Bonding cables are used during cargo transfer to ______.A.provide safe electrical power connection to barge equipmentB.keep the vessel from surging excessivelyC.prevent an accidental discharge of static electricityD.secure the cargo hose to a hatch when loading overall

Bonding cables are used during cargo transfer to ______.

A.provide safe electrical power connection to barge equipment

B.keep the vessel from surging excessively

C.prevent an accidental discharge of static electricity

D.secure the cargo hose to a hatch when loading overall


相关考题:

The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the ______.A.bridge control panelB.disconnect linksC.main switchboardD.governor relay box

Cargo transfer operations on a tank vessel need NOT be stopped when ______.A.a tug comes alongside while the tanker is loading grade D and E cargoesB.a large,fresh oil spill is discovered immediately adjacent to the side of the tankerC.there is an electrical storm in the vicinityD.there is a fire on the dock or on a nearby vessel

The original Bill of Lading,once signed by the Master,is NOT ______.A.a receipt and proof that goods have been received on boardB.surrendered to the customs agency of the country where the cargo is dischargedC.used to transfer ownership of the cargo while the ship is enrouteD.proof of title or ownership of the cargo

The sign used to caution persons approaching the gangway of a tank barge during cargo transfer reads ______.A.Warning,Keep Off,Stay ClearB.Danger,Do Not BoardC.Warning,No Smoking,No Open Lights,No VisitorsD.Dangerous Cargo Being Transferred

A bonding cable should be connected for cargo operations aboard a tank vessel as soon as the ______.A.Cargo has been loaded or dischargedB.Cargo hose is connectedC.Cargo pumps are startedD.Vessel is ready to handle cargo

To allow for the rise or fall in tide and for change in draft of a tanker during cargo transfer,cargo hoses must be suspended with ______.A.Slings or saddles placed at 25-foot(8 meter)intervalsB.Enough slack in their bightC.Topping lifts and runners tied off to winchesD.All of the above

What is NOT required to be contained in the oil transfer procedures ________.A.A line diagram of the vessel's oil transfer pipingB.The number of persons on duty during oil transfer operationsC.Any special procedures for topping off tanksD.The location and capacity of all fuel and cargo tanks on the vessel

Do you require any further assistance? My ship is safe now and no assistance is necessary. This VHF communication generally takes place during ______.A.salvage operationB.cargo dischargingC.bunkeringD.towing operation

CO2 and Halon extinguishers are used for electrical fire, as well as ()fire.A、commonB、oilC、electricalD、chemical

()is best for electrical fire.A、Dry extinguisherB、Power extinguisherC、A+BD、CO2 extinguisher

A company has had problems with their HVAC system being able to cool their datacenter as they have grown.  Which of the following could BEST be used to help reduce the load on the HVAC system?()A、 Replacing the CAT5 cables with CAT6 cablesB、 Replacing traditional racks with water cooled racksC、 Turning off non-critical application servers during non-business hoursD、 Taking the second power supplys out of non-critical servers

单选题The purpose of a preventer as it is used on a conventional yard and stay cargo rig is to().Aallow greater than normal loads to be handled by the gearBact as an inboard guy in the event the inboard guy parts during cargo handlingCassist the outboard guy in supporting stresses during cargo handlingDprevent the inboard guy from parting due to stresses during cargo handling

单选题What does the article indicate about ECV-12?AIt will replace the regional electrical grid.BIt lies 400 miles from the nearest road system.CIt is based on a power station in Britain.DIt will send out power via underground cables.

单选题There are two disadvantages to CO2 pump as a firefighting agent. One of these is the limited quantity available,and the other is().Athe lack of cooling effect on heated materialsBthat it cannot be used in a dead ship situation with no electrical power to the CO2 pumpCthat it breaks down under extreme heat to form poisonous gasesDthere is no effect on a class A fire even in an enclosed space

单选题The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the ().Abridge control panelBdisconnect linksCgovernor relay boxDmain switchboard

单选题Cargo transfer operations on a tank vessel need NOT be stopped when().Aa tug comes alongside while the tanker is loading gradeBand E cargoes B. a large,fresh oil spill is discovered immediately adjacent to the side of the tankerCthere is an electrical storm in the vicinityDthere is a fire on the dock or on a nearby vessel

单选题Which statement concerning reserve sources of energy for GMDSS is FALSE().AWhile the ship is at sea,there must be available at all times a supply of electrical energy sufficient to operate the radio installations and to charge any batteries used as part of a reserve source of energyBBoth the VHF and MF/HF installations must be simultaneously suppliedCA means of ensuring a continuous supply of electrical power must be provided to all GMDSS equipment that could be affected by an interruption in powerDIf a UPS or equivalent is used to supply power to the ship's GPS receiver or other source of positional information,a means must be provided to ensure the continuous supply of the information in the event of a failure to the ship's main or emergency source of power

单选题Why is a warning sign displayed at the gangway or access point of a barge during cargo transfer().ATo keep visitors away from the bargeBTo prohibit smokingCTo prohibit open lightsDAll of the above

单选题A company has had problems with their HVAC system being able to cool their datacenter as they have grown.  Which of the following could BEST be used to help reduce the load on the HVAC system?()A Replacing the CAT5 cables with CAT6 cablesB Replacing traditional racks with water cooled racksC Turning off non-critical application servers during non-business hoursD Taking the second power supplys out of non-critical servers

单选题Bonding cables are used during cargo transfer to().Aprovide safe electrical power connection to barge equipmentBkeep the vessel from surging excessivelyCprevent an accidental discharge of static electricityDsecure the cargo hose to a hatch when loading overall

单选题On tank vessels equipped with power operated cargo tank valves, the type of power operator most commonly used is ().AhydraulicBelectricCsteamDdiesel

单选题Hoses used for cargo transfer operations must be tested and inspected at specified intervals by().Aa representative of the Captain of the PortBthe operator of the vessel or facilityCa representative of the National Cargo BureauDlow inert gas temperature

单选题Hoses used for cargo transfer operations must be tested abdinspected at specified intervals by ().Aa representative of the Captain of the PortBthe operator of the vessel or facilityCa representative of the National Cargo BureauDa representative of the American Bureau of Shipping

单选题Cargo transfer operations on a tanker need NOT be stopped when().Aa tug comes alongside while the tanker is loading grade D and E cargoesBa large,fresh oil spill is discovered immediately adjacent to the side of the tankerCthere is an electrical storm in the vicinityDthere is a fire on the dock or on a nearby vessel

单选题According to regulations,a cargo hose used for transferring liquefied gases must have a bursting pressure of().A5 times the maximum working pressure on the hose during cargo transferBone half the designed working pressureC4 times the pressure of the cargo pump used for transferringD5 times the minimum working pressure on the hose during cargo transfer

单选题The sign used to caution persons approaching the gangway of a tank barge during cargo transfer reads().AWarning,Keep Off,Stay ClearBDanger,Do Not BoardCWarning,No Smoking,No Open Lights,No VisitorsDDangerous Cargo Being Transferred

单选题When possible,what should be the FIRST step in combating a fire on deck resulting from a cargo overflow or a leaking cargo line?()ABlanket the cargo spill with foamBPrevent the spread of fire with a foam damCApply CO2 on burning fuel at its sourceDShut off the transfer of cargo