单选题Excessively warm water leaving condenser may be caused by()Afouled tubes in shell and tube condenserBtoo little or too warm condenser waterCair or non-condensable gas in systemDovercharge of refrigerant
单选题
Excessively warm water leaving condenser may be caused by()
A
fouled tubes in shell and tube condenser
B
too little or too warm condenser water
C
air or non-condensable gas in system
D
overcharge of refrigerant
参考解析
解析:
暂无解析
相关考题:
When you go shopping and want to buy some clothes,you should think about which kind of clothes you really need and decide how_____money you can _____on them. Then look at the labels that are inside the new clothes. They tell you how to _____the clothes. The label for a shirt may tell you to wash it in warm water. A sweater label may tell you to wash it in cold water. The label on a coat may say “dry clean only” and cleaning in water may _____this coat. If you do _____the directions say on the label, you can keep your clothes looking their best.1.A. muchB. manyC. large2.A. costB. spendC. take3.A. take place ofB. take use ofC. take care of4.A. changeB. replaceC. ruin5.A. asB. byC. for
If a refrigeration compressor is short cycling on high head pressure, you shouldA.purge the condenser if the waterside is dirtyB.check for proper water flow through the condenserC.increase the high pressure cutout settingD.reduce the cooling water flow
Low compressor head pressure in a refrigeration system can be caused by ___.A.insufficient condenser cooling waterB.excessive condenser cooling waterC.air in the refrigeration systemD.excessive refrigerant in the system
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?A.A shortage of liquid refrigerant.B.Excessive frost on the evaporator.C.Excessive condenser cooling water.D.Insufficient condenser cooling water flow.
Persons who have swallowed a non-petroleum based poison are given large quantities of warm soapy water or warm salt water to ______.A.induce vomitingB.absorb the poison from the bloodC.neutralize the poison in the bloodD.increase the digestive process and eliminate the poison
What represents poor sanitary procedures ________.A.Keep and use a separate filling hose for potable(drinking)waterB.Locate potable(drinking)water tanks as low as possible in the bilgeC.Eliminate enclosed spaces in which trash,food particles,dirt may gatherD.After washing dishes with soap and warm water,sterilize them in water of at least 170℉(76.7℃)
A frontal thunderstorm is caused by ______.A.pronounced local heatingB.wind being pushed up a mountainC.a warm air mass rising over a cold air massD.an increased lapse rate caused by advection of warm surface air
单选题Low compressor head pressure in a refrigeration system can be caused by().Ainsufficient condenser cooling waterBexcessive condenser cooling waterCair in the refrigeration systemDexcessive refrigerant in the system
单选题Black smoke coming from a boiler can be caused by ().Alow water levelBhigh water levelCexcessively high fuel pressureDlow oil temperature
单选题A water pump can not supply water after startingIt may be caused by ().Aclosed discharge valveBbroken pipe lineCworn shaftDboth A and B
单选题In the condenser, the hot, high pressure refrigerant gas is cooled by the sea water and becomes().Afresh waterBvaporCmixtureDliquid
单选题If a refrigeration compressor is short cycling on high head pressure, you should ().Apurge the condenser if the waterside is dirtyBcheck for proper water flow through the condenserCincrease the high pressure cutout settingDreduce the cooling water flow
单选题If the high-pressure switch on the compressor opens and stops the compressor a possible cause could be:()Atoo much cooling water going through the condenserBnot enough refrigerant in the systemCa leak in the evaporator coilsDno enough cooling water going through the condenser
单选题Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?()AA shortage of liquid refrigerantBExcessive frost on the evaporatorCExcessive condenser cooling waterDInsufficient condenser cooling water flow
单选题A frontal thunderstorm is caused by().Apronounced local heatingBwind being pushed up a mountainCa warm air mass rising over a cold air massDan increased lapse rate caused by advection of warm surface air
单选题If the temperature in the icebox is too high, the trouble could be()Aa clogged scale trapBair in the systemCautomatic controls not functioning properlyDinsufficient cooling water to the condenser
单选题Electrical failures in motors are caused by the breakdown of insulation, which may be caused by ()Apenetration of moistureBaccumulation of dirtCoverheatingDAll of the above
单选题Fighting a rig fire in the ballast pumproom with hoses would adversely affect the stability of the rig most by().Aincreasing the permeability of the pumproomBreduction of drill water from the storage tanksCa list caused by water filling the compartmentDa reduced KG caused by water filling the compartment
单选题In the two stage flash distilling plant, which of the pumps listed is vented to the shell of the second stage in order to remove vapor from the pump suction?()ACondenser circulating water pumpBFeed-water heater drain pumpCDistillate pumpDAir ejector condenser drain pump
单选题In a diesel engine cooling system, the high temperature alarm contact maker will be activated on excessively high water discharge temperature from the ()Araw water pump dischargeBexpansion tank outletCcooling water heat exchangerDoutlet engine jacket water outlet
单选题The reciprocating pump can’t draw water from a tank may be caused by ().Aleaky pipeBopened inlet valveCtoo much water in tankDNone of the above
单选题Early models of the flash-type evaporators used a separate shell-and-tube heat exchanger as the air ejector condenser.More recent models use a combined air ejector condenser with the()Adistilling condenserBsalt water feed heaterCdistillate coolerDflash chamber
单选题Persons who have swallowed a non-petroleum based poison are given large quantities of warm soapy water or warm salt water to ()Ainduce vomitingBabsorb the poison from the bloodCneutralize the poison in the bloodDincrease the digestive process and eliminate the poison
单选题While troubleshooting a refrigeration system for low head pressure, liquid refrigerant flooding back from the evaporator is determined to be the causeIt may be necessary to ().Achange the expansion valve adjustmentBreadjust the water regulating valve to increase the flow of waterCpurge air from the condenserDclean the waterside of the condenser
单选题In a refrigeration system, if the cooling water to the condenser fails, the().Abox temperature solenoid valve will closeBexpansion valve will closeCcompressor will shutdownDking valve will open
单选题Which of the following may cause that excessively warm water leaves the condenser in a refrigeration plant? () (1) too little cooling water (2) too much cooling water (3) too warm cooler waterA(1)onlyBanyof(1),(2)and(3)Canyof(1)and(3)Danyof(1)and(2)
单选题Which statement concerning the collection of fresh water is FALSE?()AFresh water may be obtained from fishBLifeboat covers or canopies should be washed with rain before drinking water is collectedCFresh water may be collected from condensation inside the liferaftDSeawater should never be consumed