单选题A customer is experiencing problems with a failed disk drive on their newly purchased p630 server. The IBM CE has replaced the disk and now the mirrored Logical Volume needs to be re-created. The customer does not have the skills to do this. There is no support contract with the solution provider but the p630 is covered under a Software Maintenance Agreement (SWMA) 24/7 contract. What should the pSeries technical specialist do first?()AOffer to rebuild the logical volume for a fee.BOffer to talk the customer through the procedure to rebuild the logical volume for a fee.CSuggest the customer open a call with IBM TechLine; offer to explain how the process works.DSuggest the customer open a call with IBM SupportLine; offer to explain how the process works.
单选题
A customer is experiencing problems with a failed disk drive on their newly purchased p630 server. The IBM CE has replaced the disk and now the mirrored Logical Volume needs to be re-created. The customer does not have the skills to do this. There is no support contract with the solution provider but the p630 is covered under a Software Maintenance Agreement (SWMA) 24/7 contract. What should the pSeries technical specialist do first?()
A
Offer to rebuild the logical volume for a fee.
B
Offer to talk the customer through the procedure to rebuild the logical volume for a fee.
C
Suggest the customer open a call with IBM TechLine; offer to explain how the process works.
D
Suggest the customer open a call with IBM SupportLine; offer to explain how the process works.
参考解析
解析:
暂无解析
相关考题:
A customer receives a CD-RW disk from a computer vendor. The customer tries to read the disk in a computer with a 4X CD-ROM drive and is unable to read any information. The customer tries the CD-RW disk on a 32X CD-ROM drive and it reads correctly. What is the cause of this problem?()A、The 4X CD-ROM drive has dirty optics or laser and requires cleaning.B、The 4X CD-ROM drive needs to be jumpered to support CD-RW disks.C、The 4X CD-ROM drive does not support the multi-read specification.D、The 4X CD-ROM is fine, but the CD-RW disk has a flaw in its format.
A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive. Which of the following is the MOST likely cause of the failures?()A、 The backplane has failed and needs to be replaced.B、 The array must be disbanded and recreated from a backup source to recognize the replacement drive.C、 There is a conflict with the optical drive on the server.D、 The server power supply is failing and not providing enough power for all the drives.
An administrator has added a new hard drive to a server that is running out of space on its C Drive and is experiencing slow performance. The administrator needs to free up space on the C Drive.Which of the following is the BEST action for the administrator to take to free up space on the drive?()A、Move the page file to the new drive.B、Copy the system32 directory to the new drive.C、Convert the C drive to a basic disk.D、Setup a software RAID to mirror the C drive.
A disk drive failed in a RAID 5 array. After replacing the disk drive, users are still reporting that access to the server is very slow. Which of the following BEST explains the problem?()A、The array is rebuilding.B、The array must be reconfigured.C、The array is corrupt.D、The disk drive is not compatible.
A user reports that their hard drive has failed and needs to be replaced. Which of the following should the technician do FIRST?()A、Run the hard disk manufacturer’s diagnostic programB、Re-image the driveC、Replace the hard drive and load WindowsD、Ask the user diagnostic questions
Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()A、Use lquerypv to read the driveB、Use lspv and look at PP Size valueC、Look on the outside of the drive itselfD、Use bootinfo to find the LTG on the drive
A customer is experiencing problems with a failed disk drive on their newly purchased p630 server. The IBM CE has replaced the disk and now the mirrored Logical Volume needs to be re-created. The customer does not have the skills to do this. There is no support contract with the solution provider but the p630 is covered under a Software Maintenance Agreement (SWMA) 24/7 contract. What should the pSeries technical specialist do first?()A、Offer to rebuild the logical volume for a fee.B、Offer to talk the customer through the procedure to rebuild the logical volume for a fee.C、Suggest the customer open a call with IBM TechLine; offer to explain how the process works.D、Suggest the customer open a call with IBM SupportLine; offer to explain how the process works.
A customer indicates that a system is experiencing printing problems. After checking the system, and successfully printing, no problem has been found. Which of the following procedures should be performed next to further clarify the problem?()A、 Reboot the system.B、 Check the file system sizes.C、 Have the customer repeat the task to recreate the problem.D、 Inform the customer that no problems were found, and to call back if the problem reoccurs.
A customer is experiencing problems with a rack mount server. The problem might be a failing memory module. Which of the following can be used to find the failing module without going to the physical server?()A、Light Path DiagnosticsB、Remote PresenceC、Integrated Management Module (IMM)D、Advanced Management Module (AMM)
A customer with three Windows servers wants to create a shared storage array. One server runs a200 GB Oracle database with high transaction rates. The second server is a file server with 3 TBof data and the third server is a mail server with 150 GB of storage. The key customer decisionmaker has only purchased EMC CX storage products in his previous employment. Cost is a keyconsideration. From the following which is a key feature that could convince the customer topurchase a DS3500 over an EMC CX storage system?()A、 SATA and SAS 2.0 disk drive technology can be mixed in different enclosures B、 nearline SAS 2.0 and SAS 2.0 disk drive technology can be mixed in the same enclosureC、 SATA disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution D、 SAS 2.0 disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution
A customer has a storage requirement for a mixed IBM Power AIX and System z environment. They require approximately 3 TB of high performance disk for their System z environment. They require approximately 32 TB of low-performance disk for their System p environment. The storage specialist is using Capacity Magic to configure an IBM DS8700. Which configuration is most appropriate for this customer()A、2 x 300 GB 15k rpm disk drive sets for System z; and 4 x 2 TB 7.2k rpm disk drive sets for Power AIXB、4 x 146 GB 15k rpm disk drive sets for System z; and 4 x 2 TB 7.2k rpm disk drive sets for Power AIXC、2 x 300 GB 10k rpm disk drive sets for System z; and 4 x 300 GB 15k rpm disk drive sets for Power AIXD、2 x 300 GB 15k rpm disk drive sets for System z; and 2 x 1 TB 7.2k rpm disk drive sets for Power AIX
An administrator suspects problems on a SCSI hard disk, but upon running diagnostics, no errors were found. What must be done to check the condition of the drive?()A、Run diag and select the 'Certify Media' task.B、Perform a read and write test on the disk and monitor errorlog.C、Update the disk firmware to the latest level and monitor errorlog.D、Format the disk to ensure bad blocks are omitted from the disk layout.
You are the network administrator for your company. All network servers run Windows Server 2003. One of your servers contains a RAID-5 volume. Routine monitoring reveals a failed disk in the set. The server is running and users are connecting to shared folders on the RAID-5 volume. You shut down the server and replace the failed disk. Now you need to ensure that the RAID-5 volume is redundant. What should you do? ()A、Initialize the new disk. Select the failed region and then select the Repair Volume option.B、Import the foreign disk. Select the failed region and then select the Repair Volume option.C、Initialize the new disk. Select the failed region and then select the Reactivate Disk option.D、Import the foreign disk. Select the failed region and then select the Reactivate Disk option.
A customer is experiencing a performance bottleneck. The server is performing sequential I/O requests with large block sizes of 64KB. Improving which of the following storage subsystem characteristics has the biggest impact on this bottleneck?()A、Seek TimeB、Drive RPMC、Data Transfer RateD、Rotational Latency
单选题A customer receives a CD-RW disk from a computer vendor. The customer tries to read the disk in a computer with a 4X CD-ROM drive and is unable to read any information. The customer tries the CD-RW disk on a 32X CD-ROM drive and it reads correctly. What is the cause of this problem?()AThe 4X CD-ROM drive has dirty optics or laser and requires cleaning.BThe 4X CD-ROM drive needs to be jumpered to support CD-RW disks.CThe 4X CD-ROM drive does not support the multi-read specification.DThe 4X CD-ROM is fine, but the CD-RW disk has a flaw in its format.
单选题Which of the following is a benefit of ASM fast disk resync?()A Failed disks are taken offline immediately but are not dropped.B Disk data is never lost.C By default, the failed disk is not dropped from the disk group ever, protecting you from loss of that disk.D The failed disk is automatically reformatted and then resynchronized to speed up the recovery process.E Hot spare disks are automatically configured and added to the disk group.
单选题A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive. Which of the following is the MOST likely cause of the failures?()A The backplane has failed and needs to be replaced.B The array must be disbanded and recreated from a backup source to recognize the replacement drive.C There is a conflict with the optical drive on the server.D The server power supply is failing and not providing enough power for all the drives.
单选题A customer indicates that a system is experiencing printing problems. After checking the system, and successfully printing, no problem has been found. Which of the following procedures should be performed next to further clarify the problem?()A Reboot the system.B Check the file system sizes.C Have the customer repeat the task to recreate the problem.D Inform the customer that no problems were found, and to call back if the problem reoccurs.
单选题You are the network administrator for All network servers run Windows Server 2003. One of your servers, TestKingSrv1, contains a RAID-5 volume. Routine monitoring reveals a failed disk in the set. TestKingSrv1 is running and users are connecting to shared folders on the RAID-5 volume. You shut down the server and replace the failed disk. Now you need to ensure that the RAID-5 volume is redundant. What should you do?()AImport the foreign disk that is to replace the failed disk. Select the failed region and then select the Repair Volume option.BInitialize the new disk that is to replace the failed disk. Select the failed region and then select the Reactive Disk option.CInitialize the new disk that is to replace the failed disk. Select the failed region and then select the Repair Volume option.DImport the foreign disk that is to replace the failed disk. Select the failed region and then select the Reactive Disk option.
单选题A customer has an IBM System Storage Enterprise Storage Server and several EMC CX3 systems installed in a data center, attached to IBM System p servers. As a step toward data consolidation, they intend to put all data on a new DS8700. What would be the most important data migration factors to consider()Asector size and the amount of production dataBexisting RAID levels and the disk drive speedCsector size and existing RAID levelsDamount of production data and the disk drive speed
单选题A system administrator has a failed disk drive that is mirrored to another disk drive. They successfully removed the logical volume copies off of the failed disk drive. Which of the following commands should be used to remove the failed disk drive from the volume group?()AchvgBrmdevCreducevgDexportvg
单选题A disk drive failed in a RAID 5 array. After replacing the disk drive, users are still reporting that access to the server is very slow. Which of the following BEST explains the problem?()AThe array is rebuilding.BThe array must be reconfigured.CThe array is corrupt.DThe disk drive is not compatible.
单选题A customer needs 2 TB of high availability storage for eBusiness applications. Their servers arecurrently connected to two EMC Symmetrix subsystems that are running RAID 1. They want toconsolidate all of the RAID 1 storage into an IBM System Storage DS6800. Which configurationsatisfies these capacity requirements?()ATwo disk drive sets of 300 GB drivesBFour disk drive sets of 146 GB drivesCEight disk drive sets of 73 GB drivesDNine disk drive sets of 146 GB drives