单选题Domestic water pump is started automatically by () which operates as the water level falls to a predetermined level.Aa level controllerBa temperature switchCa pressure switchDa floating ball

单选题
Domestic water pump is started automatically by () which operates as the water level falls to a predetermined level.
A

a level controller

B

a temperature switch

C

a pressure switch

D

a floating ball


参考解析

解析: 暂无解析

相关考题:

The main propulsion diesel engine jacket water temperature rises above normal, with the raw sea suction and the expansion tank water level being normal. Which of the following problems is most likely the cause?A.Faulty thermostatic bypass valveB.Eroded zinc pencils in the heat exchangerC.Steam formation in the expansion tankD.Excessive leakage from jacket water pump seals

When received the order "Finished With Engine", which of the following operations is wrong?A.stop the L.O pump, S.W pump, jacket water cooling pump immediatelyB.stop the F.O booster pumpC.engage the turning gear, turn the main engineD.open the main engine scavenge air trunk's drain cocks

If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.A.high steam pressure in the boilerB.abnormally high feed-water temperatureC.abnormally high boiler water temperatureD.steam demand exceeding feed pump capacity

A centrifugal pump may fail to deliver water when first started if the ______.A.water seal pipe is pluggedB.pump is not primedC.seal ring is properly locatedD.impeller is flooded

Cooling water pump

A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()A、viB、mkitabC、telinitD、startsrc

单选题Each inert gas system gas main must have an automatic shut down valve at the outlet of the gas production plant. This valve must close automatically upon().Acargo pump failureBblower failureCdeck seal low water levelDlow inert gas temperature

单选题Which of the following pumps will most affect oily water separator performance and give the worst result?()Areciprocating pumpBvane pumpCscrew pumpDcentrifugal pump

单选题The purpose of a temperature sensing device installed in the stack of a small automatically fired auxiliary steam boiler is to secure the oil burner()Ain the event of a flame failureBin the event of a stack fireCwhen the water level reach the crown sheetDwhen the feed pump discharge pressure drops to a preset minimum

单选题Which of the following pumps is most suitable for an oily water separator?()Areciprocating pumpBvane pumpCmono pumpDaxial-flow pump

单选题The hot expanding gas rotates the blades of the exhaust turbine, thus giving out large part of its power, which drives ().Athe oil separatorBthe fresh water generatorCthe compressorDfire pump

单选题The domestic fresh water pump starters are controlled by pressure switches which operate when the pressure in the tank varies within predetermined limits as water is drawn offThe word “which” means ().AstartersBpressure switchesCpressureDwater

单选题The ()pump is usually used as the bilge feed pump to an oily water separator.AturbineBscrewCvaneDejector

单选题In a domestic fresh water system, the pump starters are controlled by () switches which operate when the pressure in the tank varies within predetermined limits as water is drawn off.Awater levelBwater flowCtemperatureDpressure

单选题In the event of failure of an auxiliary such as a lubricating pump, the standby pump is started and put on the line automatically“the line” in this sentence refers to()Afuel manifoldBlubricating pipe lineCauxiliary engine pipe lineDgenerator output line

单选题As soon as a diesel engine has started, which of the listed engine operating parameters should be checked FIRST?()AExhaust temperaturesBRaw water pressureCLube oil pressureDAir box pressure

单选题Which pump installation would require an external source of sealing water?()AMain circulator pump jacket water coolingBSalt water service pumpCAuxiliary condensate pumpDBilge pump

单选题When oily water separator is operating, which measure () is wrong.Apay attention to operating parametersBrenew and clean separating units in timeCcheck oil level in separator to prevent overloadDcheck separating effect, if it is bad, flush with large capacity water pump

单选题In the two stage flash distilling plant, which of the pumps listed is vented to the shell of the second stage in order to remove vapor from the pump suction?()ACondenser circulating water pumpBFeed-water heater drain pumpCDistillate pumpDAir ejector condenser drain pump

单选题Excessive vibration of an automatically fired auxiliary boiler can be caused by ()Aair or water in the furnaceBcombustion pulsesCfuel oil pump failureDflame failure

单选题Which of the listed statements is correct concerning the starting of centrifugal pumps?()AThey should always be started with the discharge valve closedBThey should always be started with the discharge valve openedCA priming pump is always required to flood the impeller suctionDThey should always be started with the sealing line valves closed

单选题A centrifugal pump may fail to deliver water when first started if the ().Awater seal pipe is pluggedBpump is not primedCseal ring is improperly locatedDimpeller is flooded

单选题Excessive air leakage into the suction side of a centrifugal pump would be indicated by which of the following operational problems?()AThe pump delivers full capacity when started, but gradually slackens off toan abnormally low flowBThe pump packing gland overheats after short operating periodsCThe motor over-current protective device continually shuts the pump downDPounding noises can be heard at the pump suction chest

单选题Improper maintenance of the fuel oil burners in an automatically fired auxiliary boiler, could result in ()Aincreased fuel consumptionBincreased feed water consumptionCfuel pump failureDcombustion control system failure

单选题Water accumulation in the cylinder of a secured engine is an indication that the ()Asoft water pump was not secured along with the engineBjacket water thermostat has failedCcylinder liner may be crackedDraw water pump is over-speeding just prior to engine shutdown

单选题If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().Ahigh steam pressure in the boilerBabnormally high feed water temperatureCabnormally high boiler water temperatureDsteam demand exceeding feed pump capacity

单选题Which of the following liquids can ordinarily be discharged overboard without being processed through an oily water separator?()ACargo tank ballastBSegregated ballastCEngine room bilgesDCargo pump room bilges