单选题An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().Acarbon dioxideBHalon 1301Cdry chemicalDwater fog

单选题
An extinguishing agent which effectively cools,dilutes combustible vapors,removes oxygen,and provides a heat and smoke screen is().
A

carbon dioxide

B

Halon 1301

C

dry chemical

D

water fog


参考解析

解析: 暂无解析

相关考题:

One of the limitations of foam as an extinguishing agent is that foam ______.A.cannot be made with salt waterB.is heavier than oil and sinks below its surfaceC.is corrosive and a hazard to fire fightersD.conducts electricity

An extinguishing agent which effectively cools, dilutes combustible vapors, removes oxygen, and provides a heat and smoke screen is ______.A.carbon dioxideB.Halon 1301C.dry chemicalD.water fog

As an extinguishing agent, foam ______.A.conducts electricityB.should be directed at the base of the fireC.is most efffective on buring gases which are flowingD.extinguishes by cooling oil fires below ignition temperature

Foam is a very effective smothering agent and ______.A.it provides cooling as a secondary effectB.works well on extinguishing electrical firesC.can be used to combat combustible metal firesD.All of the above

Which agent will be selected when the Resource Selection Criteria is set to circular routing?()A、the agent who has been in the Available state for the longest amount of time  B、the next available agent with the highest priority, as determined by the agent order in the Resources listC、the next available agent, based on the last agent selected and the agent order in the Resources list  D、the agent assigned to the selected Resource Group and is thus qualified to be selected

Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

cindy has created a private agent. she wants her colleagues to be able to use it. which one of the following should she do to achieve this?()A、 change the agent property to shared B、 copy the agent to a domino 6 server C、 change the agent property to shared code D、 delete the agent. She must create it again as a shared agent

单选题Which extinguishing agent is recommended in the Chemical Data Guide for use on a carbon disulfide fire?()AAlcohol foamBDry chemicalCChemical foamDWater fog

单选题On a bulk chemical carrier,water should NOT be used as an extinguishing agent to fight a fire if the water may come into contact with the chemical called().Aacrylic acidBbenzeneColeumDvinyl toluene

单选题A class B fire is most successfully fought by().Apreventing oxygen from reaching the burning materialBcooling the burning material below its ignition temperatureCusing the extinguishing agent to make the burning material fire-resistantDusing the extinguishing agent to absorb the heat

单选题Which is a disadvantage of Halon as a fire extinguishing medium?()AConducts electricityBDifficult to storeCLarge volume necessary to be effectiveDIneffective in powdered metal fires

单选题For which of the listed classes of fire combinations would carbon dioxide be most suitable as the extinguishing agent ().AClass A and class BBClass B and class CCClass A and class CDClass C, class D, and class E

单选题Which agent will be selected when the Resource Selection Criteria is set to circular routing?()Athe agent who has been in the Available state for the longest amount of time  Bthe next available agent with the highest priority, as determined by the agent order in the Resources listCthe next available agent, based on the last agent selected and the agent order in the Resources list  Dthe agent assigned to the selected Resource Group and is thus qualified to be selected

单选题Water is a very effective fire extinguishing agent because it()Awill remove all the toxic fumes from the airBhas the greatest cooling abilityCwill leave no harmful residueDcompletely removes combustible vapors from the air

单选题Which extinguishing agent is best for use on a magnesium fire?()AWaterBSandCCO2DDry chemical

单选题Which extinguishing agent is the best for use on electrical fires?()AFoamBCO2CDry chemicalDWater fog

单选题As an extinguishing agent,foam().Aconducts electricityBshould be directed at the base of the fireCis most effective on burning gases which are flowingDextinguishes by cooling oil fires below ignition temperature

单选题Which extinguishing agent will cool down a heated bulkhead in the least amount of time?()AWater streamBWater fog or aprayCSteamDDry chemical

单选题Which extinguishing agent is NOT recommended in the Chemical Data Guide for use on a cyclohexane fire?()AFoamBCarbon dioxideCDry chemicalDWater fog

多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

单选题cindy has created a private agent. she wants her colleagues to be able to use it. which one of the following should she do to achieve this?()A change the agent property to shared B copy the agent to a domino 6 server C change the agent property to shared code D delete the agent. She must create it again as a shared agent

单选题What is the most important characteristic of the extinguishing agent in fighting a class C fire?()AWeightBTemperatureCElectrical nonconductivityDCost

单选题Which of the following statements is true concerning Halon 1301 fire extinguishing equipment?()AThe agent is considered nontoxic at room temperature in low concentrationsBThe agent is less effective than carbon dioxideCHalon primarily extinguishes the fire by coolingDThe agent cannot be used on electrical fires because it leaves a residue

单选题Which of the listed extinguishing agents is NOT suitable for fighting a liquid paint fire?()ADry chemicalBFoamCWaterDCarbon dioxide

单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()ACarbon dioxide is corrosive when exposed to fireBCarbon dioxide should be applied slowly to a large engine room fireCIts total cooling effect is far greater than waterDIts smothering effect is excellent for class B fires

单选题0ne of the limitations of foam as an extinguishing agent is that foam().Acannot be made with salt waterBis heavierthan oil and sinks below its surfaceCis corrosive and to fire fightersDconducts electricity

单选题Foam is a very effective smothering agent and().Ait provides cooling as a secondary effectBworks well on extinguishing electrical firesCcan be used to combat combustible metal firesDAll of the above