单选题When fire pumps are used for other than firefighting service,each pipe connecting the other service (except for branch lines used for deck washing) must have a().Acheck valve installed in the lineBshut off valve at a manifold near the pumpCquick disconnect union within ten feet of the pumpDregulator in the line set at 125 psi

单选题
When fire pumps are used for other than firefighting service,each pipe connecting the other service (except for branch lines used for deck washing) must have a().
A

check valve installed in the line

B

shut off valve at a manifold near the pump

C

quick disconnect union within ten feet of the pump

D

regulator in the line set at 125 psi


参考解析

解析: 暂无解析

相关考题:

In some restaurants, food and service are worse than ___ used to be. A.theyB.itC.themD.those

Which of the following statements concerning the lubrication of diesel propulsionengines used in vessels over 300 gross tons is most accurate? ( )A.Lubrication systems using engine driven lube oil pumps do not require any additionalindependent arrangement when such arrangements have been proven reliable.B.The use of engine driven pre-lube pumps is permitted on vessels with propulsionsystems developing less than 500 shaft horsepower.C.When forced lubrication is used for propulsion engines , one independently drivenstandby pumps is to be provided in addition to the necessary pumps for normaloperation.D.Lubrication systems where two oil coolers are fitted require a minimum of twotemperature control devices which may be actuated by similar sensors.

A fire pump may be used for other purposes if ______.A.the other services are run off a reducing station with a pressure gageB.one of the required pumps is kept available for use on the fire main system at all timesC.no relief valves are installedD.all of the above conditions are met

In the event of fire in a machinery space,______.A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failedB.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishmentC.water in any form should not be used as it will spread the fireD.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel

A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main

All the crewmembers shall be at the station as required by the muster list when in firefighting drill______minutes after hearing the alarm,and the duty engineer shall be able to make the fire pumps available with______minutes.A.2/5B.2/3C.3/2D.2/2

Fire axes required on MV MODU’s must be stored in the enclosure for fire hoses with the location marked ______.A.Fire Axe LocationB.Hose Station No. …C.Fire Station No. …D.Firefighting Equipment

单选题Although lube oils used in the main lubricating service systems should have a relatively high flash point to avoid ignition, they can create smoke and fire hazards when they()Aare exposed to a vacuumBcome in contact with extremely hot surfacesCare reduced in temperature to just above the pour pointDbecome extremely agitated or aerated

单选题On a ship,a fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBa separate fire pump is available for use on the fire mainCall other services are operated by a manifold near the pumpDAll of the above

单选题There are two disadvantages to CO2 pump as a firefighting agent. One of these is the limited quantity available,and the other is().Athe lack of cooling effect on heated materialsBthat it cannot be used in a dead ship situation with no electrical power to the CO2 pumpCthat it breaks down under extreme heat to form poisonous gasesDthere is no effect on a class A fire even in an enclosed space

单选题The success of an indirect attack on a fire depends on the().Asize of the fire when initially observedBcomplete containment of the fireCcooling ability of the firefighting agentDclass of the fire

单选题According to the passage, which of the following is true of the ratios of oxygen isotopes in ocean sediments?AThey indicate that sediments found during an ice age contain more calcium carbonate than sediments formed at other times.BThey are less reliable than the evidence from rocks on land in determining the volume of land ice.CThey can be used to deduce the relative volume of land ice that was present when the sediment was laid down.DThey are more unpredictable during an ice age than in other climatic conditions.EThey can be used to determine atmospheric conditions at various times in the past.

单选题What is meant by the term overhaul in firefighting?()ASlow down the spread of fire by cooling adjacent structuresBCover the fire with foamCSmother the fire with a blanket or similar objectDBreak up solid objects to ensure that any deep seated fires are extinguished

单选题A high-velocity fog stream can be used in fire fighting situations to drive heat and smoke ahead of the fire fighters in a passageway. This technique should only be used when().Ausing a 2-1/2 inch hoseBthere is an outlet for the smoke and heatCthe fire is totally contained by the ship's structureDat least two fog streams can be used

单选题The fire pumps must be capable of delivering a total quantity of water at a defined head, not less than () of the total bilge pumping capacity.Aone-thirdBtwo-thirdsCone-fourthDtwo-fourths

单选题A fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBone of the required pumps is kept available for use on the fire main system at all timesCno relief valves are installedDall of the above conditions are met

单选题Multiple fire pumps may be used for other purposes provided that one pump is().Aon line to the fire mainBkept available for use on the fire main at all timesCcapable of being connected to the fire mainDrated at or above 125 psi

单选题An alternator switchboard has a synchroscope and synchronizing lamps, if the synchroscope is broken, which of the steps listed is the most essential before an alternator can be paralleled with the bus ()AThe breaker should be closed when one synchronizing lamp is dark and the other is brightBThe breaker should be closed when both synchronizing lamps are brightCThe frequency meter should be used to determine that the incoming alternator frequency is slightly higher than the busDA portable phase sequence indicator must be used to verify the information from the lamps

单选题Machinery driving fuel oil transfer and fuel oil service pumps must be fitted with a remote means of stopping the machinery from ().Awithin the space concernedBoutside the space concernedCthe throttle stationDwithin the fire room

单选题Which characteristic of Halon is a disadvantage when it is used as a fire extinguishing medium?()ALeaves a residueBCost,relative to other agentsCBreaks down while under prolonged storageDConducts electricity

单选题A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the().Afire hose might be damaged by cargo operationsBvessel is in portCfire-main system is not chargedDfire pumps are used for purposes other than supplying water to the fire main

单选题Which of the materials listed is used as the dynamic seal material on mechanical seals installed on most centrifugal pumps used in water service?()ACopperBCopper and carbonCCarbonDBronze

单选题Which of the following statements concerning the lubrication of diesel propulsion engines used in vessels over 300 gross tons is most accurate?()ALubrication systems using engine driven lube oil pumps do not require any additional independent arrangement when such arrangements have been proven reliableBThe use of engine driven pre-lube pumps is permitted on vessels with propulsion systems developing less than 500 shaft horsepowerCWhen forced lubrication is used for propulsion engines, one independently driven stand-by pumps is to be provided in addition to the necessary pumps for normal operationDLubrication systems where two oil coolers are fitted require a minimum of two temperature control devices which may be actuated by similar sensors

单选题A distinguishing feature of an educator, when compared to other pumps, is the ().AdischargeendbeingsmallerthanthesuctionendBsmallsizeofimpellerClackofmovingpartsDeaseatwhichthewearingringsmaybechanged

单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()ACarbon dioxide is corrosive when exposed to fireBCarbon dioxide should be applied slowly to a large engine room fireCIts total cooling effect is far greater than waterDIts smothering effect is excellent for class B fires

单选题The main steering gear must be able to steer the ship at maximum ahead service speed and be capable at this speed, and at the ships deepest service draught, of putting the rudder from 35 degrees on one side to 30 degrees on the other side within no ().Amore than 28 secondsBmore than 60 secondsCless than 28 secondsDless than 60 seconds

单选题When used to fight fire,carbon dioxide().Ais effective if used promptly on an oil fireBhas a greater cooling effect than waterCis lighter than airDis harmless to cargo and crew