单选题A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()Aan electrical interlock systemBan automatic paralleling trip switchCthe synchronizing oscilloscopeDthe reverse current relay

单选题
A diesel driven emergency generator is prevented from being paralleled with the ships service generators by ()
A

an electrical interlock system

B

an automatic paralleling trip switch

C

the synchronizing oscilloscope

D

the reverse current relay


参考解析

解析: 暂无解析

相关考题:

For most diesel propulsion and generator engines, the over-speed trip device will stop the engine byA.moving the governor control to stopB.shutting off the lubricating oil supplyC.tripping the governor emergency stop leverD.shutting off the fuel supply

When the ships is going to enter into the harborA.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest form high level one to lower level oneD.test emergency generator

describe the procedure to start an emergency generator ?

When the ship is going to enter into the harbor, ____.A.change from heavy fuel oil to diesel oil for main engineB.pumping out bilge waterC.change sea chest from high level one to lower level oneD.test emergency generator

The emergency generator or emergency battery is connected to _______on most large ships.A.distribution boardsB.section boardsC.emergency switch boardsD.main switch boards

It ______ for an emergency generator to require paralleling.A.is not usualB.is usualC.is necessaryD.is not impossible

A generator is prevented from becoming motorized by the use of a/an ______.A.over-speed tripB.reverse power relayC.back pressure tripD.governor controls

The storm prevented me().A、to go outB、to going outC、from being outD、from going out

单选题When the ship is going to enter into the harbor,()Achange from heavy fuel oil to diesel oil for mail engineBpumping oil bilge waterCchange sea chest form high level one to lower oneDtest emergency generator

单选题When can routine communications be resumed on a frequency or channel on which radio silence has been imposed? ()AAfter determining that the frequency or channel appears to be no longer in useBAfter determining that geographic distance from the distress situation will prohibit any other signal from interfering with emergency communicationsCAfter the Rescue Coordination Center transmits a message on the frequency or channel being used for emergency communications stating that such traffic has concludedDRoutine communications can resume if,in the Master's opinion,communications on that frequency or channel will not interfere with emergency communications

单选题When can routine communications be resumed when radio silence has been imposed?()AAfter determining that the frequency or channel appears to be no longer in useBAfter determining that geographic distance from the distress situation will prohibit any other signal from interfering with emergency communicationsCRoutine communications can resume after the Rescue Coordination Center transmits a message on the frequency or channel being used for emergency communications stating that such traffic has concludedDIf,in the Master's opinion,communications on that frequency will interfere with emergency communications

单选题For most diesel propulsion and generator engines, the over-speed trip device will stop the engine by ()Amoving the governor control to stopBshutting off the lubricating oil supplyCtripping the governor emergency stop leverDshutting off the fuel supply

单选题You have two listener processes, named L1 and L2. Both the listener processes are currently functional. While viewing the listener.ora file on your database server, you find the following entry: PASSWORDS_L1 = (1sanfrjp43) What would be the impact of this setting?()AThe listener process named L1 will disconnect the unauthorized users.BThe listener process named L1 will be prevented from being started by unauthorized users. CThe listener process named L1 will be prevented from being stopped by unauthorized users. DThe listener process named L1 will be prevented from being reloaded by unauthorized users.EThe listener process named L1 will be prevented from accepting connections from unauthorized users.

单选题An emergency diesel generator should automatically shut down in the event of ()Adangerous over-speedingBa loss of lube oil pressureCactivation of the fixed CO2 system for the emergency generator spaceDall of the above

单选题Cooling water pumps driven by direct reversing diesel engines are usually of the straight impeller vane type pump with a concentric housing to()Afacilitate bi-directional operationBprovide the greatest pump efficiencyCprevent pump clogging from marine growthDprevent cavitation at the pump outlet

单选题The load limitation of governor should be reduced when ship navigating at sea, the main reason is to()Aprevent the diesel engine surgingBprevent governor from being damaged because of swingCreduce the probability of the crank shaft being torsional vibrated and resonatedDprevent the main engine being overload or overspeed

单选题An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every ()AweekB2 weeksCmonthD3 months

单选题()of the following need not be entered in the official logbook?AThe testing of the internal combustion engine driven emergency generator at least once each month the vessel is navigatedBThe testing of storage betteries for emergency lighting and systems once each 6 months the vessels is navigatedCThe actual draft when the vessel arrives in salt water after department a portDThe testing of the line-throwing appliance once every 3 months

单选题The booster pump, which supplies diesel oil to() , should have a possibility of being powered by compressed air or by emergency power.Athe main enginesBthe auxiliary enginesCthe emergency generator engineDthe auxiliary engines and the main engine(s)

单选题Combustion gases formed in the cylinder of a diesel engine are prevented from blowing past the piston by ()Acylinder valvesBcompression ringsCpiston skirtsDoil rings

单选题A diesel generator has just been paralleled with an AC turbo-generator, but the load can not be properly divided.This could be caused by()Aan incorrect diesel generator governor speed droop adjustmentBa faulty reverse power relay within the main circuit breaker assemblyCunsynchronized isochronous load distribution adjustmentsDa different speed setting on each unit

单选题Standby or emergency diesel generator day tanks should always be kept full to reduce the possibility of()Asediment contaminationBfuel filter cloggingCmoisture formationDinadequate transfer pump suction head

单选题The emergency generator or emergency battery is connected to() on most large ships.Adistribution boardsBsection boardsCemergency switch boardsDmain switch boards

单选题A generator is prevented from becoming motorized by the use of a/an ().Aover-speed tripBreverse power relayCback pressure tripDgovernor controls

单选题It () for an emergency generator to require paralleling.Ais usualBis not usualCis necessaryDis not impossible

单选题When the ships is going to enter into the harbor,().Achange from diesel oil to heavy fuel oil for mail engineBpump out bilge waterCchange sea chest form lower level one to high level oneDtest emergency generator

单选题On a ship,each emergency generator must be tested at least once each().AweekBmonthCthree monthsDsix months