单选题When fighting a spreading fire resulting from a broken fuel line, you should FIRST ().Alook for a CO2 extinguisherBuse a soda acid extinguisherCshut off the fuel supplyDsmother the fire with rags
单选题
When fighting a spreading fire resulting from a broken fuel line, you should FIRST ().
A
look for a CO2 extinguisher
B
use a soda acid extinguisher
C
shut off the fuel supply
D
smother the fire with rags
参考解析
解析:
暂无解析
相关考题:
The fire extinguishing action of CO 2 comes mostly from ______.A.breaking the fire chemical chain reactionB.smotheringC.coolingD.isolating the heat from the fuel
When fighting a large fire on your vessel and attacking it from ABOVE the space on fire,it is important to ______.A.Rotate personnel,due to heat stressB.Station personnel on the hot deck immediately above the fireC.Stay low by crouching or kneeling on deckD.All of the above
Fighting a fire in the galley poses the additional threat of ______.A.contaminating food with extinguishing agentB.spreading through the engineering spaceC.loss of stabilityD.a grease fire in the ventilation system
单选题If you are fighting a fire below the main deck of your vessel,which action is most important concerning the stability of the vessel?().AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题When fighting a spreading fire resulting from a broken fuel line, you should FIRST ().Alook for a CO2 extinguisherBuse a soda acid extinguisherCshut off the fuel supplyDsmother the fire with rags
单选题The needle valve in a fuel valve will () when the fuel pressure action on the needle valve tapered face exerts a force lower than that of the spring compression.Abe jammedBbe openedCbe seatedDbe broken
单选题The straight stream capability of an all-purpose nozzle is used in fighting a class A fire to().Ashield fire fighters from radiant heatBbreak up burning materialCget the most water possible on the fireDdrive heat and smoke ahead of the fire fighters
单选题If you are fighting a fire below the main deck of your vessel,which action is most importantconcerning the stability of the vessel? ()AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题What is an advantage of using foam in fire fighting?()AIt is effective in controlling fire in flowing oil such as coming from a broken fuel lineBIt absorbs heat from materials that could cause reignitionCMost foams can be used jointly with dry chemical extinguishing agents to attack a fire by two methods of extinguishmentDOnce the surface is blanketed with foam and the fire is extinguished,no further foam is required
单选题You are transferring fuel from the storage tanks to the day tanks by means of an electric fuel oil transfer pumpIf the pump motor catches fire, you would FIRST ().Asecure the fuel manifoldBshut off power to the pumpCshut off the power ventilationDspray water on the fire
单选题The FIRST course of action in fighting a fire in a cargo or fuel oil tank is to ().Asecure all openings to the tankBdischarge an initial charge of CO2 with a hand portable extinguisherCdirect a fire hose into the tank and energize the fire mainDspray the tank boundaries with a fire hose to promote cooling
单选题When the vessel entering the dock, the first work that engineer should contact with the shipyard ()Areleasing the boiler waterBthe explosion detecting and cleaning for the fuel tankCthe docking project related itemDshore power and fire fighting water supply
单选题The best method of extinguishing a class A fire is to().Aremove oxygen from the areaBcool fuel below ignition temperatureCsmother with CO2Dsmother fire with foam
单选题A fire is considered "under control" when ().Aall hands are at their fire stationsBall fire-fighting equipment is at the sceneCthe fixed systems are activatedDthe fire is contained and no longer spreading
单选题When possible,what is the FIRST step in fighting an engine fuel-pump fire which results from a broken fuel line?()ASecure all engine room doors,hatches,and ventsBClose the fuel line valveCCheck the spread of the fire with foamDCast the barge off the wharf
单选题The FIRST step to take in fighting an engine room fire resulting from a ruptured fuel oil service line, is to ().Aevacuate all engine room personnelBfight the fire with hand portable extinguishersCactivate the mainCO2 bankDstop the flow of leaking fuel oil
单选题It is necessary to secure the forced ventilation to a compartment where there is a fire to().Aallow the exhaust fans to remove smokeBextinguish the fire by carbon monoxide smotheringCprevent additional oxygen from reaching the fireDprotect fire fighting personnel from smoke
单选题When sailing in cold zones, the() should be drained of water.Athe ventilation pipeBthe water line for fire fighting on the deckCthe fuel oil lineDthe water supplying line in bath room
单选题The longer the ignition delay period resulting from improper use of low cetane fuel, the ()Aless fuel will enter the cylinderBhigher the cylinder combustion temperatureCmore complete the fuel combustionDmore rapid the rise in combustion pressure
单选题When fighting an electrical fire, you should first ().Astop ventilation to the areaBstop the vesselCsecure electricity to the circuitDapply CO2 to the fire
单选题When sailing in cold zones, the() should be heated.Athe steering gear roomBthe fire fighting pipe lineCthe fuel oil tankDthe bath room
单选题The fire extinguishing action of CO2 comes mostly from ().Abreaking the fire chemical chain reactionBsmotheringCcoolingDisolating the heat from the fuel
单选题The best method of extinguishing a class A fire is to ().Aremove oxygen from the areaBsmother fire with foamCsmother fire with CO2Dcool fuel below ignition temperature
单选题In fighting a fire in a fuel tank, the FIRST action you should attempt is to ().Asecure all sources of fresh air to the tankBbegin transferring the fuel to other tanksCtop off the tank to force out all vaporsDstation someone at the fixed CO2 release controls
单选题When possible,what should be the FIRST step in combating a fire on deck resulting from a cargo overflow or a leaking cargo line?()ABlanket the cargo spill with foamBPrevent the spread of fire with a foam damCApply CO2 on burning fuel at its sourceDShut off the transfer of cargo
单选题When fighting a fire in an enclosed space,the hose team should crouch as low as possible to().Aprotect themselves from smokeBobtain the best available airCallow the heat and steam to pass overheadDAll of the above
单选题When fighting a fire with a portable dry chemical fire extinguisher,the stream should be directed().Aover the top of the flamesBoff a bulkhead into the fireCin front of the fireDat the base of the fire
单选题When fighting fires in spaces containing bottles of LPG (liquefied petroleum gas),you should ().Aattempt to isolate the fire from the LPGBcool the bottles or remove them from the fire areaCsee that the valves on all LPG bottles are closedDplace insulating material over the bottles