单选题Which of the following can help prevent data loss on a RAID array in the event of a power failure?()AUsing a RAID mirrorBA battery backed write cacheCUsing RAID with parityDA battery backed read cache
单选题
Which of the following can help prevent data loss on a RAID array in the event of a power failure?()
A
Using a RAID mirror
B
A battery backed write cache
C
Using RAID with parity
D
A battery backed read cache
参考解析
解析:
暂无解析
相关考题:
Which of the following RAID levels can withstand the simultaneous loss of two physical drives in an array?() A. RAID 0B. RAID 3C. RAID 5D. RAID 10
RAID 5 can be BEST described as which of the following?()A、Mirroring with stripingB、Striping with dedicated parityC、Striping with distributed parityD、Independent disks with shared parity
Which of the following RAID levels provides the BEST read and write performance?()A、RAID 0B、RAID 1C、RAID 5D、RAID 10
A customer is building a database server, and the server does sequential write most of the time. They are planning to use an IBM x445 and a ServeRAID-6M adapter. Which of the following fault tolerant RAID levels will perform best for sequential write?()A、RAID-5 with cache write backB、RAID-1E with cache write backC、RAID-10 with cache write thruD、RAID-50 with cache write thru
A police department is interested in disk storage for a video application. Once the data is stored todisk it will be backed up to tape for long term storage. The array must have the highestperformance. Redundancy is not required. What RAID level will meet this requirement?()A、RAID 1B、RAID 0C、RAID 5D、RAID DP
An administrator is required to maintain maximum redundancy for 1TB of accounting files. Which of the following is the BEST option available to the administrator?()A、Create a RAID 5 array using eight 300GB disks.B、Create a RAID 10 array using six 300GB disks.C、Create a RAID 5 array using ten 300GB disks.D、Create a RAID 10 array using eight 300GB disks.
Which of the following RAID levels can withstand the simultaneous loss of two physical drives in an array?()A、 RAID 0B、 RAID 3C、 RAID 5D、 RAID 10
A new storage array must be configured for a database server. This array will store transaction logs that are always being written. Which of the following RAID solutions would provide fault tolerance and fast write operations without the use of parity? ()A、 RAID 0B、 RAID 3C、 RAID 6D、 RAID 10
Which of the following can help prevent data loss on a RAID array in the event of a power failure?()A、Using a RAID mirrorB、A battery backed write cacheC、Using RAID with parityD、A battery backed read cache
An administrator is required to maintain space for 750GB of user data. Which of the following is the BEST option available to the administrator?()A、Create a RAID 5 array using five 200GB disks.B、Create a JBOD using four 200GB disks.C、Create a RAID 1 array using six 200GB disks.D、Create a RAID 5 array using three 200GB disks.
Which of the following would be the BEST configuration when using seven SCSI drives in order to have full fault tolerance?()A、 RAID 0+1B、 RAID 0C、 RAID 1D、 RAID 5
A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()A、Increase the memory on the server.B、Reconfigure drives to a RAID 0+1.C、Install a battery backed write cache module in the system.D、Instruct the user to save to the local system instead of to the server.
A customer has a file server with RAID-5 using 8KB random I/Os, with 67% reads and 33% writes. How should the disk controller cache be configured for optimal performance?()A、Use write-back cacheB、Use write-back cache with battery backupC、Use write-through cache with disk caching enabledD、Use write-through cache with disk caching disabled
A banking customer is confused about RAID protection. Which of the following are characteristic of RAID-6?()A、Double drive failure in an array and extremely high data fault toleranceB、Double drive failure in an array and more total storage capacity than RAID-5C、Extremely high data fault tolerance and higher performance than RAID-5D、Higher performance than RAID-5 and more total storage capacity than RAID-5
A customer has a file server using RAID-5 with 8KB sequential write operations. How should the disk controller cache be configured for optimal performance and data integrity?()A、Use write-back cache with battery backup enabledB、Use write-through cache with battery backup enabledC、Use read-back cache with battery backup enabledD、Use read-through cache with battery backup enabled
You administer a SQL Server 2008 instance. You plan to deploy a new database that has the following capacity requirements: 275 GB for the database data file; 50 GB for the transaction log file. The storage array has six 100-GB disk drives available for the database. The disks are attached to a redundant array of independent disks (RAID) controller that supports RAID levels 0, 1, 5, and 10. The write performance of the transaction log needs to be maximized. The database and transaction log files must be protected in the event of a drive failure. You need to design the storage system. Which storage configuration should you use?()A、A single RAID 5 volumeB、A single RAID 10 volumeC、A RAID 0 volume and a RAID 5 volumeD、A RAID 1 volume and a RAID 5 volume
单选题A customer has a file server with RAID-5 using 8KB random I/Os, with 67% reads and 33% writes. How should the disk controller cache be configured for optimal performance?()AUse write-back cacheBUse write-back cache with battery backupCUse write-through cache with disk caching enabledDUse write-through cache with disk caching disabled
单选题Which of the following would be the BEST configuration when using seven SCSI drives in order to have full fault tolerance?()A RAID 0+1B RAID 0C RAID 1D RAID 5
单选题A banking customer is confused about RAID protection. Which of the following are characteristic of RAID-6?()ADouble drive failure in an array and extremely high data fault toleranceBDouble drive failure in an array and more total storage capacity than RAID-5CExtremely high data fault tolerance and higher performance than RAID-5DHigher performance than RAID-5 and more total storage capacity than RAID-5
单选题A customer has a file server using RAID-5 with 8KB sequential write operations. How should the disk controller cache be configured for optimal performance and data integrity?()AUse write-back cache with battery backup enabledBUse write-through cache with battery backup enabledCUse read-back cache with battery backup enabledDUse read-through cache with battery backup enabled
单选题A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()AIncrease the memory on the server.BReconfigure drives to a RAID 0+1.CInstall a battery backed write cache module in the system.DInstruct the user to save to the local system instead of to the server.
单选题An administrator is required to maintain space for 750GB of user data. Which of the following is the BEST option available to the administrator?()ACreate a RAID 5 array using five 200GB disks.BCreate a JBOD using four 200GB disks.CCreate a RAID 1 array using six 200GB disks.DCreate a RAID 5 array using three 200GB disks.
单选题Which of the following RAID levels can withstand the simultaneous loss of two physical drives in an array?()A RAID 0B RAID 3C RAID 5D RAID 10
单选题Which of the following RAID levels can withstand the simultaneous loss of two physical drives in an array?()ARAID 0BRAID 3CRAID 5DRAID 10
单选题An administrator is required to maintain maximum redundancy for 1TB of accounting files. Which of the following is the BEST option available to the administrator?()ACreate a RAID 5 array using eight 300GB disks.BCreate a RAID 10 array using six 300GB disks.CCreate a RAID 5 array using ten 300GB disks.DCreate a RAID 10 array using eight 300GB disks.
单选题You administer a SQL Server 2008 instance. You plan to deploy a new database that has the following capacity requirements: 275 GB for the database data file; 50 GB for the transaction log file. The storage array has six 100-GB disk drives available for the database. The disks are attached to a redundant array of independent disks (RAID) controller that supports RAID levels 0, 1, 5, and 10. The write performance of the transaction log needs to be maximized. The database and transaction log files must be protected in the event of a drive failure. You need to design the storage system. Which storage configuration should you use?()AA single RAID 5 volumeBA single RAID 10 volumeCA RAID 0 volume and a RAID 5 volumeDA RAID 1 volume and a RAID 5 volume
单选题A new storage array must be configured for a database server. This array will store transaction logs that are always being written. Which of the following RAID solutions would provide fault tolerance and fast write operations without the use of parity? ()A RAID 0B RAID 3C RAID 6D RAID 10
单选题Which of the following can help prevent data loss on a RAID array in the event of a power failure?()AUsing a RAID mirrorBA battery backed write cacheCUsing RAID with parityDA battery backed read cache