单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题
If the suction pressure at the refrigeration compressor is below normal, the cause can be().
A

refrigerant overcharge

B

overfeeding by the expansion valve

C

a restricted suction strainer

D

due to short cycling of the compressor


参考解析

解析: 暂无解析

相关考题:

If the refrigeration compressor crankcase is sweating, the cause may be due toA.a shortage of refrigerantB.the compressor running continuouslyC.liquid refrigerant returning to the compressorD.the compressor short cycling on the high pressure cutout

When adding oil to a refrigeration system, precautions must be taken to ensure thatA.the compressor suction pressure is not too highB.all air is purged from the pump and charging fittingsC.the high pressure cutout switch is held open to prevent accidental startingD.the condenser is completely shutdown first

Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur when the compressorA.has run continuously for a long periodB.suction pressure is below normalC.oil level is below normalD.starts after a long idle period

In the refrigeration system, a shortage of refrigerant is indicated byA.the compressor short cycling on high pressure cut out switchB.high suction pressureC.high head pressureD.bubbles in the sight glass

If the suction pressure at the refrigeration compressor is below normal, the cause can beA.refrigerant overchargeB.overfeeding by the expansion valveC.a restricted suction strainerD.due to short cycling of the compress

Sweating of the refrigeration system compressor crankcase is caused by_______ .A.too much superheatB.insufficient superheatC.suction pressure too lowD.excessive refrigerant returning to the compressor

The sensing line for the low pressure cutout switch to a refrigeration system is located ______.A.in the chill box(冰箱)B.before the receiverC.on the suction side of the compressorD.on the discharge side of the compressor

If the suction pressure for an operating refrigeration compressor is below normal, the cause may be ______.A.an excess of liquid refrigerantB.the expansion valve overfeedingC.a fouled compressor suction strainerD.the compressor short cycling

单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system

单选题When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().Aflooding backBsuperheatingCoverflowingDrecycling

单选题When adding oil to a refrigeration system, precautions must be taken to ensure that ().Athe compressor suction pressure is not too highBall air is purged from the pump and charging fittingsCthe high pressure cutout switch is held open to prevent accidental startingDthe condenser is completely shutdown first

单选题Which of the listed operations will cause an automatically controlled refrigeration compressor to restart?()AClosing of the solenoid valveBClosing of the expansion valveCAn increase in the suction pressureDDecreasing the suction pressure

单选题Insufficient refrigerant in a refrigeration plant may result in ().Ahigh discharge pressureBfrosting of the crankcaseChigh temperature of the overboard waterDlow suction pressure of compressor

单选题If the discharge valves on a refrigeration compressor are leaking badly, the compressor should ().Arun continuouslyBnot startChave high discharge pressureDshort cycle on the high pressure switch

单选题The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().Asystem is low on refrigerantBhigh pressure cutout switch is improperly adjustedCdischarge valves are leaking slightlyDdischarge valves are leaking excessively

单选题In the refrigeration system, a shortage of refrigerant is indicated by ().Athe compressor short cycling on high pressure cut out switchBhigh suction pressureChigh head pressureDbubbles in the sight glass

单选题If the head pressure of a reciprocating refrigeration compressor is excessive, ().Athe relief valve should open before the high pressure cutoutBthe relief valve should open and allow the excess refrigerant to flow to the receiverCthe high pressure cutout switch should operate before the relief valve opensDyou should close in on the suction valve

单选题If the refrigeration compressor crankcase is sweating, the cause may be due to ().Aa shortage of refrigerantBthe compressor running continuouslyCliquid refrigerant returning to the compressorDthe compressor short cycling on the high pressure cutout

单选题Foaming of the oil in a refrigeration compressor crankcase is caused by ().Arefrigerant boiling out of solution from the lube oilBliquid refrigerant flooding the compressor and systemClube oil viscosity being reduced by refrigerant dilutionDcompressor suction pressure suddenly increasing

单选题If the suction pressure at the refrigeration compressor is below normal, the cause can be().Arefrigerant overchargeBoverfeeding by the expansion valveCa restricted suction strainerDdue to short cycling of the compressor

单选题An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().Aoil foaming in the compressorBhigher than normal suction and discharge pressures with a higher box temperatureChigher than normal discharge pressure with a normal box temperatureDthe compressor to run continuously

单选题Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().Acompressor damage from improper lubricationBrefrigerant absorption by the lubricantCincreased viscosity in the lubricantDcarbon deposit on the compressor suction valves

单选题The purpose of the refrigeration system low pressure cutout switch is to ()Aprotect the compressor from liquid flood backBprotect the compressor from low discharge pressureCstart and stop the compressor upon system demandDstart the compressor after a drop in the evaporator pressure

单选题An increase in the heat load to a refrigeration system will cause ().Athe suction pressure to decreaseBthe suction temperature to increaseCincreased ice formation on the evaporator coilDexcessive short cycling of the compressor

单选题The sensing line for the low pressure cutout switch to a refrigeration system is located ().Ain the chill boxBbefore the receiverCon the suction side of the compressorDon the discharge side of the compressor

单选题Sweating of the refrigeration system compressor crankcase is caused by ().Atoo much superheatBinsufficient superheatCsuction pressure too lowDexcessive refrigerant returning to the compressor

单选题The purpose of the low pressure cut-out switch is to ().Amaintain liquid refrigerant at the suction of the compressorBmaintain a preset suction pressure to the compressorCstart and stop the compressor at preset operating pressuresDoperate at minimum efficiency

单选题When a refrigeration compressor motor fails to start, the FIRST thing that should be checked for is a ().Aloose expansion valve control bulbBlow differential setting on the H-PcutoutCblown fuse in the motor circuitDfaulty suction pressure regulator