单选题The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()Acheck the output of the vmstat command on AIXBcheck the performance reports via TotalStorage Productivity Center for DataCcheck the performance reports via TotalStorage Productivity Center for DiskDcheck the improvement through the TotalStorage Expert report

单选题
The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()
A

check the output of the vmstat command on AIX

B

check the performance reports via TotalStorage Productivity Center for Data

C

check the performance reports via TotalStorage Productivity Center for Disk

D

check the improvement through the TotalStorage Expert report


参考解析

解析: 暂无解析

相关考题:

Which of the following tools can be used to configure the IBM System Storage DS8000? () A. IBM Systems DirectorB. Unisphere Management SuiteC. IBM System Storage Productivity Center (SSPC)D. IBM Standalone Solutions Configuration Tool (SSCT)

The Business Partner technical specialist is called to check if the addition of host ports on an IBM System Storage DS8000 system has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A、check the output of the vmstat command on AIXB、check the performance reports via TotalStorage Productivity Center for DataC、check the performance reports via TotalStorage Productivity Center for DiskD、check the improvement through the TotalStorage Expert report

Which of the following tools can be used to configure the IBM System Storage DS8000? ()A、IBM Systems DirectorB、Unisphere Management SuiteC、IBM System Storage Productivity Center (SSPC)D、IBM Standalone Solutions Configuration Tool (SSCT)

A customer using an IBM System Storage DS8300 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()A、using the "vmstat" command on the AIX servers connected via SAN to the DS8300 systemB、looking at the number of I/O managed by the DS8300 systemC、reading the performance reports via TotalStorage Productivity Center for DiskD、generating reports using the TotalStorage Expert

The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()A、check the output of the "vmstat" command on LINUXB、check the performance reports via Tivoli Storage Productivity Center for DataC、check the performance reports via Tivoli Storage Productivity Center for DiskD、check the output of the "iostat" command on AIX

An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()A、IBM System Storage DS8000: Host Systems Attachment GuideB、DS8000 Interoperability MatrixC、IBM System Storage DS8000: Introduction and Planning GuideD、IBM System Storage Solution Handbook

A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()A、perform a Disk Magic study B、review eConfig with a technical specialist C、confirm that the customer has enough ports available in the SAN infrastructure D、submit configuration to IBM System Storage Interoperability Center for validation

Which operating system can directly host managed storage for IBM i, AIX, Linux, VMware and Windows on a Power Systems server?()A、AIXB、IBM iC、LinuxD、VIO Server

A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()A、Competeline B、Executive Briefing Center C、Competitive Benchmark Center D、Field Technical Support Specialist (FTSS)

A customer asks for the thermal load (BTU/hr) to determine whether their existing cooling system will support the IBM System Storage DS8000.  Where can the sales representative find this information()A、IBM System Storage DS8000: Introduction and Planning GuideB、IBM DS8000 Interoperability Matrix on the support page on the webC、IBM System Storage DS8000: User’s GuideD、IBM System Storage DS8000: Solution Assurance Guide

A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()A、the IBM System Storage DS8000 Interoperability MatrixB、the IBM System Storage DS8000 Introduction and Planning GuideC、the IBM System Storage DS8000 Host System Attachment GuideD、the IBM System Storage DS8000 User’s Guide

A customer has an IBM System Storage DS8100 with 128 DDMs and needs to add additional capacity.  What must be verified by the Business Partner during the visit to the computer room()A、the space for the upgrade to a DS8700B、the space on the left of the DS8000 for an expansion frameC、the space on the right of the DS8000 for an expansion frameD、the space to install additional DDMs in the base frame

A customer wants to purchase an IBM System Storage DS8000. The proposed location is in a data center on the third floor of an office building.  Which document should the storage specialist consult to ensure that the DS8000 can be installed in the proposed location()A、IBM Announcement LettersB、IBM DS8000 Installation GuideC、IBM DS8000 Introduction and Planning GuideD、IBM Systems Storage Solutions Handbook

Select the IBM resource designed for small-to-medium business segments that helps identify System x server and storage for customers’ specific needs:()A、IBM System Advisor ToolB、IBM System x and BladeCenter Business Partner GuidebookC、Standalone Solutions Configuration Tool (SSCT)D、Configuration  Options Guide (COG)

An IBM Business Partner sells an IBM System Storage DS8700 to a customer.  Who is responsible for the installation and set up of the storage server()A、purchasing customerB、IBM Installation Readiness TeamC、IBM Customer EngineerD、IBM Business Partner

A company is consolidating four IBM System x servers. Each server has 500 GB of disk storage and each will grow to 2 TB within the next year. Additionally, the company will implement a SAN over the next year and must include connectivity and storage for its existing IBM System z and two IBM System p servers.    Which storage solution meets the company requirements()A、IBM System Storage DS3400B、IBM System Storage DS8100C、IBM System Storage N series N7800D、IBM System Storage DS4700

A customer using an IBM System Storage DS8700 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()A、using the "vmstat" command on the AIX servers connected via SAN to the DS8700 systemB、look at the IOPS using the DS8700C、reading the performance reports via Tivoli Storage Productivity Center for DiskD、generating reports using theTotalStorage Expert

单选题A Business Partner storage specialist is proposing an IBM System Storage DS5000 solution to aninstalled EMC customer. Which IBM resource should the Business Partner engage to assist withcompetitive sales strategies against EMC?()ACompeteline BExecutive Briefing Center CCompetitive Benchmark Center DField Technical Support Specialist (FTSS)

单选题The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP.  How can the improvement be verified()Acheck the output of the vmstat command on LINUXBcheck the performance reports via Tivoli Storage Productivity Center for DataCcheck the performance reports via Tivoli Storage Productivity Center for DiskDcheck the output of the iostat command on AIX

单选题An IBM Business Partner suggests an IBM System Storage DS8000 to a customer with a SAN   that is now configured with an EMC Symmetrix subsystem disk.  The customer wants to determine if new HBAs and software upgrades are needed on the servers if the EMC storage is replaced by the DS8000 What document must be carefully read to help address the customer’s concerns()AIBM System Storage DS8000: Host Systems Attachment GuideBDS8000 Interoperability MatrixCIBM System Storage DS8000: Introduction and Planning GuideDIBM System Storage Solution Handbook

单选题A Business Partner has proposed an IBM System Storage DS8700 that will have several AIX, Windows, and Sun Solaris servers attached via SAN. The customer has asked for detailed documentation on the steps needed to install the latest adapter drivers.  What is the best document the Business Partner can suggest to accomplish this requirement()Athe IBM System Storage DS8000 Interoperability MatrixBthe IBM System Storage DS8000 Introduction and Planning GuideCthe IBM System Storage DS8000 Host System Attachment GuideDthe IBM System Storage DS8000 User’s Guide

单选题An IBM Business Partner sells an IBM System Storage DS8700 to a customer.  Who is responsible for the installation and set up of the storage server()Apurchasing customerBIBM Installation Readiness TeamCIBM Customer EngineerDIBM Business Partner

单选题A customer is interested in purchasing a new IBM System Storage DS8000 solution to consolidateolder ESS and F20 storage systems. What should be done first, prior to final proposaldevelopment?()Aperform a Disk Magic study Breview eConfig with a technical specialist Cconfirm that the customer has enough ports available in the SAN infrastructure Dsubmit configuration to IBM System Storage Interoperability Center for validation

单选题A customer using an IBM System Storage DS8300 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()Ausing the vmstat command on the AIX servers connected via SAN to the DS8300 systemBlooking at the number of I/O managed by the DS8300 systemCreading the performance reports via TotalStorage Productivity Center for DiskDgenerating reports using the TotalStorage Expert

单选题A customer has an IBM System Storage DS8100 with 128 DDMs and needs to add additional capacity.  What must be verified by the Business Partner during the visit to the computer room()Athe space for the upgrade to a DS8700Bthe space on the left of the DS8000 for an expansion frameCthe space on the right of the DS8000 for an expansion frameDthe space to install additional DDMs in the base frame

单选题A pharmaceutical company has a requirement for 8.5 TB of usable storage for a new data center. The customer has multiple host applications running on Solaris, Windows 2003, HP-U/X, Linux, and IBM System i platforms.  Which IBM System Storage DS8000 volume configuration providesthe best performance and highest availability for this customer()ARAID 3BRAID 5CRAID 6DRAID 10

单选题A customer using an IBM System Storage DS8700 is facing performance problems. After the analysis by the technical specialist, the diagnosis indicates that the cache hits may be improved by a cache upgrade.  How can the system be monitored in order to check the benefits of the cache upgrade()Ausing the vmstat command on the AIX servers connected via SAN to the DS8700 systemBlook at the IOPS using the DS8700Creading the performance reports via Tivoli Storage Productivity Center for DiskDgenerating reports using theTotalStorage Expert