单选题A customer wants a configuration for a new system that includes Reserve CoD.  Which of the following systems would be the most appropriate to configure for them?()Ap5-550Bp5-520CpSeries p650DpSeries p630

单选题
A customer wants a configuration for a new system that includes Reserve CoD.  Which of the following systems would be the most appropriate to configure for them?()
A

p5-550

B

p5-520

C

pSeries p650

D

pSeries p630


参考解析

解析: 暂无解析

相关考题:

A customer is deploying a new Junos Pulse Access Control Service and has completed the initial boot configuration as prompted using a serial connection. The customer now wants to complete the rest of the configuration using the admin GUI.Into which port on the Junos Pulse Access Control Service should the customer plug the network cable to enable access to the admin GUI?()A. the internal interfaceB. the external interfaceC. the management interfaceD. the console interface

A customer wants to create a custom Junos Pulse configuration. Which two are required?() A. Connection setB. Configuration setC. Custom installerD. Component set

A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers.What configuration setting does the storage specialist need to highlight?()A. increase the buffer credits on the HBAsB. increase the number of device logins on the ESX serversC. additional paths will be required between the servers and storageD. multipath option on the ESX servers should be changed to round-robin

A customer has two single cluster IBM TS7700 Virtualization Engines at the same site. The customer wants to move one to a remote site and set up a grid configuration with the two clusters. The customer has fibre between the two sites. What is the most important factor to consider when planning the new configuration?()A. operator trainingB. cache size of the two clustersC. fibre bandwidth capability between the sitesD. number of stacked tape drives attached to each cluster

A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?() A. disaster recovery strategyB. the number of IOPS requiredC. the capacity of each hard driveD. how the database will be backed up

A customer is deploying a new Junos Pulse Access Control Service and has completed the initial boot configuration as prompted using a serial connection. The customer now wants to complete the rest of the configuration using the admin GUI.Into which port on the Junos Pulse Access Control Service should the customer plug the network cable to enable access to the admin GUI?()A、the internal interfaceB、the external interfaceC、the management interfaceD、the console interface

A customer has two single cluster IBM TS7700 Virtualization Engines at the same site. The customer wants to move one to a remote site and set up a grid configuration with the two clusters. The customer has fibre between the two sites. What is the most important factor to consider when planning the new configuration?()A、operator trainingB、cache size of the two clustersC、fibre bandwidth capability between the sitesD、number of stacked tape drives attached to each cluster

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

A customer wants to add a new application to their existing IBM System Storage DS5300. Theyexpect that the new application will require a minimum of 15,000 additional IOPS. What toolshould be used to determine what additional disk is required to effectively add the newapplication?()A、eConfigB、Disk MagicC、Capacity MagicD、Tivoli Storage Productivity Center for Data

A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()A、perform a Disk Magic study B、review eConfig with a technical specialist C、confirm that the customer has enough ports available in the SAN infrastructure D、submit configuration to IBM System Storage Interoperability Center for validation

A customer is planning to upgrade two VMware ESX servers from 3.5 to 4.1 after recently installing a new XIV Storage System. Each server has 4 HBAs connected to redundant fabrics for a total of 4 paths per server to storage. The customer wants to increase the throughput available to the ESX servers. What configuration setting does the storage specialist need to highlight?()A、increase the buffer credits on the HBAsB、increase the number of device logins on the ESX serversC、additional paths will be required between the servers and storageD、multipath option on the ESX servers should be changed to round-robin

You have successfully sold and installed your customer’s System x solution. Sometimes, the overall succeed of a sale depends on how well you have trained your customer to support their new hardware. Please consider the following tools. Which one would be the best for protectively determining a server outage, and contacting the system administrator about the outage?()A、CDATB、Configuration and Options Guide (COG)C、Physical Alarm Sounding in Data CenterD、IBM Systems Director

A customer wants to upgrade an existing pSeries system.  In addition to retrieving the IBM configuration records, what else should be done to ensure an accurate upgrade quote is provided?()A、Request that the pSeries technical specialist provide the discount percentage to the customer.B、Run both eConfig and PCRS6000 to ensure that both configurators provide the same upgrade quote.C、Confirm with the customer that the installed inventory accurately reflects what is actually installed.D、Provide options to the customer so they can choose the most appropriate upgrade for their environment.

A customer has a POWER6 520 system with 6 partitions. They plan to upgrade their system and need to determine the current hardware configuration of the partitions before making any upgrade decisions. What is needed to read the exported system plan and design the new system?()A、e-ConfigB、System Planning Tool (SPT)C、IBM Workload Estimator (WLE)D、IBM Performance Monitor (PM)

A customer wants a configuration for a new system that includes Reserve CoD.  Which of the following systems would be the most appropriate to configure for them?()A、p5-550B、p5-520C、pSeries p650D、pSeries p630

A customer wants to run a Cluster 1600 configuration with multiple p655 servers.  They are using the new High Performance Switch for the high-speed interconnection between nodes.  Which of the following is the only supported cluster management software?()A、CSMB、PSSPC、GPFSD、HACMP

A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility.  Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()A、 PowerVM Standard Edition on POWER6 hardwareB、 PowerVM Standard Edition with POWER5 hardware C、 PowerVM Enterprise Edition with POWER6 hardwareD、 PowerVM Enterprise Edition with POWER5 hardware

A customer has an IBM System Storage DS5000 and needs to add more disk drives to the unit.There is no record of the configuration for this machine. How can the configuration be retrieved soan upgrade can be configured?()A、use Storage Manager to export the system profileB、create a configuration ineConfig and provide proof of purchaseC、use the IBM Standalone Systems Configuration Tool (SSCT) to recreate the configurationD、have the customer contact the IBM AAS coordinator to retrieve a copy of the originalconfiguration

The customer has an older storage array and is looking to migrate data that currently exists onover 100 73 GB FC drives to a new IBM System Storage DS5020. The customer states that theyhave only 3 TB of data and wants to consolidate on to fewer higher capacity drives. There are sixapplication servers running multiple applications and operating systems utilizing the storagesystem. What would be the next step to accurately identify the new storage configuration?()A、initiate a Disk Magic studyB、initiate a Capacity Magic studyC、runiometer on the current environmentD、utilize the IBM Disk capacity planner toolkit

A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?()A、disaster recovery strategyB、the number of IOPS requiredC、the capacity of each hard driveD、how the database will be backed up

Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()A、The customer is looking for a fibre SAN solution to increase reliability and performance.B、The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.C、The customer is cost-conscious and is looking for a centralized storage solution.D、The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.

A customer wants to create a custom Junos Pulse configuration. Which two are required?()A、Connection setB、Configuration setC、Custom installerD、Component set

多选题A customer wants to create a custom Junos Pulse configuration. Which two are required?()AConnection setBConfiguration setCCustom installerDComponent set

单选题A customer has a POWER6 520 system with 6 partitions. They plan to upgrade their system and need to determine the current hardware configuration of the partitions before making any upgrade decisions. What is needed to read the exported system plan and design the new system?()Ae-ConfigBSystem Planning Tool (SPT)CIBM Workload Estimator (WLE)DIBM Performance Monitor (PM)

单选题A customer wants to deploy a centralized storage system to support a new database. Which of the following factors should the storage specialist consider first?()Adisaster recovery strategyBthe number of IOPS requiredCthe capacity of each hard driveDhow the database will be backed up

单选题A customer wants to migrate their existing cluster onto new POWER6 hardware, and in addition requires thecluster to be migrated from PowerHA version 5.3 to 5.5. Given that AIX 6.1 and PowerHA 5.5 filesets arealready installed in the new hardware, which of the following methods would allow the customer to maintaintheir current cluster configuration?()AAdd the new nodes to the existing cluster, and perform a rolling migration and remove the original nodesfrom the clusterBAdd the new nodes to the existing cluster, and perform a non-disruptive upgrade and remove the originalnodes from the cluster.CCreate a snapshot of the existing cluster and apply the snapshot to the new cluster. Start cluster serviceson the new cluster and stop the original clusterDCreate a snapshot of the existing cluster and apply the snapshot to the new cluster. Stop cluster serviceson the original cluster and start on the new cluster