When fighting a large fire on your vessel and attacking it from ABOVE the space on fire,it is important to ______.A.Rotate personnel,due to heat stressB.Station personnel on the hot deck immediately above the fireC.Stay low by crouching or kneeling on deckD.All of the above
When fighting a large fire on your vessel and attacking it from ABOVE the space on fire,it is important to ______.
A.Rotate personnel,due to heat stress
B.Station personnel on the hot deck immediately above the fire
C.Stay low by crouching or kneeling on deck
D.All of the above
相关考题:
what is your position (station ) in the muster lists ,for example ,during the fire fighting ,abandon vessel ,oil pollution prevention etc ?
At the earliest indication of fire aboard your vessel, you must FIRST ______.A.locate the fireB.determine which type of fire is burningC.sound the alarmD.fight the fire
A fire has broken out on the stern of your vessel. You should maneuver your vessel so the wind ______.A.comes over the bowB.blows the fire back toward the vesselC.comes over the sternD.comes over either beam
A fire hose with a nozzle attached must be connected to each hydrant except when exposed to heavy weather or when the ______.A.Fire hose might be damaged by cargo operationsB.Vessel is in portC.Fire-main system is not chargedD.Fire pumps are used for purposes other than supplying water to the fire main
Where do you post your ()(火势控制图)?A、fire control planB、fire controlC、fire planD、fire-fighting plan
单选题If you are fighting a fire below the main deck of your vessel,which action is most important concerning the stability of the vessel?().AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题When fighting a spreading fire resulting from a broken fuel line, you should FIRST ().Alook for a CO2 extinguisherBuse a soda acid extinguisherCshut off the fuel supplyDsmother the fire with rags
单选题Fire fighting equipment requirements for a particular vessel may be found on the().ACertificate of InspectionBCertificate of SeaworthinessCClassification CertificateDCertificate of Registry
单选题At night while the ship is tied up to the dock,a fire breaks out in a cargo hatch. After sounding the alarm,what should the person on watch do?()ABegin fighting the fire immediatelyBAwait further orders from the MasterCLet go the lines to let the vessel drift to an anchorageDSend a person to summon the shore authorities
单选题If you are fighting a fire below the main deck of your vessel,which action is most importantconcerning the stability of the vessel? ()AShutting off electricity to damaged cablesBPumping fire-fighting water overboardCManeuvering the vessel so the fire is on the lee sideDRemoving burned debris from the cargo hold
单选题The basic training in fire prevention and fire fighting should include the theoretical elements which should cover ().Athe three elements of fire and explosionBlower and upper flammable limitsCclassification of flies and applicable extinguishing agentsDAll of the above
单选题When should a fire be ventilated?()AWhen attacking the fire directlyBWhen using a steam smothering systemCWhen using the fixed CO2 systemDAll of the above
单选题When two fire hose teams are attacking a fire they should().Ause different fire hose pressuresBuse fire hoses of different sizesCnot attack the fire from opposite sidesDnot wear protective clothing
单选题When the vessel entering the dock, the first work that engineer should contact with the shipyard ()Areleasing the boiler waterBthe explosion detecting and cleaning for the fuel tankCthe docking project related itemDshore power and fire fighting water supply
单选题Your vessel is equipped with a fixed C02 system and a fire main system. In the event of an electrical fire in the engine room what is the correct procedure for fighting the fire?().AUse the C02 system and evacuate the engine roomBUse the fire main system and evacuate the engine roomCEvacuate the engine room and use the C02 systemDEvacuate the engine room and use the fire main system
单选题A fire is considered "under control" when ().Aall hands are at their fire stationsBall fire-fighting equipment is at the sceneCthe fixed systems are activatedDthe fire is contained and no longer spreading
单选题When possible,what is the FIRST step in fighting an engine fuel-pump fire which results from a broken fuel line?()ASecure all engine room doors,hatches,and ventsBClose the fuel line valveCCheck the spread of the fire with foamDCast the barge off the wharf
单选题Which space(s) on your cargo vessel must have a fire detection system?()AAny compartment containing explosivesBAny compartment adjacent to one containing explosivesCEnclosed spaces which are specially suitable for vehiclesDAll of the above
单选题It is necessary to secure the forced ventilation to a compartment where there is a fire to().Aallow the exhaust fans to remove smokeBextinguish the fire by carbon monoxide smotheringCprevent additional oxygen from reaching the fireDprotect fire fighting personnel from smoke
单选题Ship fire-fighting organization includes ().Ageneral alarm and fire control plansBmuster stations and duties of individualCpatrol systemDAll of the above
单选题At the earliest indication of fire aboard your vessel, you must FIRST().Alocate the fireBdetermine which type of fire is burningCsound the alarmDfight the fire
单选题A fire has broken out on the stern of your vessel. You should maneuver your vessel so the wind ().Acomes over the bowBblows the fire back toward the vesselCcomes over the sternDcomes over either beam
单选题When fighting an electrical fire, you should first ().Astop ventilation to the areaBstop the vesselCsecure electricity to the circuitDapply CO2 to the fire
单选题The basic training in fire prevention and fire fighting should include the practical elements which should allow the trainees to acquire the ability to ().Ause self-contained breathing apparatusBuse various types of portable fire extinguishersCeffect a rescue in a smoke-filled space wearing breathing apparatusDAll of the above
单选题When fighting a fire in an enclosed space,the hose team should crouch as low as possible to().Aprotect themselves from smokeBobtain the best available airCallow the heat and steam to pass overheadDAll of the above
单选题When fighting a fire with a portable dry chemical fire extinguisher,the stream should be directed().Aover the top of the flamesBoff a bulkhead into the fireCin front of the fireDat the base of the fire
单选题When fighting fires in spaces containing bottles of LPG (liquefied petroleum gas),you should ().Aattempt to isolate the fire from the LPGBcool the bottles or remove them from the fire areaCsee that the valves on all LPG bottles are closedDplace insulating material over the bottles