单选题Operation of the valve control release on a fixed CO2 system must immediately().Arelease CO2 to the protected spaceBsecure all mechanical ventilation in the protected spaceCsound the rig's general alarm signal for a fireDsound an alarm in the ballast control room

单选题
Operation of the valve control release on a fixed CO2 system must immediately().
A

release CO2 to the protected space

B

secure all mechanical ventilation in the protected space

C

sound the rig's general alarm signal for a fire

D

sound an alarm in the ballast control room


参考解析

解析: 暂无解析

相关考题:

Operation of the valve control release on a fixed CO2 system must immediately ______.A.release CO2 to the protected spaceB.secure all mechanical ventilation in the protected spaceC.sound the rig’s general alarm signal for a fireD.sound an alarm in the ballast control room

The CO2 flooding system is actuated by a sequence of steps which are ______.A.break glass, pull valve, break glass, pull cylinder controlB.sound evacuation alarm, pull handleC.open bypass valve, break glass, pull handleD.open stop valve, open control valve, trip alarm

You must take good care of the drainage cock of the air control system. Because lead scale formed which might malfunctions the pilot control valve and other instruments.A.the temperatureB.the rustC.the pressureD.the humidity

Which describes the operation required to move to anew release level of system firmware?() A.DeferredB.TransientC.ConcurrentD.Disruptive

A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by ______.A.one controlB.two controlsC.three controlsD.none of the above

You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take?A.Cut in another IG fan to increase gas flowB.Open the pressure control valve until the pressure increasesC.Open the tank isolation valve to the fully open positionD.Reduce the pumping rate

Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

Which describes the operation required to move to anew release level of system firmware?()A、DeferredB、TransientC、ConcurrentD、Disruptive

当中央控制室手动报警站MFS-1301被拉下时,相应的报警描述为()A、CCR STATE LIGHT HAZARDALARM SIREM、PRE-RELEASE BUZZER AND LIGHT、RELEASE TO CO2 PANEL CONTROL RM和ESD 2-2 TO CCPB、CCR STATE LIGHT HAZARDALARM SIREM、PRE-RELEASE BUZZER AND LIGHT、RELEASE TO CO2 PANEL CABINETS RM和ESD 2-2 TO CCPC、CCR STATE LIGHT HAZARDALARM SIREM、PRE-RELEASE BUZZER AND LIGHT、RELEASE TO CO2 PANEL UPS RM和ESD 2-2 TO CCPD、CCR STATE LIGHT HAZARDALARM SIREM、PA HAZARD和ESD 3-A TO CCP

单选题Which of the listed pressure control valves would be used to establish the maximum operating pressure of a hydraulic system?()APressure-reducing valveBUnloading valveCCounterbalance valveDPressure-relief valve

单选题Which of the valves listed is NOT considered to be a hydraulic system directional control valve?()ASpring-centered valveBUnloading valveCThree-position valveDTwo-position valve

单选题The C02 flooding system is actuated by a sequence of steps which are().Abreak glass,pull valve,break glass,pull cylinder controlBsound evacuation alarm,pull handleCopen bypass valve,break glass,pull handleDopen stop valve,open control valve,trip alarm

单选题A fixed CO2 system on a ship with a capacity of over 300 lbs (136 kilograms) CO2 which protects spaces other than tanks must have().Atwo or more releasing stationsBautomatic release in event of a fireCan audible alarm and time delayDan audible and visible alarm

单选题Operation of the valve control release on a fixed CO2 system must immediately().Arelease CO2 to the protected spaceBsecure all mechanical ventilation in the protected spaceCsound the rig's general alarm signal for a fireDsound an alarm in the ballast control room

单选题The remote control for a fixed fire extinguishing system should be().Apainted red and labeledBconcealed from the crewCprotected by plexiglassDpadlocked

单选题CO2 cylinders equipped with pressure actuated discharge heads will discharge automatically when().Athe discharge valve is openBthe control box glass is brokenCpressure from the control cylinders is detectedDthe control cylinders have been completely discharged

单选题The mechanical exhaust valve operation system is replaced by()in an electronic controlled ME engine.Aa system with a Hydraulic Power Supply (HPS) unitBa system with roller guides for exhaust valvesCa system with an electronically controlled Alpha LubricatorDa system directly powered by electric motor

单选题The key feature of the Sulzer RT-flex system is that it gives complete freedom in the and operation of fuel injection and exhaust valve actuation()AmeteringBcontrolCusingDtiming

单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().Aactuate an alarm and open the engine room control valveBactuate an alarm and open the engine room CO2 releasing valveCopen the engine room control valve and shut off engine room ventilation fansDopen the engine room control valve and then the CO2 releasing valve

单选题Actuating the CO2 fixed system causes the shutdown of the().Afuel supplyBexhaust ventilationCsupply and exhaust ventilationDmechanical and natural ventilation

单选题You are discharging cargo and the inert gas system is in operation to inert the tanks. The pressure in a tank being discharged starts to drop below the allowable limit. What action should you take? ()ACut in another IG fan to increase gas flowBOpen the pressure control valve until the pressure increasesCOpen the tank isolation valve to the fully open positionDReduce the pumping rate

多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed

单选题A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by().Aone controlBtwo controlsCthree controlsDnone of the above

单选题A crew member reports that the high-pressure alarm light of a low-pressure CO2 fixed fire extinguishing system is illuminated. The most probable cause of this condition would be that().Aan air leak has developed in the tankBthe tank cooling system has malfunctionedCthe pilot cylinder discharge valve is leakingDan excessive amount of insulation has been installed on the tank and piping

单选题Your vessel is equipped with a fixed CO2 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?()AUse the CO2 system and evacuate the engine roomBUse the fire main system and evacuate the engine roomCEvacuate the engine room and use the CO2 systemDEvacuate the engine room and use the fire main system

单选题Which of the listed devices would be installed at a control system air pressure reducing station?()AMoisture separatorBVacuum breakerCLubricatorDNon-return valve

单选题Control valves of a CO2 system may be located within the protected space when().Ait is impractical to locate them outsideBthere is also a control valve outsideCthe CO2 cylinders are also in the spaceDan automatic heat-sensing trip is installed

单选题While on watch in the engine room, you hear a continuous sounding of the general alarmWhich of the following actions should you take FIRST?()ASecure the burners then proceed to your assigned boat stationBStart the fire pump and establish flow to the fire mainCOpen the guardian valve and standby to maneuverDOpen the master control valves on the fixed CO2 system