单选题A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()ANPIVBvSCSICArbitrated loopDConverged adapter

单选题
A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()
A

NPIV

B

vSCSI

C

Arbitrated loop

D

Converged adapter


参考解析

解析: 暂无解析

相关考题:

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server.Which limitation must be considered when planning the system configuration?()A.A VIO server requires a dedicated LHEA port.B.There is a limit of 32 LPARs per virtual LAN.C.Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D.Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、ImplementPowerHA SystemMirror on both VIO servers.B、ConfigureEtherchannel between the client LPARs and the two VIO serversC、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()A、NPIV and vSCSI both require multipathing in VIO Server only. B、NPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. C、NPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. D、NPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()A、NPIV andvSCSI both require multipathing in VIO Server only.B、NPIV requiresmultipathing software on client LPARs, vSCSI requires multipathing software on VIO Server.C、NPIV requiresmultipathing software on VIO Server, vSCSI requires multipathing software on client LPARs.D、NPIV requiresmultipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()A、NPIVB、vSCSIC、Arbitrated loopD、Converged adapter

Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()A、Shared Ethernet Adapters and Virtual SCSI services require separate Virtual IO Servers.B、Virtualized adapters require essentially the same Virtual IO Server resources regardless of adapter type.C、Shared Ethernet Adapters require significantly more Virtual IO Server resources than Virtual SCSI services.D、Virtual SCSI services require significantly more Virtual IO Server resources than Shared Ethernet Adapters.

A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsB、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down.  Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()A、Implement PowerHA SystemMirror on both VIO servers.B、Configure Etherchannel between the client LPARs and the two VIO serversC、Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.D、Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()A、Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionB、Add iSCSI cards to the servers and direct attach them to a DS300 dual controller modelC、Use clustered NAS solution with redundant gigabit network connectionsD、Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

A customer has Windows servers and applications that use block I/O. The customer cannot affordthe cost of a fibre channel infrastructure but still requires shared storage. Which configurationmeets these requirements at the lowest cost?()A、iSCSI HBAs and N3400B、MicrosoftiSCSI initiator and N3400C、MicrosoftiSCSI initiator and DS3400D、SAN04B-R multi-protocol router and DS3400

A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()A、A VIO server requires a dedicated LHEA port.B、There is a limit of 32 LPARs per virtual LAN.C、Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.D、Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()A、An HMC is required for dual VIO servers.B、Dual VIO servers require a split backplane.C、A dual VIO enablement code must be entered from the ASMI interface.D、The second VIO server must be created using the IVM command line interface.

Which statement is true regarding Oracle Shared Server architecture?()A、A dispatcher can support multiple client connects concurrently while a shared server process can be dedicated to only one dispatcher. B、Under the Oracle Shared Server architecture, client-user processes connect to shared user processes.C、Each dispatcher has its own request queue, which is monitored every three seconds by the dispatcher. D、Oracle Shared Server required Oracle Net Service even if the client and shared server processes reside on the same machine.

单选题While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()ANPIV and vSCSI both require multipathing in VIO Server only. BNPIV requires multipathing software on client LPARs, vSCSI requires multipathing software on VIO Server. CNPIV requires multipathing software on VIO Server, vSCSI requires multipathing software on client LPARs. DNPIV requires multipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

单选题During a planning session, the customer indicates that they intend to build two independent two- Node clusters (cluster ’A’ and ’B’) that will be provided shared storage form an IBM TotalStorage FAStT900 server. The customer intends to present 2 LUNs to cluster ’A’, and 2 LUNs to cluster ’B’. All hosts will be dual attached via fibre.  What additional hardware or software is necessary to make this a valid configuration?()A SAN switchesB Fibre channel Hub(s)C IBM Storage Manager AgentsD IBM Subsystem Device Driver

单选题A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()AImplement PowerHA SystemMirror on both VIO servers.BConfigure Etherchannel between the client LPARs and the two VIO servers.CConfigure Network Interface Backup between the two VIO servers and use each VIO server to access the network.DImplement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

单选题A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()AA VIO server requires a dedicated LHEA port.BThere is a limit of 32 LPARs per virtual LAN.CTwo VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.DTwo VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.

单选题A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()AImplementPowerHA SystemMirror on both VIO servers.BConfigureEtherchannel between the client LPARs and the two VIO serversCConfigure Network Interface Backup between the two VIO servers and use each VIO server to access the network.DImplement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.

单选题A customer has Windows servers and applications that use block I/O. The customer cannot affordthe cost of a fibre channel infrastructure but still requires shared storage. Which configurationmeets these requirements at the lowest cost?()AiSCSI HBAs and N3400BMicrosoftiSCSI initiator and N3400CMicrosoftiSCSI initiator and DS3400DSAN04B-R multi-protocol router and DS3400

单选题A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers.   Which technology is recommended for this proposal?()ANPIVBvSCSICArbitrated loopDConverged adapter

单选题Which statement is true regarding Oracle Shared Server architecture?()AA dispatcher can support multiple client connects concurrently while a shared server process can be dedicated to only one dispatcher. BUnder the Oracle Shared Server architecture, client-user processes connect to shared user processes.CEach dispatcher has its own request queue, which is monitored every three seconds by the dispatcher. DOracle Shared Server required Oracle Net Service even if the client and shared server processes reside on the same machine.

单选题A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()AMove the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAsBMove the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.CMove the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.DMove the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.

单选题While using virtualization to share SAN adapters on a server, how does Node Port ID Virtualization (NPIV) differ from Virtual SCSI (vSCSI) related to the use of multipathing software?()ANPIV andvSCSI both require multipathing in VIO Server only.BNPIV requiresmultipathing software on client LPARs, vSCSI requires multipathing software on VIO Server.CNPIV requiresmultipathing software on VIO Server, vSCSI requires multipathing software on client LPARs.DNPIV requiresmultipathing and MPIO software on VIO Server LPARs, vSCSI requires multipathing software on VIO Server and MPIO on client LPARs.

单选题A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()A Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.B Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.C Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.D Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

单选题Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()AAllocate the CD to the VIO Server and NFS export the CD to the user LPARsBAllocate the CD to one of the user LPARs and config the VIO Server to NFS import itCAllocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI deviceDAllocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

单选题A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()AAdd redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solutionBAdd iSCSI cards to the servers and direct attach them to a DS300 dual controller modelCUse clustered NAS solution with redundant gigabit network connectionsDAdd redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

单选题A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()AAn HMC is required for dual VIO servers.BDual VIO servers require a split backplane.CA dual VIO enablement code must be entered from the ASMI interface.DThe second VIO server must be created using the IVM command line interface.