on the number of applications configured