单选题Multiple fire pumps may be used for other purposes provided that one pump is().Aon line to the fire mainBkept available for use on the fire main at all timesCcapable of being connected to the fire mainDrated at or above 125 psi

单选题
Multiple fire pumps may be used for other purposes provided that one pump is().
A

on line to the fire main

B

kept available for use on the fire main at all times

C

capable of being connected to the fire main

D

rated at or above 125 psi


参考解析

解析: 暂无解析

相关考题:

Because the timing of injection is crucial, _____ mounted on the camshaft, which is driven by the crankshaft are used to operate the fuel pumps, one of which is provided for each cylinder.A.gearsB.ramsC.barrelsD.cams

Besides the purpose of gaining and maintaining total control over someone, domestic abuse may be used for some other purposes.() 此题为判断题(对,错)。

As a duty engineer, as soon as your hear the fire emergency signal, you should ensure that theA.ring buoys are thrown overboardB.engines are stoppedC.fire pumps are startedD.life preservers have been issued to everyone

The closing of the exhaust valves used on a modern, large, low-speed, main propulsion diesel engine may be directly provided by_______.A.large conical springsB.compressed air pressureC.hydraulic pressureD.exhaust gas pressure

A fire pump may be used for other purposes if ______.A.the other services are run off a reducing station with a pressure gageB.one of the required pumps is kept available for use on the fire main system at all timesC.no relief valves are installedD.all of the above conditions are met

In the event of fire in a machinery space,______.A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failedB.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishmentC.water in any form should not be used as it will spread the fireD.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel

You are carrying triethylamine,methyl methacrylate and isoprene in your multiple-product tanker. Which of the following statements is true?A.Isoprene may be carried in a cargo tank adjacent to either of the other two cargoesB.Methyl methacrylate may not be carried in a tank adjacent to a pump roomC.Methyl methacrylate must usually be heated to maintain its stabilityD.Portable thermometers are not permitted to be used to take the cargo temperature of triethylamine

A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main

In an environment in which multiple VLANs have been defined on Catalyst Express 500 switches, which two statements are correct for ports that have been configured with the Smartport role of "IP Phone + Desktop"?()A、The names of the VLANs used by the SmartPorts are case insensitiveB、The ports may belong to a configurable data VLANC、The names of the VLANs used by the Smartports are not relevantD、The ports may belong to many VLANs, depending on how many PCs are connected to each port.E、The names of the VLANs used by the Smartports are case sensitive

单选题On a ship,a fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBa separate fire pump is available for use on the fire mainCall other services are operated by a manifold near the pumpDAll of the above

单选题You are ordering ship’s stores. Which statement is TRUE?().AStores such as line,rags,mattresses,linens,etc. must be treated to be fire retardantBStores certified for use on uninspected vessels may be identified by the certification number used by Underwriter's LaboratoriesCA portable container of a flammable liquid used as fuel for portable auxiliary equipment must be stowed in a paint locker or at a designated open locationDAcetylene may be in a ship's storeroom in quantities not exceeding 6000 cubic feet

单选题A cutoff valve in the fire-main system of a ship may be closed to protect the portion of the system on an exposed deck from().Adamage from crane operationsBbeing used for wash down purposesCaccidental diversion of flow to wrong locationDfreezing

单选题On a bulk chemical carrier,water should NOT be used as an extinguishing agent to fight a fire if the water may come into contact with the chemical called().Aacrylic acidBbenzeneColeumDvinyl toluene

单选题In some cases facilities may be provided for emergency overriding oil pressure shutdown, if this facility is used, adequate warning must be given to ().Athe bridge watch-keeperBthe captainCthe chief engineerDthe engine room staff

单选题You are carrying triethylamine,methyl methacrylate and isoprene in your multiple-product tanker. Which of the following statements is true? ()AIsoprene may be carried in a cargo tank adjacent to either of the other two cargoesBMethyl methacrylate may not be carried in a tank adjacent to a pump roomCMethyl methacrylate must usually be heated to maintain its stabilityDPortable thermometers are not permitted to be used to take the cargo temperature of triethylamine

单选题The minimum number and capacity of bilge pumps and fire pumps and their distributing within the ship is governed by ().AClassification Society RulesBNational requirementsCThe IMO International Convention for the Safety of Life at SeaDAll of the above

单选题When fire pumps are used for other than firefighting service,each pipe connecting the other service (except for branch lines used for deck washing) must have a().Acheck valve installed in the lineBshut off valve at a manifold near the pumpCquick disconnect union within ten feet of the pumpDregulator in the line set at 125 psi

单选题A fire pump may be used for other purposes if().Athe other services are run off a reducing station with a pressure gageBone of the required pumps is kept available for use on the fire main system at all timesCno relief valves are installedDall of the above conditions are met

单选题Any oil tanker which is not required to be provided with segregated ballast tanks in accordance with this paragraph may,however,be qualified as a segregated ballast tanker ()it complies with the other requirements of paragraphs of this Convention.Aprovided thatBon the part ofCneverthelessDnotwithstanding

单选题Which characteristic of Halon is a disadvantage when it is used as a fire extinguishing medium?()ALeaves a residueBCost,relative to other agentsCBreaks down while under prolonged storageDConducts electricity

单选题A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the().Afire hose might be damaged by cargo operationsBvessel is in portCfire-main system is not chargedDfire pumps are used for purposes other than supplying water to the fire main

多选题In an environment in which multiple VLANs have been defined on Catalyst Express 500 switches, which two statements are correct for ports that have been configured with the Smartport role of "IP Phone + Desktop"?()AThe names of the VLANs used by the SmartPorts are case insensitiveBThe ports may belong to a configurable data VLANCThe names of the VLANs used by the Smartports are not relevantDThe ports may belong to many VLANs, depending on how many PCs are connected to each port.EThe names of the VLANs used by the Smartports are case sensitive

单选题Which of the following statements concerning the lubrication of diesel propulsion engines used in vessels over 300 gross tons is most accurate?()ALubrication systems using engine driven lube oil pumps do not require any additional independent arrangement when such arrangements have been proven reliableBThe use of engine driven pre-lube pumps is permitted on vessels with propulsion systems developing less than 500 shaft horsepowerCWhen forced lubrication is used for propulsion engines, one independently driven stand-by pumps is to be provided in addition to the necessary pumps for normal operationDLubrication systems where two oil coolers are fitted require a minimum of two temperature control devices which may be actuated by similar sensors

单选题When the engine room is put in standby condition, the engineer in charge of the watch need not to()Aensure all machinery which may be used during maneuvering is in readyBensure an adequate reserve of power is available for steering gear and other requirementsCkeep the main propulsion unit controls continuously attended when in the manual mode of operationDensure all machinery which may be used during maneuvering is running stably

单选题Fuel oil transfer systems used onboard diesel propelled vessels are required to have ().Atwo fuel oil transfer pumps provided where one is to be independent of the main engineBtwo fuel oil transfer pumps, with a combined capacity exceeding the maximum consumption of the main engineCengine driven transfer pumps and only used in constant speed applicationsDthe capacity of the engine driven pump exceed the consumption rate of the engine to which it is attached

单选题The closing of the exhaust valves used on a modern, large, low-speed, main propulsion diesel engine may be directly provided by ().Alarge conical springsBcompressed air pressureChydraulic pressureDexhaust gas pressure

单选题A simplified construction plan may be included in the ship construction portfolio provided it adequately defines the().Aareas where special materials are usedBhazardous areasClocation of emergency repair equipmentDtype and strength of materials used