单选题Companycom is purchasing a p5 595 as part of a large server consolidation. They are planning on using micropartitioning and Virtual IO to consolidate small machines. They used the rPerf numbers for AIX 5.3 to size their solutions. They discovered that their application is not yet certified on AIX 5.3, so they will have to use AIX 5.2. What changes should be made to their configuration?()AIncrease memoryBAdd more adaptersCIncrease both processors and adaptersDIncrease the number of processors by 20 - 30%

单选题
Companycom is purchasing a p5 595 as part of a large server consolidation. They are planning on using micropartitioning and Virtual IO to consolidate small machines. They used the rPerf numbers for AIX 5.3 to size their solutions. They discovered that their application is not yet certified on AIX 5.3, so they will have to use AIX 5.2. What changes should be made to their configuration?()
A

Increase memory

B

Add more adapters

C

Increase both processors and adapters

D

Increase the number of processors by 20 - 30%


参考解析

解析: 暂无解析

相关考题:

Companycom has a p5 595 with no DVD configured on this server. How can they install the Virtual IO Server code?()A、From the HMCB、From a NFS mountC、From a FTP serverD、From any CD or DVD drive on another server

Companycom has a requirement to consolidate six web application servers. There is unused capacity of 2 CPUs on their new p5 570. Which operating systems and or features are required?()A、APV, AIX5.2ML4B、AIX5.3 or i5/OSC、APV, i5/OS, AIX5.3D、APV, AIX5.3 or SuSE9

Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()A、Create two virtual adapters on the client, each one from a separate Virtual IO ServerB、Enable dead gateway detection on the client so that the network traffic can be reroutedC、Have a spare network card on standby in the client in case the Virtual IO Server goes downD、Create an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

Companycom is purchasing a p5 595 as part of a large server consolidation. They are planning on using micropartitioning and Virtual IO to consolidate small machines. They used the rPerf numbers for AIX 5.3 to size their solutions. They discovered that their application is not yet certified on AIX 5.3, so they will have to use AIX 5.2. What changes should be made to their configuration?()A、Increase memoryB、Add more adaptersC、Increase both processors and adaptersD、Increase the number of processors by 20 - 30%

Companycom is migrating from a p690 to a p5 595 utilizing APV Virtual IO features. They have created their profiles for their two Virtual IO Servers. The first Virtual IO Server is installed and running. When trying to DLPAR the DVD/ROM the task fails on the HMC. What is the probable cause?()A、APV key is not registeredB、Networking and DNS are not configuredC、/etc/hosts table on HMC is not configuredD、Virtual IO Server dose not support DLPAR

Companycom is migrating from p670 systems running AIX 5.2 to p5 595 systems running AIX 5.3. They will be changing out only the system units. They will re-use the existing 61D drawers and adapters with the new p5 595 systems. What compatibility issue must be considered?() A、APV features are not supported for some legacy POWER4 adaptersB、APV will require the most current maintenance level for AIX 5.2C、APV features will require that legacy POWER4 adapters be updated with new microcodeD、The Virtual IO Server must run AIX 5.3 and the LPARs can run either AIX 5.2 or AIX 5.3

A customer wants to take advantage of IBM’s Micro-Partitioning capabilities for their new AIX applications.   The pSeries technical specialist should recommend purchasing which of the following?()A、p5 hardware, AIX 5.2, Virtual I/O ServerB、POWER4 hardware, AIX 5.3, Virtual I/O Server,C、p5 hardware, AIX 5.3, Advanced POWER Virtualization featureD、POWER4 hardware, AIX 5.2, Advanced POWER Virtualization feature

Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()A、Upgrade the p690 to a p5 590 server running AIX 5.3B、Upgrade the p690 server to AIX 5.3 and implement Advanced Power VirtualizationC、Purchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adaptersD、Purchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()A、VIO ServerB、AIX 5.2 ML4C、Shared Ethernet AdapterD、AIX 5.3 with Advanced Power Virtualization

Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()A、Apply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. B、Purchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. C、Verify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. D、Verify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.

Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()A、Reallocate the Virtual IO Server disks to the user LPARB、Create a stripe-group within the Virtual IO Server to protect against disk failureC、Reconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskD、Create a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

Companycom is planning for a 64-way p5 595. The plan is to use Virtual IO Servers and micropartitioning. What is the maximum number of partitions they can allocate?()A、128B、254C、320D、640

Companycom has a requirement for an LPAR in their p5 595 to run SUSE Linux. They also require an adapter that is not currently supported in Linux. Which of the following would be the best solution to recommend?()A、Assign the adapter to an IO Hosting partitionB、Use AIX 5L affinity to move the application from SUSE to AIXC、Use AIX 5.3 drivers to install the adapter in the Linux LPARD、Assign the adapter to an AIX 5.3 partition running Linux Affinity

Companycom wants to buy a new p5 570 running AIX 5.3. The applications require 4 processors and 8GB of memory. There is a requirement to have a Virtual IO Server. What is the smallest p5 570 that should be sold to this customer?()A、4 processors 8GB of memoryB、5 processors 8GB of memoryC、4 processors 10GB of memoryD、5 processors 10GB of memory

单选题Companycom LPAR that is using a Virtual IO Server needs to be more highly available. How can this be accomplished using APV features?()AReallocate the Virtual IO Server disks to the user LPARBCreate a stripe-group within the Virtual IO Server to protect against disk failureCReconfigure the user LPAR to use both locally owned disk and a Virtual SCSI diskDCreate a second Virtual IO Server and reconfigure the user LPAR to mirror across both Virtual IO Servers

单选题Companycom has a requirement to consolidate six web application servers. There is unused capacity of 2 CPUs on their new p5 570. Which operating systems and or features are required?()AAPV, AIX5.2ML4BAIX5.3 or i5/OSCAPV, i5/OS, AIX5.3DAPV, AIX5.3 or SuSE9

单选题A large customer is consolidating their pSeries systems onto a p5 590. They will have a requirement for a single device (disk, lun) to have multiple paths through different  adapters in a single LPAR. The primary applications were written for AIX 5.2. Which of the following would be the recommended solution to satisfy this requirement?()AAssign the adapters to a Virtual IO partitionBUse the MPIO function included in AIX 5.2CMigrate the application to AIX 5.3 and use the MPIO functionDSet up two Virtual IO partitions and attach both partitions to the device

单选题Companycom has successfully established their p5 LPAR environment on a POWER5 p5 590 running AIX 5.2. They are now ready to move to Virtual IO. What would be required to do Virtual IO?()AApply APAR IY62262 to the current AIX 5.2 Maintenance level 04. Virtual IO Server is not required. BPurchase Advanced POWER Virtualization software, upgrade to AIX 5.3 maintenance level 1 and apply APAR IY60349. Virtual IO Server is not required. CVerify that there are enough resources to add a Virtual IO Server, upgrade to AIX 5.3 with APAR IY60349, create a Virtual IO Server after applying APAR IY62262. DVerify that there are enough resources to add a Virtual IO Server, create a Virtual IO Server and apply APAR IY62262, verify that the system is at AIX 5.2 with Maintenance level 04.

单选题Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()AShared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.BVirtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.CShared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.DVirtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

单选题Companycom has a p5 595 with no DVD configured on this server. How can they install the Virtual IO Server code?()AFrom the HMCBFrom a NFS mountCFrom a FTP serverDFrom any CD or DVD drive on another server

单选题Companycom is migrating from p670 systems running AIX 5.2 to p5 595 systems running AIX 5.3. They will be changing out only the system units. They will re-use the existing 61D drawers and adapters with the new p5 595 systems. What compatibility issue must be considered?()AAPV features are not supported for some legacy POWER4 adaptersBAPV will require the most current maintenance level for AIX 5.2CAPV features will require that legacy POWER4 adapters be updated with new microcodeDThe Virtual IO Server must run AIX 5.3 and the LPARs can run either AIX 5.2 or AIX 5.3

单选题Companycom is migrating from a p690 to a p5 595 utilizing APV Virtual IO features. They have created their profiles for their two Virtual IO Servers. The first Virtual IO Server is installed and running. When trying to DLPAR the DVD/ROM the task fails on the HMC. What is the probable cause?()AAPV key is not registeredBNetworking and DNS are not configuredC/etc/hosts table on HMC is not configuredDVirtual IO Server dose not support DLPAR

单选题Companycom has a requirement for an LPAR in their p5 595 to run SUSE Linux. They also require an adapter that is not currently supported in Linux. Which of the following would be the best solution to recommend?()AAssign the adapter to an IO Hosting partitionBUse AIX 5L affinity to move the application from SUSE to AIXCUse AIX 5.3 drivers to install the adapter in the Linux LPARDAssign the adapter to an AIX 5.3 partition running Linux Affinity

单选题Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()AUpgrade the p690 to a p5 590 server running AIX 5.3BUpgrade the p690 server to AIX 5.3 and implement Advanced Power VirtualizationCPurchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adaptersDPurchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

单选题Companycom is planning for a 64-way p5 595. The plan is to use Virtual IO Servers and micropartitioning. What is the maximum number of partitions they can allocate?()A128B254C320D640

单选题Companycom will be using Virtual IO Server to share Ethernet adapters. What can be done to prevent network failure of the client if a Virtual IO Server goes down?()ACreate two virtual adapters on the client, each one from a separate Virtual IO ServerBEnable dead gateway detection on the client so that the network traffic can be reroutedCHave a spare network card on standby in the client in case the Virtual IO Server goes downDCreate an etherchannel adapter on the client using one Virtual Ethernet adapter from two separate Virtual IO Servers

单选题Companycom wants to buy a new p5 570 running AIX 5.3. The applications require 4 processors and 8GB of memory. There is a requirement to have a Virtual IO Server. What is the smallest p5 570 that should be sold to this customer?()A4 processors 8GB of memoryB5 processors 8GB of memoryC4 processors 10GB of memoryD5 processors 10GB of memory