单选题When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().AdehydratedBpurgedCpluggedDevacuated
单选题
When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().
A
dehydrated
B
purged
C
plugged
D
evacuated
参考解析
解析:
暂无解析
相关考题:
Frequent ______ is important: fixing or changing faulty parts of the propulsion system when necessary.
When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
第一组An automatic system usually consists of a control system and an information system. A control system is a system which measures the condition of some entity and, with the information, governs the state of a variable; i.e., speed, temperature, pressure, position, etc. The open-loop system is the simplest form. a control system may assume. It is distinguished from the closed-loop system by the lack of an input which measures the state of the controlled variable; such an input is called a feedback. In modern ships the open-loop system has practically disappeared and the closed-loop system which operates with a feed-back is extensively used. An information system serves the parallel function of monitoring system or plant performance. The monitoring function may serve a number of purposes; specifically it may indicate values of controlled variables to guide remote control operations, warn of off-limit conditions and provide record of performance. In many cases a visual and audible alarm may be provided to warn of off-limit conditions on board ship and, associated with this, the important variables will be recorded on demand. The automatic control system can be more sophisticated by incorporating digital-processing equipment, that is, a computer. This computer is usually fed with signals from all sensors. It scans the values of the sensors and generates alarm signals for off-limit conditions, acting as a super-supervisor. Sometimes, it can even make necessary and take the necessary action to optimize performance without human intervention.The closed-loop system differs from the open-loop system byA.the lack of a feedbackB.the presence of a feed backC.the lack of a computerD.the presence of a computer
Which of the following statements best describes the relationship between a logical volume and a journaled file system (JFS)?() A.Increasing the size of a logical volume also increases the size of the file systemB.Reducing the size of a logical volume requires reducing the size of the file system firstC.Increasing the size of a file system requires increasing the size of the logical volume firstD.Increasing the size of a file system also increases the size of the logical volume when necessary
Which of the following statements is NOT true?()AThe open field system provided a good opportunity to experiment.BThe open field system wasted land.CThe open field system was wasteful of labor and time.DThe open field system made livestock farming difficult.
Which of the following statements is NOT true?()A、The open field system provided a good opportunity to experiment.B、The open field system wasted land.C、The open field system was wasteful of labor and time.D、The open field system made livestock farming difficult.
在网络体系结构中,OSI表示()A、Open System InterconnectionB、Open System InformationC、Operating System InterconnectionD、Operating System Information
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题Purging air from a hydraulic system is necessary when()Aadding small amounts of oil to the systemBthe system has been overheatedCthe system has been drained and then filled with new oilDthe system has been idle for a long period of time
单选题Which of the following statements is NOT true?()AThe open field system provided a good opportunity to experiment.BThe open field system wasted land.CThe open field system was wasteful of labor and time.DThe open field system made livestock farming difficult.
单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling
单选题In a refrigeration system, the refrigerant absorbs the latent heat of vaporization in the().AcompressorBcondenserCreceiverDevaporator
单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().Athe compressor suction pressure is not too highBall air is purged from the pump and charging fittingsCthe high pressure cutout switch is held open to prevent accidental startingDthe condenser is completely shutdown first
单选题When it is necessary to open a refrigeration system for repairs and the system will be open for more than a few minutes, the open ends of the system should be ().AdehydratedBpurgedCpluggedDevacuated
单选题The function of () in a refrigeration plant using Freon is to move moisture from all refrigeration system.AfilterBfilter drierCheat exchangerDair cooler
单选题When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().Aalways be wide open when the compressor restartsBcontinue to operate as if the system were in operationCremain open until evaporator pressure equalizes, then close until the compressor restartsDalways be completely closed until the compressor restarts
单选题Refrigerant is circulated through a refrigeration system by the ().AcompressorBcondenserCexpansion valveDevaporator
单选题One cause of high head pressure occurring in a refrigeration system can be ().Ainsufficient cooling water flow to the condenserBa low refrigerant charge in the systemCthe liquid valve is open too muchDhigh evaporator superheat
单选题Moisture in a refrigeration system can cause ().Afreezing the expansion valve closedBcorrosion of system pipingCimproper temperature regulationDall of the above
单选题When the refrigeration demand is small,()Athe expansion valve will move toward the wide open positionBthe expansion valve will move toward the closing positionCthe feeler bulb will conveys the high temperatureDthe superheat degree will raise
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser
单选题When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().Aincrease the amount of cooling water to the condenserBdecrease the amount of cooling water to the condenserCadd more refrigerant to the systemDremove some refrigerant from the system
单选题In a refrigeration system, if the cooling water to the condenser fails, the().Abox temperature solenoid valve will closeBexpansion valve will closeCcompressor will shutdownDking valve will open
单选题To correct the condition of slugging and flooding back in a refrigeration system, it may be necessary to ().Are-adjust the discharge pressureBclean the expansion valve screenCadd refrigerantDadjust the expansion valve
单选题Which of the listed refrigeration system components keeps the refrigerant circulating through the system?()AExpansion valveBCondenserCEvaporatorDCompressor
单选题Which of the following statements best describes the relationship between a logical volume and a journaled file system (JFS)?()AIncreasing the size of a logical volume also increases the size of the file systemBReducing the size of a logical volume requires reducing the size of the file system firstCIncreasing the size of a file system requires increasing the size of the logical volume firstDIncreasing the size of a file system also increases the size of the logical volume when necessary
单选题A pressure drop in the liquid line of a refrigeration system may cause()Athe solenoid valve to seizeBthe compressor to huntCflash gas to form in the liquid lineDthe expansion valve to freeze open