单选题As an extinguishing agent,foam().Acouducts electricityBshould be directed at the base of the fireCis most effective on burning gases which are flowingDextinguishes by cooling oil fires blow ignition temperature

单选题
As an extinguishing agent,foam().
A

couducts electricity

B

should be directed at the base of the fire

C

is most effective on burning gases which are flowing

D

extinguishes by cooling oil fires blow ignition temperature


参考解析

解析: 暂无解析

相关考题:

One of the limitations of foam as an extinguishing agent is that foam ______.A.cannot be made with salt waterB.is heavier than oil and sinks below its surfaceC.is corrosive and a hazard to fire fightersD.conducts electricity

______, as the chemical extinguisher agent, should be used for an electric fire.A.dry chemical or foamB.foam or soda acidC.carbon dioxide or foamD.carbon dioxide or dry chemical

An extinguishing agent which effectively cools, dilutes combustible vapors, removes oxygen, and provides a heat and smoke screen is ______.A.carbon dioxideB.Halon 1301C.dry chemicalD.water fog

As an extinguishing agent, foam ______.A.conducts electricityB.should be directed at the base of the fireC.is most efffective on buring gases which are flowingD.extinguishes by cooling oil fires below ignition temperature

Generally, the first action in extinguishing an LFG fire caused by escaping gas is to ______.A.sweep flames away with water sprayB.shut off the leakC.use a chemical foam fire extinguisherD.call the local fire department

单选题A portable foam fire extinguisher is placed in operation by()Aturning it upside downBpressing the foam leverCsqueezing the grip handleDopening the hose valve

单选题Production of mechanical foam by a portable in-line foam proportioner().Aincreases the size of foam bubbles formedBincreases the rate of foam productionCimproves the extinguishing properties of foamDgives the nozzleman more freedom of movement,since it can be placed anywhere in the hose line

单选题Which extinguishing agent is recommended in the Chemical Data Guide for use on a carbon disulfide fire?()AAlcohol foamBDry chemicalCChemical foamDWater fog

单选题On a bulk chemical carrier,water should NOT be used as an extinguishing agent to fight a fire if the water may come into contact with the chemical called().Aacrylic acidBbenzeneColeumDvinyl toluene

单选题A class B fire is most successfully fought by().Apreventing oxygen from reaching the burning materialBcooling the burning material below its ignition temperatureCusing the extinguishing agent to make the burning material fire-resistantDusing the extinguishing agent to absorb the heat

单选题What is an advantage of using foam in fire fighting?()AIt is effective in controlling fire in flowing oil such as coming from a broken fuel lineBIt absorbs heat from materials that could cause reignitionCMost foams can be used jointly with dry chemical extinguishing agents to attack a fire by two methods of extinguishmentDOnce the surface is blanketed with foam and the fire is extinguished,no further foam is required

单选题Generally, the first action in extinguishing an LFG fire caused by escaping gas is to().Asweep flames away with water sprayBshut off the leakCuse a chemical foam fire extinguisherDcall t e local fire department

单选题Water is a very effective fire extinguishing agent because it()Awill remove all the toxic fumes from the airBhas the greatest cooling abilityCwill leave no harmful residueDcompletely removes combustible vapors from the air

单选题Which extinguishing agent is the best for use on electrical fires?()AFoamBCO2CDry chemicalDWater fog

单选题Which fire extinguishing agent can NOT be used on an ethylenediamine?()AWater foamBDry chemical powderCWater fogDAlcohol foam

单选题As an extinguishing agent,foam().Aconducts electricityBshould be directed at the base of the fireCis most effective on burning gases which are flowingDextinguishes by cooling oil fires below ignition temperature

单选题Which extinguishing agent will cool down a heated bulkhead in the least amount of time?()AWater streamBWater fog or aprayCSteamDDry chemical

单选题Which extinguishing agent is NOT recommended in the Chemical Data Guide for use on a cyclohexane fire?()AFoamBCarbon dioxideCDry chemicalDWater fog

单选题The best method of extinguishing a class A fire is to().Aremove oxygen from the areaBcool fuel below ignition temperatureCsmother with CO2Dsmother fire with foam

单选题A definite advantage of using water as a fire extinguishing agent is its characteristic of().Aalternate expansion and contraction as water in a liquid state becomes a vaporBabsorption of smoke and gases as water is converted from a liquid to a vaporCrapid contraction as water is converted from a liquid to a vaporDrapid expansion as water absorbs heat and changes to steam

单选题What is the most important characteristic of the extinguishing agent in fighting a class C fire?()AWeightBTemperatureCElectrical nonconductivityDCost

单选题Which of the following statements is true concerning Halon 1301 fire extinguishing equipment?()AThe agent is considered nontoxic at room temperature in low concentrationsBThe agent is less effective than carbon dioxideCHalon primarily extinguishes the fire by coolingDThe agent cannot be used on electrical fires because it leaves a residue

单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()ACarbon dioxide is corrosive when exposed to fireBCarbon dioxide should be applied slowly to a large engine room fireCIts total cooling effect is far greater than waterDIts smothering effect is excellent for class B fires

多选题On what conditions may an exemption certificate,exempting from the requirement to install a fixed fire extinguishing system in a cargo space,be issued?()AThe ship is constructed and solely intended for carriage of ore, coal, grain, unseasoned timber, non-combustible cargoes or cargoes which according to the Administration constitute a low fire riskBSteel hatch covers and effective means of closing all ventilators and other openings to the cargo space are fittedCA fixed deck foam system is be fitted in lieu of the cargo space extinguishing systemDThe vessel is less than 10 000 gross tonnage

单选题An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().Acarbon dioxideBHalon 1301Cdry chemicalDwater fog

单选题0ne of the limitations of foam as an extinguishing agent is that foam().Acannot be made with salt waterBis heavierthan oil and sinks below its surfaceCis corrosive and to fire fightersDconducts electricity

单选题Generally,the first action in extinguishing an LFG fire caused by escaping gas is to().Asweep flames away with water sprayBshut off the leakCuse a chemical foam fire extinguisherDcall the local fire department

单选题Where foam extinguishing systems are provided on a ship,each machinery flat in the protected space must have a(n)().AcoamingBalarmCdrainDfire sensor