单选题A datacenter manager would like to ensure that all fire suppression in the datacenter is safe for the equipment in the room. Which of the following classifications should be listed on the fire suppression system?()AABBCCDD
单选题
A datacenter manager would like to ensure that all fire suppression in the datacenter is safe for the equipment in the room. Which of the following classifications should be listed on the fire suppression system?()
A
A
B
B
C
C
D
D
参考解析
解析:
暂无解析
相关考题:
You would like to configure a fractional T1 interface on a channelized T3 controller with the following properties:Which set of configuration commands accomplishes this goal?() A.AB.BC.CD.D
You would like to configure a channelized OC3 interface with the following properties:Which set of configuration commands accomplishes this goal?() A.AB.BC.CD.D
You would like to configure an Ethernet interface with the following characteristics:Which set of configuration commands accurately completes this task?() A.AB.BC.CD.D
Which of the following is the MOST important physical consideration when deploying a new server?() A. Humidity monitors, Biometrics, and fire suppressionB. Cooling, rack space, and power requirementsC. Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD. Biometrics, fire suppression, and power requirements
A fire involving trash and paper waste would be classified as a ______.A.class AB.class BC.class CD.class D
A fire in a pile of canvas would be classified as a ______.A.class AB.class BC.class CD.class D
Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
A datacenter manager would like to ensure that all fire suppression in the datacenter is safe for the equipment in the room. Which of the following classifications should be listed on the fire suppression system?()A、AB、BC、CD、D
Lightening causes a power surge and leads to a fire in the datacenter. Following emergency procedures, which of the following is the FIRST thing the server administrator should do?()A、Turn off all electrical powerB、Remove all backup mediaC、Implement fire suppressionD、Evacuate all personnel
Which of the following is the MOST important physical consideration when deploying a new server?()A、 Humidity monitors, Biometrics, and fire suppressionB、 Cooling, rack space, and power requirements冷C、 Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD、 Biometrics, fire suppression, and power requirements
Which of the following is the MOST important physical consideration when deploying a new server?()A、Humidity monitors, Biometrics, and fire suppressionB、Cooling, rack space, and power requirementsC、Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD、Biometrics, fire suppression, and power requirements
The server room that an administrator manages has just caught fire. Which of the following is the FIRST thing that the administrator should do?()A、 Evacuate all personnel.B、 Notify staff of the potential service outage.C、 Use fire suppression techniques until the fire department arrives.D、 Grab the backup tapes and exit the server room.
单选题Which of the listed classes of fire is considered as one involving electrical equipment?()AClass ABClass BCClass CDClass D
单选题Which of the actions listed should be taken FIRST to control an oil fire in a fuel oil tank?()ACommence draining that tank as quickly as possibleBSeal off all vents to that tankCActivate the CO2 system to that tankDShut off the steam heating coils
单选题You would like to configure a fractional T1 interface on a channelized T3 controller with the following properties: Which set of configuration commands accomplishes this goal?()A AB BC CD D
单选题Fire protection regulations for towing vessels require all crew members to know how to perform each of these tasks EXCEPT().Astart the mechanical ventilation system for the engine roomBoperate the fuel shut-off for the engine roomCoperate all fire extinguishing equipment aboard the vessel on board the vessel,including starting the fire pumpDAll of the above
单选题Which of the following is the MOST important physical consideration when deploying a new server?()A Humidity monitors, Biometrics, and fire suppressionB Cooling, rack space, and power requirements冷C Service level agreements, uninterruptible power supply (UPS) deployment, and CCTVD Biometrics, fire suppression, and power requirements
单选题Lightening causes a power surge and leads to a fire in the datacenter. Following emergency procedures, which of the following is the FIRST thing the server administrator should do?()ATurn off all electrical powerBRemove all backup mediaCImplement fire suppressionDEvacuate all personnel
单选题If ignited, which of the listed materials would be a class "B" fire?()AMagnesiumBPaperCWoodDDiesel Oil
单选题When the PSCO would like to witness a fire drill carried out by the crew, he should consult ()to locate a simulated fire.Athe manager of the companyBthe surveyor of the Classification SocietyCthe master of the vesselDthe chief engineer of the vessel
多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
单选题The server room that an administrator manages has just caught fire. Which of the following is the FIRST thing that the administrator should do?()A Evacuate all personnel.B Notify staff of the potential service outage.C Use fire suppression techniques until the fire department arrives.D Grab the backup tapes and exit the server room.
单选题The server room that an administrator manages has just caught fire. Which of the following is the FIRST thing that the administrator should do?()AEvacuate all personnel.BNotify staff of the potential service outage.CUse fire suppression techniques until the fire department arrives.DGrab the backup tapes and exit the server room.
单选题Which of the actions listed should be taken by the engineer on watch when the general alarm is sounded continuously for 10 seconds?()AEngine room ventilation should be startedBMain engines should be securedCThe fire pump should be startedDThe fixed CO2 system should be activated
单选题Which of the listed materials would be considered as a bunting class "C" fire?()AFuel oilBWoodCCelluloidDElectrical insulation
单选题Which of the following is the MOST important physical consideration when deploying a new server?()AHumidity monitors, Biometrics, and fire suppressionBCooling, rack space, and power requirementsCService level agreements, uninterruptible power supply (UPS) deployment, and CCTVDBiometrics, fire suppression, and power requirements
单选题If a CO2 fire extinguisher is not readily available, which of the listed fire extinguishers would be best suited to combat a small electrical fire in a switchboard?()ADry chemicalBHalonCLow velocity fogDSteam