P5架构
P5架构
相关考题:
在设备冷却系统中,若飞机工作在除烟模式,此时()。 A、供气扇不工作,排气扇工作,P5上的供气扇灯亮B、排气扇不工作,供气扇工作,P5上的排气扇灯亮C、供气扇不工作,排气扇工作,P5上的供气扇灯不亮D、供气扇工作,排气扇工作,P5上的供、排气扇灯均不亮
前趋图(Precedence Graph) 是一个有向无环图,记为:→={(Pi,Pj )|Pi must complete before Pj may strat}。假设系统中进程P={P1,P2,P3,P4,P5,P6,P7,P8},且进程的前驱图如下:那么前驱图可记为:( )A. →={(P2,P1),(P3,P1),(P4,P1),(P6,P4),(P7,P5),(P7,P6),(P8,P7)}B. →={(P1,P2),(P1,P3),(P1,P4),(P2,P5),(P5,P7),(P6,P7),(P7,P8)}C. →={(P1,P2),(P1,P3),(P1,P4),(P2,P5),(P3,P5),(P4,P6),(P5,P7),(P6,P7),(P7,P8)}D. →={(P2, P1), (P3,P1),(P4,P1),(P5,P2),(P5,P2),(P5,P3),(P6,P4),(P7,P5), (P7,P6),(P8,P7)}
For the p5 590 and p5 595 servers, the HMC must be directly attached. Why is the use of a private service network between HMC and the p5 590 required?()A、The Bulk Power Controllers are dependent upon the HMC to provide them with DHCP addresses.B、A firewall is required to isolate the private network from any of the open networks to which the HMC is attached.C、Network communications can be implemented through an open network. No private network is required but it is recommended.D、All p5 590 and 595 servers are shipped with one service processor card. A private network is required to manage DHCP addresses.
关于机载S模式应答机旁瓣抑制P5描述正确的有()。A、P5脉冲覆盖着数据块始端的两个同步信号之间的相位翻转时刻B、P5脉冲的电平高于P1、P2脉冲和P6数据块的旁瓣,但比主瓣电平低9dBC、P5脉冲在P1、P2之间发射D、P5脉冲在P6数据块之后2秒发射
Companycom recently ordered a p5 570 and an HMC. Prior to delivery, two additional p5 570 servers were added to the order. Upon installation, the system administrator noticed that they do not have a method to connect the p5 570 servers to the HMC. Which of the following will allow them to connect all servers to the HMC?()A、An 8-port adapter to the HMCB、A hub for the private networkC、An additional Ethernet card to the HMCD、An additional Ethernet card for each partition
Companycom is considering a partitioned solution which will require cumulative rPerf total of 150. The original sizing came back recommending a 32-way p5 590. However, they have a requirement for future scalability and availability is important. Which of the following would be the best reason to recommend a p5 595?()A、The p5 595 would allow for CODB、The p5 595 includes the Advanced Power Virtualization hardware and softwareC、The p5 595 is priced the same as the p5 590 given the same number/type of CPUsD、The p5 595 performance would be equivalent to the p5 590 given the same number/type of CPUs
Companycom has several CR3 HMCs managing their p690 servers. They have purchased a new p5 570 and would like to manage the new system with an existing HMC. What is required to support this environment?()A、Free up one HMC and update the software for use with the p5 570B、Connect the new p5 570 server to an existing HMC and manage the p690s and p5 570 from that HMCC、Order a new HMC to support the new p5 570 server since the CR3 HMC is not supported for a p5 570D、Backup the HMC to DVD-RAM and select HMC migrate to move all the profile data to the new HMC software
A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()A、A CD or DVD with installation mediaB、An internal SCSI adapter in the target LPARC、An Ethernet adapter for access to an FTP serverD、Advanced Power Virtualization feature of the p5 590
A client has an existing p5 570 that is directly connected to a HMC. The customer will be purchasing another p5 570. Which of the following solutions would be appropriate to provide HMC connectivity to the second p5 570?()A、Implement a proxy server to provide multiple sources to one destination B、Purchase an additional Ethernet adapter for each p5 570 to provide connectivity between the two C、Purchase a network hub or switch so both p5 570s can connect to the single HMC D、Purchase an additional HMC since multiple HMC are required when more than one POWER5 Enterprise class server is used Purchase an additional HMC since multiple HMC? are required when more than one POWER5 Enterprise class server is used
A customer currently has five partitioned POWER4 systems and is adding new systems. When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()A、Order a new HMC to support the p5 system.B、Attach the new p5 system to the existing HMC.C、Upgrade the existing HMC to accommodate both the POWER4 and p5 systems.D、Do nothing. This system does not require an HMC.
Which server houses the database partitions in the AIX BCU V2.1? ()A、 IBM System p5 570 B、 IBM System p5 575 C、 IBM System p5 590 D、 IBM System p5 595
单选题Which server houses the database partitions in the AIX BCU V2.1? ()A IBM System p5 570 B IBM System p5 575 C IBM System p5 590 D IBM System p5 595
单选题One of the key decision making factors in a very competitive opportunity will be cost. Companycom needs an aggregate rPerf rating of 120. What is the best solution?()ATwo p5 570 16 way 1.9 MHz machinesBOne p5 590 32 way 1.65 MHz machinesCOne p5 595 32 way 1.65 MHz machinesDTwo p5 570 16 way 1.65 MHz machines
单选题华为两地三中心容灾方案支持的架构是()。A并联架构,级联架构B并联架构,星型架构C级联架构,星型架构D并联架构,级联架构,星型架构