单选题The cooling water jacket is common to all the cylinders but there are often () to ensure that each cylinder receives the right amount and flow of water.Adividing wallsBdivided wallsCdividing linersDdivided jackets

单选题
The cooling water jacket is common to all the cylinders but there are often () to ensure that each cylinder receives the right amount and flow of water.
A

dividing walls

B

divided walls

C

dividing liners

D

divided jackets


参考解析

解析: 暂无解析

相关考题:

What is head tank in the closed cooling water system used for?A.for the release of air from the cooling waterB.providing expansion room for heated cooling waterC.a place for implementing water and water treatment agentD.all of the above

The space between cylinder liner and jacket is called _____.A.the cooling waterB.the circulating waterC.the coolerD.the cooling water space

The cooling liquid used for the cylinder may be referred to as _____.A.jacket waterB.make-up waterC.boiler waterD.flushing water

Piston cooling fins are locatedA.atop the piston crownB.beneath the piston crownC.at the base of the piston skirtD.inside the cylinder liner cooling water jacket

Indirect cooling of fuel injector nozzle holders for diesel engines is accomplished primarily byA.heat conduction into the injected fuel oilB.heat conduction into the water jacket wallC.water circulation through passages in the holderD.fuel oil circulation through passages m the holder

Why is it necessary to have routine testing of the cooling water?A.To ensure that the proper residuals of treatment chemicals, as specified, are maintained all timeB.To trace leakage in the cooling water systemC.It is not necessaryD.To detect the presence of contaminants in the water that may be injurious to the cooling system

The most serious effect of air trapped in a diesel engine jacket water cooling system is that it ______.A.Causes colloid suspension in the cooling waterB.Reduces the capability of the lubrication systemC.Can form pockets which block the flow of coolant through the systemD.Leads to the scuffing of cylinder walls

单选题If a diesel engine were running at 20% overload with a smoky exhaust, you should()Astop the engine immediately to prevent damageBincrease lube oil pressureCslow the engine allowing it to gradually coolDdecrease the cooling water it temperature to the water jacket

单选题Which of the diesel engine cylinder liners listed has internal cooling water passages?()AInternally finned linerBExternally finned linerCWet linerDIntegral water-jacket liner

单选题If the operating element of a thermostatic valve installed in a diesel engine cooling system malfunctions, it may result in ()Aa low level in the engine expansion tankBexcessively high coolant pressureCimproper temperaturesDmalfunctioning of the jacket water heater

单选题If the jacket water temperature in an auxiliary diesel engine cooling system is lower than normal, the probable cause is ()Aair binding of the engine cooling systemBa cracked water cooled exhaust manifoldCblockage in the heat exchangerDfaulty operation of the thermostat

单选题The most serious effect of air trapped in a diesel engine jacket water cooling system is that it().Acauses colloid suspension in the cooling waterBreduces the capability of the lubrication systemCcan form pockets which block the flow of coolant through the systemDleads to the scuffing of cylinder walls

单选题The most common cause of lowering the crankcase lube oil flash point is ().Amore water contentsBcontamination with fuel oilChigher temperatureDsufficient cooling of oil mist

单选题Higher than normal jacket water temperatures occurring in all cylinders of a diesel engine can result from a/an ().Aoil suction line restrictionBcorrect amount of coolantCcavitation erosion in the water jacketsDclogged sea suction strainer

单选题Immediately after starting a diesel engine, normal raw water and jacket water pressure are indicatedHowever, the jacket water temperature continues to rise, if there is no change in the sea temperature, you should suspect()Aoverloading in all cylindersBa jammed three-way thermostatic valveCchromate PH too lowDa high level in the surge tank

单选题The outlet from an expansion tank of a closed freshwater cooling system should be piped to the ().Acylinder head water outlet headerBcylinder jacket inlet mainCheat exchanger inlet connectionDjacket water pump suction line

单选题The space between cylinder liner and jacket is called ().Athe circulating tankBthe scavenge boxCthe cooling water spaceDthe cooler

单选题In a diesel engine cooling system, the high temperature alarm contact maker will be activated on excessively high water discharge temperature from the ()Araw water pump dischargeBexpansion tank outletCcooling water heat exchangerDoutlet engine jacket water outlet

单选题Which of the following statements is correct concerning diesel engine cooling water systems?()AEach engine must have its own engine driven cooling water pump capable of providing cooling for all ranges of operationBpropulsion engines with bores exceeding 200 mm are to be fitted with a means to display the cooling water temperature of each cylinderCAt least two independent sea suctions are to be provided for supplying water to the engine jackets or to the heat exchangersDSuitable strain are to be fitted between the circulating pumps and heat exchangers when sea water is used for direct cooling

单选题In a diesel engine jacket water cooler, with seawater cooling the fresh water, the()Asea water temperature must never be warmer than 40℃Bjacket water pressure should always be greater than the sea water pressureCjacket water temperature must always be less than 60℃Djacket water pressure must always be less than the sea water pressure

单选题Indirect cooling of fuel injector nozzle holders for diesel engines is accomplished primarily by ().Aheat conduction into the injected fuel oilBheat conduction into the water jacket wallCwater circulation through passages in the holderDfuel oil circulation through passages in the holder

单选题Temperature control valves installed in the jacket cooling water system of a diesel engine modulates the rate of water flow through the ().Acooling water pumpBnozzle cooling passagesCcylinder jacketsDheat exchanger

单选题Which of the following statements is correct for the design and installation of diesel engine cooling water systems?()AAn alarm device with audible and visible signals is required for all cooling water systemsBPropulsion engines with bores over 200 mm are to be fitted with cooling water jacketsCEach totally enclosed cooling system shall be provided with a suitable head tankDDrain cocks are to be provided at the lowest points of all cylinder water jackets

单选题In more recent years, () heat exchangers have frequently been employed for jacket water and oil cooling.Ashell and tube typeBplate typeCcoil typeDconical disc type

单选题Some diesel engines are fitted with a thermometer in the cooling water outlet from each cylinderIf the cooling water temperature from all cylinders begins to rise above normal, you should suspect ()Aincrease blow-by in all cylindersBincomplete combustion in all cylinderCoverloading in all cylindersDinsufficient fuel delivery to all cylinders

单选题Which of the following conditions will develop if the flow of ‘raw’ cooling water to diesel engine is obstructed?()AAir will enter the cooling systemBCarbon will plug the water cooled exhaust manifoldsCThe jacket water temperature will riseDThe lube oil viscosity will increase

单选题Piston cooling fins are located()Aatop the piston crownBbeneath the piston crownCat the base of the piston skirtDinside the cylinder liner cooling water jacket