A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by ______.A.one controlB.two controlsC.three controlsD.none of the above
A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by ______.
A.one control
B.two controls
C.three controls
D.none of the above
相关考题:
In the event of fire in a machinery space,______.A.the fixed carbon dioxide system should be used only when all other means of extinguishment have failedB.the fixed carbon dioxide system should be used immediately,as it is the most efficient means of extinguishmentC.water in any form should not be used as it will spread the fireD.the space should be opened 5 minutes after flooding CO2 to prevent injury to personnel
Which statement concerning carbon dioxide is FALSE ________.A.It displaces the oxygen in the airB.It cannot be seenC.It cannot be smelledD.It is safe to use near personnel in a confined space
An advantage of an ABC dry chemical over a carbon dioxide fire extinguisher is ______.A.lack of toxicityB.the multipurpose extinguishing abilityC.burn-back protectionD.cooling ability
Large volumes of carbon dioxide are safe and effective for fighting fires in enclosed spaces, such as in a pumproom, provided that the ______.A.persons in the space wear gas masksB.persons in the space wear damp cloths over their mouths and nostrilsC.ventilation system is secured and all persons leave the spaceD.ventilation system is kept operating
Deep-fat cooking equipment shall be fitted with the following:()A、An automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationB、Controls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewC、Arrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemD、an alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
单选题An advantage of an ABC dry chemical over a carbon dioxide extinguisher is().Alack of toxicityBthe multipurpose extinguishing abilityCburn-back protectionDcooling ability
单选题The remote control for a fixed fire extinguishing system should be().Apainted red and labeledBconcealed from the crewCprotected by plexiglassDpadlocked
单选题The danger associated with using carbon dioxide in an enclosed space is().AfrostbiteBskin burnsCasphyxiationDan explosive reaction
单选题For which of the listed classes of fire combinations would carbon dioxide be most suitable as the extinguishing agent ().AClass A and class BBClass B and class CCClass A and class CDClass C, class D, and class E
单选题Carbon dioxide flooding system is used for extinguishing fires because it reduces the concentration of oxygen in the air to().Aflashing pointBcombustion pointCauto-ignition pointDlower explosive limit
单选题According to the passage, the greatest part of the solar energy that reaches the Earth is _____.Areflected back to space by snow and iceBconcentrated at visible wavelengthsCabsorbed by carbon dioxide moleculesDabsorbed by atmospheric water vapor
单选题In order to release CO2 to the machinery spaces from a fixed fire extinguishing system, you must().Aactuate an alarm and open the engine room control valveBactuate an alarm and open the engine room CO2 releasing valveCopen the engine room control valve and shut off engine room ventilation fansDopen the engine room control valve and then the CO2 releasing valve
多选题Deep-fat cooking equipment shall be fitted with the following:()AAn automatic or manual fixed extinguishing system tested to an appropriate standardacceptable to the OrganizationBControls for manual operation of the fire-extinguishing system which are clearlylabeled for ready use by the crewCArrangements for automatically shutting off the electrical power upon activation of thefire-extinguishing systemDan alarm for indicating operation of the fire-extinguishing system in the galley wherethe equipment is installed
单选题Controls for a fixed carbon dioxide system shall be mounted().Adirectly outside the space protected by the systemBas near the gas cylinders as possibleCin the pilothouseDon the main deck near the bow
单选题A fixed carbon dioxide extinguishing system for a machinery space,designed WITHOUT a stop valve in the line leading to the protected space,is actuated by().Aone controlBtwo controlsCthree controlsDnone of the above
单选题Large volumes of carbon dioxide are safe and effective for fighting fires in enclosed space, such as in the pumproom, provided that the().Apersons in the space wear gas masksBpersons in the space wear damp cloths over their mouths and nostrilsCventilation system is secured and all persons leave the spaceDventilation system is kept operating
单选题What is NOT a characteristic of carbon dioxide fire-extinguishing agents?()AEffective even if ventilation is not shut downBWill not deteriorate in storageCNon-corrosiveDEffective on electrical equipment
单选题Which of the following statements is true concerning carbon dioxide when used as a fire extinguishing agent?()ACarbon dioxide is corrosive when exposed to fireBCarbon dioxide should be applied slowly to a large engine room fireCIts total cooling effect is far greater than waterDIts smothering effect is excellent for class B fires
单选题Which types of portable fire extinguishers are designed for use on electrical fires?()ADry chemical and carbon dioxideBFoam (stored pressure) and soda-acidCCarbon dioxide and foam (stored pressure)DDry chemical and soda-acid
多选题On what conditions may an exemption certificate,exempting from the requirement to install a fixed fire extinguishing system in a cargo space,be issued?()AThe ship is constructed and solely intended for carriage of ore, coal, grain, unseasoned timber, non-combustible cargoes or cargoes which according to the Administration constitute a low fire riskBSteel hatch covers and effective means of closing all ventilators and other openings to the cargo space are fittedCA fixed deck foam system is be fitted in lieu of the cargo space extinguishing systemDThe vessel is less than 10 000 gross tonnage
单选题After extinguishing a paint locker fire using the fixed CO2 system,the next action is to have the space().Aopened and burned material removedBleft closed with vents off until all boundaries are coolCchecked for oxygen contentDdoused with water to prevent reflash
单选题While you are working in a space,the fixed CO2 system is accidentally activated.You should().ASecure the applicators to preserve the charge in the cylindersBContinue with your work as there is nothing you can do to stop the flow of CO2CRetreat to fresh air and ventilate the compartment before returningDMake sure all doors and vents are secured
单选题Why should you wear a self-contained breathing apparatus before entering the engine room after the fixed CO2 system has been discharged to combat a major fire?()ABecause carbon dioxide dilutes the oxygen concentration in the atmosphere and may cause asphyxiationBBecause carbon dioxide breaks down in a fire into carbon monoxide which may cause blood poisoning in the person breathing this gasCBecause carbon dioxide is a colorless and odorless gas that becomes highly toxic in the presence of high temperatures and will quickly incapacitate a person exposed to this gasDThis action is unnecessary as carbon dioxide is not poisonous nor toxic but is a relatively harmless gas
单选题The supply of carbon dioxide used in the fixed extinguishing system aboard a cargo vessel MUST be at least sufficient for().Aall the spaces of a vesselBall cargo spacesCthe engine room and largest cargo spaceDthe space requiring the largest amount
单选题Large volumes of carbon dioxide are safe and effective for fighting fires in enclosed spaces,such as in a pumproom,provided that the().Apersons in the space wear gas masksBpersons in the space wear damp cloths over their mouths and nostrilsCventilation system is secured and all persons leave the spaceDventilation system is kept operating
单选题On a ship,a fixed carbon dioxide or other approved system must be installed().Awhere oil or chemical drums are storedBin all battery storage locationsCin paint lockersDin all of the above locations
单选题Where foam extinguishing systems are provided on a ship,each machinery flat in the protected space must have a(n)().AcoamingBalarmCdrainDfire sensor